FDMB - Fire damper

TPM 164/22

Sizes listed within the maximum/minimum sizes can be manufactured on request.

A x B

[mm]

Damper blade

overlaps

Weight

Effective

area Sef

[m

2

]

Actu.

mech.

Mech.

contr.

A x B

[mm]

Damper blade

overlaps

Weight

Effective

area Sef

[m

2

]

Actu.

mech.

Mech.

contr.

a

[mm]

c

[mm]

mech

[kg]

servo

[kg]

a

[mm]

c

[mm]

mech

[kg]

servo

[kg]

400 x

710

-

295

18,8

20,3

0,2168

BFN

M2

500 x 1000

140

440

26,5

29,3

0,4090

 BF

M4

750

15

315

19

21,8

0,2307

BF

M3

550 x

125

-

-

9,3

10,5

0,0350

BFL

M1

800

40

340

20,3

23,1

0,2481

140

-

5

9,7

10,9

0,0428

900

90

390

21,9

24,7

0,2829

150

-

15

9,9

11,1

0,0480

1000

140

440

23,6

26,4

0,3177

M4

160

-

20

10,4

11,6

0,0364

450 x

125

-

-

8,4

9,6

0,0283

BFL

M1

180

-

30

10,7

11,9

0,0463

140

-

5

8,7

9,9

0,0346

200

-

40

11,1

12,3

0,0563

150

-

15

8,9

10,1

0,0388

225

-

52,5

11,6

12,8

0,0687

160

-

20

9,3

10,5

0,0374

250

-

65

12,1

13,3

0,0812

180

-

30

9,6

10,8

0,0456

280

-

80

12,6

13,8

0,0961

200

-

40

9,9

11,1

0,0538

300

-

90

13,4

14,6

0,1061

225

-

52,5

10,4

11,6

0,0641

315

-

97,5

13,7

14,9

0,1135

250

-

65

10,8

12

0,0744

355

-

117,5

14,9

16,1

0,1335

280

-

80

11,4

12,6

0,0867

400

-

140

15,9

17,4

0,1559

BFN

M2

300

-

90

12

13,2

0,0949

450

-

165

16,9

18,4

0,1808

315

-

97,5

12,2

13,4

0,1011

500

-

190

17,9

19,4

0,2057

355

-

117,5

13,3

14,5

0,1175

550

-

215

18,9

20,4

0,2306

400

-

140

14,3

15,5

0,1360

560

-

220

19,1

20,6

0,2356

450

-

165

15,2

16,7

0,1445

BFN

M2

600

-

240

20

21,5

0,2555

500

-

190

16

17,5

0,1644

630

-

255

20,4

23,2

0,2704

BF

550

-

215

17

18,5

0,1843

650

-

265

20,8

23,6

0,2804

560

-

220

17,1

18,6

0,1883

700

-

290

21,8

24,6

0,3053

600

-

240

17,9

19,4

0,2042

710

-

295

22

24,8

0,3103

630

-

255

18,4

19,9

0,2161

750

15

315

22,3

25,1

0,3302

M3

650

-

265

18,7

20,2

0,2241

800

40

340

23,9

26,7

0,3551

700

-

290

19,5

22,3

0,2440

BF

900

90

390

25,7

28,5

0,4049

710

-

295

19,7

22,5

0,2480

560 x

125

-

-

9,4

10,6

0,0356

BFL

M1

750

15

315

20

22,8

0,2639

M3

140

-

5

9,8

11

0,0436

800

40

340

21,5

24,3

0,2838

150

-

15

10

11,2

0,0489

900

90

390

23,2

26

0,3236

160

-

20

10,5

11,7

0,0371

1000

140

440

24,8

27,6

0,3634

M4

180

-

30

10,8

12

0,0472

500 x

125

-

-

8,8

10

0,0316

BFL

M1

200

-

40

11,2

12,4

0,0574

140

-

5

9,2

10,4

0,0387

225

-

52,5

11,7

12,9

0,0701

150

-

15

9,4

10,6

0,0434

250

-

65

12,2

13,4

0,0828

160

-

20

9,8

11

0,0419

280

-

80

12,8

14

0,0980

180

-

30

10,2

11,4

0,0511

300

-

90

13,3

14,5

0,1082

200

-

40

10,5

11,7

0,0603

315

-

97,5

13,8

15

0,1158

225

-

52,5

11

12,2

0,0718

355

-

117,5

15

16,2

0,1361

250

-

65

11,4

12,6

0,0834

400

-

140

16,1

17,6

0,1590

BFN

M2

280

-

80

12

13,2

0,0972

450

-

165

17,1

18,6

0,1844

300

-

90

12,7

13,9

0,1064

500

-

190

18,1

19,6

0,2098

315

-

97,5

13

14,2

0,1133

550

-

215

19,1

20,6

0,2352

355

-

117,5

14,1

15,3

0,1318

560

-

220

19,3

20,8

0,2403

400

-

140

15,1

16,3

0,1525

M2

600

-

240

20,2

21,7

0,2606

450

-

165

16,1

17,6

0,1626

BFN

630

-

255

20,5

23,3

0,2758

BF

500

-

190

17

18,5

0,1850

650

-

265

21

23,8

0,2860

550

-

215

17,9

19,4

0,2074

700

-

290

22

24,8

0,3114

560

-

220

18,2

19,7

0,2119

710

-

295

22,2

25

0,3165

600

-

240

18,9

20,4

0,2298

750

15

315

22,4

25,2

0,3368

M3

630

-

255

19,5

21

0,2433

800

40

340

24,2

27

0,3622

650

-

265

19,8

22,6

0,2522

BF

600 x

140

-

5

10,2

11,4

0,0469

BFL

M1

700

-

290

20,9

23,7

0,2746

150

-

15

10,5

11,7

0,0526

710

-

295

21

23,8

0,2791

160

-

20

10,9

12,1

0,0400

750

15

315

21,2

24

0,2970

M3

180

-

30

11,3

12,5

0,0510

800

40

340

22,8

25,6

0,3194

200

-

40

11,7

12,9

0,0619

900

90

390

24,6

27,4

0,3642

225

-

52,5

12,3

13,5

0,0756

Содержание FDMB

Страница 1: ...andik mandik cz Manufacturer MANDIK UK Ltd 130 Aztec West Bristol BS32 4UB United Kingdom Tel 44 117 4526376 E Mail help mandik co uk Authorized representative FDMB Fire damper Technical Documentation...

Страница 2: ...t of installations 22 Installation in solid wall construction 23 Installation outside solid wall construction 25 Installation in gypsum wall construction 27 Installation outside gypsum wall constructi...

Страница 3: ...mechanism back spring Closing spring is released either by pushing of the button or by thermal fuse The back spring of the actuating mechanism is started when the thermoelectrical starting mechanism B...

Страница 4: ...which actuates the shutting device after the nominal start temperature 72 C has been reached Automatic initiation of the shutting device is not activated if the temperature does not exceed 70 C In ca...

Страница 5: ...rotection IP 67 Working temperature 25 C 120 C Limit switch G905 300E03W1 This limit switchis possibleto connect infollowing two versions CUT OFF if the arm is moving connect wire 1 2 SWITCH ON if the...

Страница 6: ...damper blade into the breakdown position CLOSED The time of displacing the blade from the position OPEN to the position CLOSED takes maximum 20 sec In case that the power supply is restored again the...

Страница 7: ...ax 8 3 A 5 ms Protection class II III Degree of protection IP 54 Running time motor spring return 60 s 20 s Ambient temperature normal duty safety duty non operating temperature 30 C 55 C The safe pos...

Страница 8: ...lass II III Degree of protection IP 54 Running time motor spring return 60 s 20 s Ambient temperature normal duty safety duty non operating temperature 30 C 55 C The safe position will be attained up...

Страница 9: ...egree of protection IP 54 Running time motor spring return 120 s 16 s Ambient temperature normal duty safety duty non operating temperature 30 C 50 C The safe position will be attained up to max 75 C...

Страница 10: ...ing mechanism BAT If the thermal fuse Tf1 breaks for a temperature close to the fire damper it is necessary to replace the actuating mechanism Thermoelectric starting mechanism BAT is integral part of...

Страница 11: ...ired with MANDIK control systems OVERRIDE MDCM 6 5 4 3 2 1 L N N L MOTOR POWER COMMS S S F1 S5 S6 S4 S3 S2 S1 COMMS OPEN CLOSED COMMAND L L N L S90C CONTROLLER S90 mounted in an addressablesmoke contr...

Страница 12: ...Hole for camera 130 123 375 A 38 X 14 A 160 or B 160 X 23 AxB 500x400 X 36 AxB 500x400 A 60 B B 60 A 60 B X B 60 60 X 2 A X 60 X 2 1 Damper casing 2 Actuating mechanism 3 Damper blade 4 Inspection hol...

Страница 13: ...e specified in chapter Technical parameters see pages 14 to 19 Values a and c has to be respected when projecting related air conditioning ducts Flange of Damper OPERATORS SIDE Flanges of dampers are...

Страница 14: ...0 0041 BFL M1 630 255 12 3 13 5 0 0586 110 4 9 6 1 0 0050 650 265 12 5 13 7 0 0608 125 5 1 6 3 0 0065 700 290 13 1 14 3 0 0662 140 5 5 3 6 5 0 0080 710 295 13 3 14 5 0 0673 150 15 5 4 6 6 0 0089 750...

Страница 15: ...0 0937 600 240 12 7 13 9 0 0759 600 240 13 7 15 2 0 1016 BFN 630 255 13 1 14 3 0 0804 630 255 14 2 15 7 0 1075 650 265 13 3 14 5 0 0833 650 265 14 4 15 9 0 1115 700 290 14 15 5 0 0907 BFN 700 290 15 2...

Страница 16: ...0 1148 BFN 550 215 15 1 18 1 0 1403 560 220 14 2 15 7 0 1173 560 220 15 3 18 3 0 1433 600 240 14 8 16 3 0 1272 600 240 15 9 18 9 0 1554 630 255 15 2 16 7 0 1347 630 255 16 4 19 4 0 1645 650 265 15 4...

Страница 17: ...2042 710 295 22 24 8 0 3103 630 255 18 4 19 9 0 2161 750 15 315 22 3 25 1 0 3302 M3 650 265 18 7 20 2 0 2241 800 40 340 23 9 26 7 0 3551 700 290 19 5 22 3 0 2440 BF 900 90 390 25 7 28 5 0 4049 710 29...

Страница 18: ...8 0 0798 650 265 24 1 26 9 0 3648 250 65 13 1 14 3 0 0942 700 290 25 4 28 2 0 3972 280 80 13 7 14 9 0 1116 710 295 25 8 28 6 0 4037 300 90 14 5 15 7 0 1231 710 x 150 15 11 7 12 9 0 0627 BFL M1 315 97...

Страница 19: ...13 9 0 0710 BFL M1 355 117 5 20 2 21 7 0 2273 160 20 13 1 14 3 0 0546 400 140 21 6 23 1 0 2654 180 30 13 7 14 9 0 0696 450 165 23 24 5 0 3078 200 40 14 1 15 3 0 0845 500 190 24 3 27 1 0 3502 BF 225 52...

Страница 20: ...ected according to the certified install ation method see pages 22 to 34 During the installation and plastering process the control mechanism must be protected covered against damage and pollution The...

Страница 21: ...and the damper blade labelled with BUILT IN EDGE on the protective covering must be protected with fire fighting insulation If damper is installed outside a construction it is necessary to use reinfor...

Страница 22: ...Ultimate Protect Ablative Coated Batt EI 90 ve i o S 25 26 In gypsum wall construction Mortar or gypsum EI 120 ve i o S 27 Ablative Coated Batt 100mm EI 90 ve i o S EI 60 ve i o S 28 75 Ablative Coat...

Страница 23: ...inimum density 670 kg m 4 Fixing profile with threaded rod see pages 35 to 37 5 Duct Solid wall construction mortar or gypsum EIS 120 X X 100 50 150 50 150 100 B min B 100 max B 300 A min A 100 max A...

Страница 24: ...ladding boards not part of the damper but must be used as part of the penetration filling It can be ordered from MAND K as an accessory e g PROMATECT MST min density 750 kg m3 for AxB 500x400 th 10 mm...

Страница 25: ...ed separately for each installation case see page 45 Outside solid wall construction ISOVER Ultimate Protect Ablative Coated Batt EIS 90 1 FDMB 2 Solid wall construction 3 Ablative Coated Batt e g Fir...

Страница 26: ...EN 1507 and DIN 24190 7 ISOVER Protect BSK glue apply on the insulation and stick it to the fire separation construction 8 Fire resistant mastic fill the gap on both sides of the fire separation const...

Страница 27: ...ing profile with threaded rod see pages 35 to 37 5 Duct X X 100 50 150 Installation in gypsum wall construction Gypsum wall construction mortar or gypsum EIS 120 B min B 100 max B 300 A min A 100 max...

Страница 28: ...CFS CT PROMASTOP CC or equivalent 5 Duct 6 Protective cladding boards not part of the damper but must be used as part of the penetration filling It can be ordered from MAND K as an accessory e g PROMA...

Страница 29: ...OMATECT MST min density 750 kg m3 for AxB 500x400 th 10 mm for AxB 500x400 th 15 mm or equivalent 7 Fire resistant mastic fill the gap on both sides of the fire separation construction and around the...

Страница 30: ...installation always VRM2 B is not a part of the Fire damper and must be ordered separately for each installation case see page 45 1 FDMB 2 Gypsum wall construction 3 Ablative Coated Batt e g Firestop...

Страница 31: ...4190 7 ISOVER Protect BSK glue apply on the insulation and stick it to the fire separation construction 8 Fire resistant mastic fill the gap on both sides of the fire separation construction and aroun...

Страница 32: ...threaded rod see pages 35 to 37 5 Duct Installation in solid ceiling construction Solid ceiling construction mortar or gypsum EIS 120 X X 150 50 150 50 150 150 A A A min A 100 max A 300 A B min B 100...

Страница 33: ...ed structure 25mm insulation EI 60 87 Gyproc FireLine 2 x 12 5 4400 60 40 44 39 97 Gyproc FireLine 2 x 12 5 4400 70 40 44 39 119 Gyproc FireLine 2 x 12 5 6000 92 45 47 40 173 Gyproc FireLine 2 x 12 5...

Страница 34: ...750 kg m3 for AxB 500x400 th 10 mm for AxB 500x400 th 15 mm or equivalent 10 Fire resistant mastic fill the gap on both sides of the fire separation construction and around the perimeter of penetrati...

Страница 35: ...157 96 192 M18 192 117 234 M20 245 150 300 Without anchor With anchor Possible examples of anchoring to the ceiling construction Follow the instructions of fixing specialist or installation company Wi...

Страница 36: ...Threaded rod M8 M20 3 Support HILTI MQ 41 or MQ 41 3 or equivalent 4 Bored plate HILTI MQZ L or equivalent 5 Washer for M8 M20 6 Nut M8 M20 max 50 Dimension elements of the suspension system acc to th...

Страница 37: ...Page 37 Version 2022 12 20 FDMB Fire damper TPM 164 22 Duct connection 1 FDMB 2 Connecting air duct 3 Extension piece if required 4 Damping pad or breakaway connection as DW 144 max 200...

Страница 38: ...ATA Pressure loss Pressure loss calculation Determination of pressure loss by using diagram 1 2 kg m3 p w2 2 p Pa presure loss w m s air flow speed in nominal damper section kg m3 air density coeffici...

Страница 39: ...761 710 1 645 3 918 2 720 2 062 1 496 1 284 1 055 0 947 0 881 0 749 750 1 630 3 865 2 682 2 032 1 475 1 264 1 037 0 931 0 866 0 736 800 1 612 3 808 2 640 1 999 1 445 1 241 1 018 0 913 0 849 0 721 900...

Страница 40: ...62 7 64 4 6 44 1 47 3 49 5 51 3 52 7 53 9 54 9 55 8 56 6 59 8 62 63 8 65 2 67 4 69 2 7 48 2 51 3 53 5 55 3 56 7 57 9 58 9 59 8 60 7 63 8 66 1 67 8 69 2 71 4 73 2 8 51 6 54 8 57 58 8 60 2 61 4 62 4 63...

Страница 41: ...ents entering the interior of damper casing lower sheet of mechanics lock holder 1 lock lever 2 lock spring 8 dia stopper pin mechanics pin 5 Inspection hole cover including the clip and fasteners if...

Страница 42: ...SED position Dampers are stored indoor in environment without any aggressive vapours gases or dust Indoor temperature must be in the range from 30 C to 50 C and maximum relative humidity 95 avoid cond...

Страница 43: ...he required device to the base plate of the damper The said facts must be recorded in the respective operation documentation of the damper record books of the damper fire logs etc and subsequently ade...

Страница 44: ...12 20 TPM 164 22 1 Damper 6 Fusible link 2 Mounting plate 7 Mechanics 3 Sealing cover 8 Actuator 4 Seal plates 9 Temperature sensor 5 Mounting plate cover 10 Sensor sticker Change of mechanical desig...

Страница 45: ...ge except glue K84 Reinforcing frame VRM2 B Fixing reinforcing frame VRM2 B to the damper casing Installation procedure 1 Apply K84 glue over the entire surface 2 Attach the frame parts to the damper...

Страница 46: ...sition Release of the locking mechanism can be achieved manually or automatically by applying the supply voltage It is recommended to provide periodical checks maintenance and service actions on Fire...

Страница 47: ...he function checks the dampers should be moved to CLOSED position with the fan off or with closed regulation valve situated between the fan and the fire damper Before putting the dampers into operatio...

Страница 48: ...80 With actuating mechanism BF 230 TN BFL BFN 230 T voltage AC 230 V 40 With actuating mechanism BF 24 TN BFL BFN 24 T voltage AC DC 24 V 50 design Reinforcing frame VRM2 B damper placement outside wa...

Страница 49: ...ual product information see www mandik co uk MAND K a s Dob sk 550 267 24 Hostomice Czech Republic Tel 420 311 706 742 E Mail mandik mandik cz Manufacturer MANDIK UK Ltd 130 Aztec West Bristol BS32 4U...