POWER REQUIREMENT
230VAC, Single Phase, 50/60Hz +N +PE (or)
110VAC, Single Phase, 50/60Hz +N +PE
Supply should be connected only through a CVT of 1KVA capacity and then through an
UPS of minimum 1KVA capacity with AVR (Automatic Voltage Regulator) circuit using
a CE certified Two Pole, Type C, 6A MCB. Proper Earthing must be provided. Also
ensure that live phase is on the right side
point of the wall socket.
Neutral to Line Voltage should be 230V AC ±10% (or) 110V AC ±10%
Line to Earth voltage should be 230V AC ±10% (or) 110V AC ±10%
Neutral to Earth leakage should be less than 3V AC
It is strongly recommended to use CVT & UPS (with AVR) for the aligner.
Note: For Laser Printer, separate power source should be used.