6
7
M P S 1 6 2 0 P P R O F E S S I O N A L M O N I T O R
M P S 1 6 2 0 P P R O F E S S I O N A L M O N I T O R
5. INPUT & CONTROLS
A. Balanced XLR & 6,3 mm Jack Input
B. Unbalanced RCA input
C
System & tweeter level trim.
D Input level selector
E. Variable gain volume trim
F.
Bass response Normal / Full range
G 80Hz High Pass filter in/out switch
H. Main Power Switch
I. Fuse holder
J.
Main Voltage selector
K. Main Power socket
A
Balanced Input XLR or 6.3 mm Jack.
Use balanced connection to professional mixing equipment, sound-
cards & studio monitor controllers.
B
Unbalanced Input RCA.
Use unbalanced connection to Hi-Fi preamps, TV set, or general small
portable sound devises.
C
System & Tweeter trim
System and tweeter trim pots for “output level” calibration.
Using the trim pots will impact the factory preset frequency response
and output level, and shall only be calibrated by qualified engineers.
D
Input sensitivity switch.
Use switch position “Fixed” when connecting to unbalanced devises.
Use switch Position “+4dBu” when connecting to professional bal-
anced equipment.
Use switch position “Variable” to activate gain level control, for fine
tuning “system output level”.
E
Variable gain control.
The The variable gain control can be used when operating 1620P with
subwoofers, or in setups with other speakers having higher or lower
output levels.
The variable gain control offer +/- 6dB gain control relative to the
+4dBu REF level.
F - G
Bass Response & High-Pass filter.
Set Bass Response & High Pass Filter switch properly when operating
the MPS1620P either as a stand-alone full range speaker, or in setups
with subwoofers and Bass management controllers.
See section “MODES OF OPERATION” for further instructions.
H
Main Power on/off
Turns the system on / off.
Status LED are present on front and back of speaker.
I
Fuse holder.
Fuse type T2AL 250Volt for 110 / 120 Volt
Fuse type T1AL 250 volt for 220 / 240 Volt
Caution! Always disconnect power cord before changing fuse,
Replace fuse only with same type.
J
Voltage selector 115 / 230 Volt.
Caution!
Always disconnect power cord and change fuse to correct
value before changing input voltage.
K
Main Power socket
Use the included power chord for the main power connection.