At this location, attach a single gang box to a wall stud at a center height 
of normal wall outlets. Make sure the single gang box extends past the 
wall stud and into the room so it will be flush with the sheetrock when it 
is applied. Run the Red and Black shielded audio cables (included in the 
AWPRX) from the master unit location to the AWP location. Secure the 
audio cables with a loose knot after they have been pulled through the 
single gang box. Secure the cables at the master. Label all cables. 

 

Power Amp Installation – Stereo Upgrade 

Run the MS7XSC 
cable from the dmc1H 
or dmc1HC wall 
housing to the remote 
power amplifier.  
Run the MS5XSC 
cable from the remote amplifier 
to each volume control. From 
each volume control, run the 
MS2SXSC to each respective speaker as shown in figure 
11.  
The remote power amplifier should be located in a closet 
or utility closet and should be located within 6 feet of a 
standard NEMA 5-15R 120VAC receptacle. Install a 1-
gang and a 2-gang box at the location for the remote 
amplifier on a stud. Allocate the 1-gang and 2-gang 
boxes relative to one another as shown in figure 12. Run 
all MS5XSC cables from the volume controls to the 
remote amplifier’s 2-gang box.  
Run the MS7XSC cable from the dmc1 to the remote 
amplifier’s 1-gang box. The remote amplifier is designed 
to mount over the 1-gang and 2-gang boxes on a single stud. Note: The 
speaker cables CANNOT be located in the same gang box used for 
120VAC wiring. 

Figure 11 - Power amp wiring 

Figure 12 - Power 

amp installation 

Dmc1H

 

 

MS7XSC

Содержание dmc1 Finish-Out

Страница 1: ...dmc1 2861 Congressman Lane Dallas Texas 75220 800 877 6631 www mssystems com Page 1 dmc1 Rough In Instructions...

Страница 2: ...of experience in the design and manufacture of precision acoustical equipment for the home To ensure that the homeowners receives the high quality music and voice reproduction that the system is desig...

Страница 3: ...ce Read ALL safety and operating instructions before installing the dmc1 Adhere to all warnings on the dmc1 and in these instructions Follow all operating and installation instructions CAUTION These i...

Страница 4: ...1 master or room stations in an outside wall Do Not expose the dmc1 to moisture Doing so can create fire or shock hazards and impair the warranty Do not place the dmc1 master or room stations in any w...

Страница 5: ...the entire system LABEL all wiring runs Connecting the wires to the dmc1 master room station or door stations incorrectly may result in system damage Run a single cable from the master unit location...

Страница 6: ...withstand the extreme heat and moisture DO NOT install room stations underneath cabinets or over counter tops DO NOT install room stations in stud cavities with other wiring or appliances DO NOT insta...

Страница 7: ...r Tape measure Level Installing the Wall Housing DMC1H DMC1HC Locate wall housing DMC1H or DMC1HC Combo Position back side of wall housing flush with back of 2X4 stud approx imately 52 high for DMC1H...

Страница 8: ...n figure 4 For the DMC1HC combo wall housing have a qualified electrician loop a power wire from the TE5C transformer enclosure to the TE2C transformer enclosure following the same procedure described...

Страница 9: ...ther electronic devices Speakers At each room station location nail or screw the DMC1HR mounting ring 52 above the floor as shown in figure 8 From the master wall housing run CAT5 cable to each remote...

Страница 10: ...metal enclosure on the cable about 50 above the floor porch so the brick mason can flush and level it in the brick wall as shown in figure 10 If wood vinyl or aluminum siding is used secure surface m...

Страница 11: ...mplifier Run the MS5XSC cable from the remote amplifier to each volume control From each volume control run the MS2SXSC to each respective speaker as shown in figure 11 The remote power amplifier shou...

Страница 12: ...option is a dry contact closure provided by the dmc1 master This dry contact is rated 24V at 4 Amps The sample applications below represent some uses of this option However only one application can be...

Страница 13: ...rom the DMC1H or DMC1HC housing location to the security control panel Setup the security panel to receive a normally open dry contact for panic operation Refer to programming procedures accompanying...

Страница 14: ...dmc1 2861 Congressman Lane Dallas Texas 75220 800 877 6631 www mssystems com Page 14 Notes...

Страница 15: ...ired product freight prepaid within the continental United States ANY PRODUCT RETURNED TO M S SYSTEMS WITHOUT A RAN NUMBER WILL BE REFUSED This limited warranty is in lieu of any other warranties expr...

Страница 16: ...dmc1 2861 Congressman Lane Dallas Texas 75220 800 877 6631 www mssystems com Page 16 115996...

Отзывы: