Installation Instructions

IMPORTANT INSTALLATION INSTRUCTIONS

 WARNING

TO REDUCE THE RISK OF SEVERE INJURY OR

DEATH TO PERSONS:

1. READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS.
2. Install   only   on   a   properly   operating   and   balanced   door.  A  door   that   is   operating

improperly could cause severe injury. Have qualified service personnel make repairs
to cables, spring assemblies and other hardware before installing the operator.

3. Remove   all   pull   ropes   and   remove,   or   make   inoperative,   all   locks   (unless

mechanically and/or electrically interlocked to the power unit) that are connected to
the door before installing the operator.

4. Installation of this door operator must be done by a qualified installer.
5. Verify that the operator is correct for type, size of door and frequency of use per the

operator specifications.

6. Install the door operator at least 8 feet (2,44 m) or more above the floor if the operator

has exposed moving parts. Covers or guarding, provided by the manufacturer, must
be installed when the operator is mounted less than 8 feet (2,44 m) above the floor.

7. Do not connect the door operator to the source of power until instructed to do so.

8.

Locate the control station: (a) within sight of the door, (b) at a minimum height of

5 feet (1,5 m) above floors, landings, steps or any other adjacent walking surface so
small children cannot reach it, and (c) away from all moving parts of the door.

9. Install the Entrapment Warning Placard next to the control station in a prominent

location.

10. For products having a manual release, instruct the end user on the operation of the

manual release.

11. If you have any questions about the safety of the door operating system, do not install

the operator, contact Manaras-Opera at 

1-800-361-2260

.

For technical support, please call 

1-800-361-2260

 or visit 

www.manaras.com

 for more information

Содержание Rapido RSH

Страница 1: ...Heavy Duty Heavy Duty Operator Operator For fast doors with high performance and speed managing requirements For fast doors with high performance and speed managing requirements RapidoTM RSH RSH READ...

Страница 2: ...Switch Functionality 5 2 3 Limit Switch Adjustment Using Manual Hand Chain 6 2 4 Low Voltage Controls and High Voltage Power Connections 7 2 5 Main Power Supply Connection 7 3 Electrical Drawings 8 3...

Страница 3: ...Install the door operator at least 8 feet 2 44 m or more above the floor if the operator has exposed moving parts Covers or guarding provided by the manufacturer must be installed when the operator i...

Страница 4: ...PUT SPEED 88 RPM NET WEIGHT Operator only 96 Lbs 44 Kg STANDARD WIRING TYPE C2 momentary contact to open stop and constant pressure to close APPLICATION Ultra high end heavy duty v belt drive for sect...

Страница 5: ...usted accordingly to stop door in fully open position Close Limit Switch and Advanced Close Limit Switch Close Limits are not present on operators with an ECB In it s place the microprocessor has a bu...

Страница 6: ...ges in the slots of both cams Advanced Close Limit 1 Using the hoist manually lower the door to approx 6 above the ground 2 Pull the cam retaining bracket from the Close side see Figure 2 and rotate C...

Страница 7: ...panel as shown in Figure 3 2 Route all low voltage control wires as shown in Figure 3 KEEP LOW VOLTAGE WIRES SEPARATE FROM LINE VOLTAGE WIRES 3 USE COPPER CONDUCTORS ONLY 2 5 Main Power Supply Connec...

Страница 8: ...8 3 Electrical Drawings 3 1 1 Phase 120VAC Rapido Operator and BOARD 070 For technical support please call 1 800 361 2260 or visit www manaras com for more information Figure 4 EDWG14070VFD03...

Страница 9: ...9 3 2 1 Phase 240VAC Rapido Operators and BOARD 070 For technical support please call 1 800 361 2260 or visit www manaras com for more information Figure 5 EDWG14070VFD04...

Страница 10: ...itten specifications are not properly applied by the Buyer when selecting the equipment If our written instructions for installation and wiring of the electrical connections have not been followed If...

Страница 11: ...11 Notes For technical support please call 1 800 361 2260 or visit www manaras com for more information...

Страница 12: ...Reg T M of 9141 0720 Qu bec Inc ADD1011 REV 8 2016 08 26...

Отзывы: