11.2 On Site Modifications
Option
Operations
Constant Pressure to Open
1. Move
GREY
wire from terminal
#3 →
#4
.
Wiring for Instant Stop
(on safety edge or device)
1. Remove
YELLOW
wire from Adv. Open Limit Switch and cap it.
2. Remove
BLUE
wire from pin
#4
on the Reversing Relay (RR) and cap it.
Adding a Time Delay on Reverse
(refer to Figure 41 below)
1.
Remove
YELLOW
wire from Adv. Open Limit Switch.
2.
Connect the
YELLOW
wire to one end of the Time Delay Module.
3.
From the other end of the Time Delay Module, reconnect
YELLOW
wire
to the Adv. Open Limit Switch.
Constant Pressure to Open and
Close – D1 Mode
1. B2 Mode → C2 Mode:
◦
Move
RED
wire from terminal
#7 →
#5
.
2. Constant Pressure to Open:
◦
Move
GREY
wire from terminal
#3 →
#4
.
3. Wiring for Instant Stop:
◦
Remove
YELLOW
wire from Adv. Open Limit Switch and cap it.
◦
Remove
BLUE
wire from pin
#4
on Reversing Relay (RR) and
cap it.