Application: To control the power flow, between to
two more power producing plants. The plants are
not allowed to fed or heat each other.
Function 1: adjust the power flow or decoupling the
plants. If it is over the limit.
Function 2: Protecting generator, by tripping the
alternator circuit breaker.
Negative sequence
ANSI-code: 46
Application: to protect the alternator against imbal-
ance loading of the phases or loss of phase. If there
is a difference between the phases, this will create a
negative rotating vector system in the alternator,
which will produce harmonics and course heating of
the rotor.
Function: Protecting generator, by tripping the gen-
erator circuit breaker.
Field failure protection
ANSI-code: 40
Application: To protect the synchronous generator
against operation outside the stable operation area
due to loss of excitation. When partial or complete
loss of excitation occurs on a synchronous machine
it obtaining reactive power, it flows from the system
into the machine and the apparent impedance as
viewed from the machine terminals, goes into the
negative X region in the R-X diagram.
The Field failure system detects the low or under
impedance condition. Max. 15% 2sec
Function: Protecting generator, by tripping the alter-
nator circuit breaker.
Alternator differential protection
ANSI-code: 87G
Differential protection of alternator compares cur-
rent in two measuring points, the star point with the
current at the bus bar; it is a fast and selective form
of protection. Faults lying within the protected zone
are clearly and rapidly detected and reacted by
switching the alternator of to limit the fault damage.
The type of faults which occurring is insulation fail-
ure.
Faults between stator and windings
Stator earth faults.
Ground faults and faults between phases outside
the alternator but within the protected zone, at the
terminal or on external connections.
Function: Protecting alternator, by tripping the alter-
nator circuit breaker.
Temperature monitoring
IEC/EN 60751
Protection that detects abnormal temperature build
up inside the alternator windings. The measurement
is done by sensors placed inside the stator winding
in the slots. There at two types
PT 100 Ohm normal 2 x 3 pcs with three Leeds pr.
Sensor. (Base Module)
PT1000 Ohm normal 2 x 3 pcs with three Leeds pr.
Sensor (SaCos One)
Thermistors or thermocouples 2 x 3 pcs. whit two
leads for each sensor.
Alternator bearing protection can also be done by a
PT100 / PT1000 Sensor
Synchronising protection
ANSI-code: 79
The synchronising protection is to protect the gen-
erator set when synchronising with the grid or other
rotating GenSets. To do this it is necessary to
detect the Phase angel position and acceleration,
the phase angel must not be more than 2 deg.
Voltage difference, max 2%
Frequency difference, max 100mHz, min 98%, max
102%
To determine the max. acceptable tolerance, where
the switching can be done safely.
Function: Protecting alternator, by blocking the
switching on of the alternator circuit breaker.
Surge arrestors
IEC 60871-1, IEEE18, NEMA CP-1, VDE 0560 part
410, CIGRE 13.02
Is installed to protect the alternator insulation and
electronics against lightning and bad synchronisa-
tion, and in rush peaks from transformers and large
consumers. To do this, it is necessary to mount the
arrestors direct at or near to the alternator (within a
few meters from the terminals), the earth connec-
MAN Diesel & Turbo
B 17 00 0
Power Management - Alternator protection
3700383-8.2
Page 2 (6)
L23/30DF, L28/32DF, V28/32S, L28/32S, L28/32H, L27/38S, L27/38, L23/30S,
L23/30H, L21/31S, L21/31, L16/24S, L16/24
2015.11.17
Содержание L23/30DF
Страница 1: ...L27 38S Project Guide Power Plant Four stroke GenSet...
Страница 2: ......
Страница 8: ......
Страница 9: ...MAN Diesel Turbo I 00 Introduction Page 1 1 I 00 Introduction 2018 04 13 en...
Страница 10: ......
Страница 14: ......
Страница 16: ......
Страница 20: ......
Страница 31: ...MAN Diesel Turbo D 10 General information Page 1 1 D 10 General information 2018 04 13 en...
Страница 32: ......
Страница 40: ......
Страница 42: ......
Страница 46: ......
Страница 48: ......
Страница 50: ......
Страница 59: ...MAN Diesel Turbo B 10 Basic diesel engine Page 1 1 B 10 Basic diesel engine 2018 04 13 en...
Страница 60: ......
Страница 68: ......
Страница 69: ...Cross section MAN Diesel Turbo 1665740 7 3 Page 1 1 Cross section B 10 01 1 L27 38S L27 38 2014 11 18...
Страница 70: ......
Страница 72: ......
Страница 74: ......
Страница 76: ......
Страница 82: ......
Страница 84: ......
Страница 85: ...MAN Diesel Turbo B 11 Fuel oil system Page 1 1 B 11 Fuel oil system 2018 04 13 en...
Страница 86: ......
Страница 104: ......
Страница 114: ......
Страница 118: ......
Страница 126: ......
Страница 128: ......
Страница 130: ......
Страница 134: ......
Страница 137: ...MAN Diesel Turbo B 12 Lubricating oil system Page 1 1 B 12 Lubricating oil system 2018 04 13 en...
Страница 138: ......
Страница 142: ......
Страница 173: ...MAN Diesel Turbo B 13 Cooling water system Page 1 1 B 13 Cooling water system 2018 04 13 en...
Страница 186: ......
Страница 192: ......
Страница 198: ......
Страница 202: ......
Страница 204: ......
Страница 207: ...MAN Diesel Turbo B 14 Compressed air system Page 1 1 B 14 Compressed air system 2018 04 13 en...
Страница 210: ......
Страница 216: ......
Страница 217: ...MAN Diesel Turbo B 15 Combustion air system Page 1 1 B 15 Combustion air system 2018 04 13 en...
Страница 218: ......
Страница 224: ......
Страница 226: ......
Страница 227: ...MAN Diesel Turbo B 16 Exhaust gas system Page 1 1 B 16 Exhaust gas system 2018 04 13 en...
Страница 228: ......
Страница 252: ......
Страница 256: ......
Страница 269: ...MAN Diesel Turbo B 17 Speed control system Page 1 1 B 17 Speed control system 2018 04 13 en...
Страница 270: ......
Страница 272: ......
Страница 282: ......
Страница 284: ......
Страница 286: ......
Страница 287: ...MAN Diesel Turbo B 19 Safety and control system Page 1 1 B 19 Safety and control system 2018 04 13 en...
Страница 293: ...ENGINE AUTOMATION MAN Diesel Turbo SE SaCoSone GENSET System description Revision 1 5...
Страница 306: ...MAN Diesel Turbo SaCoSone GENSET SaCoSone GENSET Communication from GenSet Revision 1 7...
Страница 309: ...MAN Diesel Turbo Table of Contents...
Страница 324: ......
Страница 326: ......
Страница 327: ...MAN Diesel Turbo B 20 Foundation Page 1 1 B 20 Foundation 2018 04 13 en...
Страница 328: ......
Страница 334: ......
Страница 335: ...MAN Diesel Turbo B 21 Test running Page 1 1 B 21 Test running 2018 04 13 en...
Страница 336: ......
Страница 341: ...MAN Diesel Turbo E 23 Spare parts Page 1 1 E 23 Spare parts 2018 04 13 en...
Страница 342: ......
Страница 348: ......
Страница 350: ......
Страница 351: ...MAN Diesel Turbo P 24 Tools Page 1 1 P 24 Tools 2018 04 13 en...
Страница 379: ...MAN Diesel Turbo B 50 Alternator Page 1 1 B 50 Alternator 2018 04 13 en...
Страница 380: ......
Страница 386: ......
Страница 389: ...MAN Diesel Turbo B 98 Preservation and packing Page 1 1 B 98 Preservation and packing 2018 04 13 en...
Страница 390: ......
Страница 392: ......