Connecting Electrical System
5.9.1
Connecting Starter (BOSCH)
The threads of the cable connection (2) of the
starter (1) are specified in the installation drawing.
Battery capacity, cable length and cable cross-
section should be selected to match.
The required starter cable cross-section, which
depends on the recommended starter cable
lengths, are listed in the following table.
Engine models
E0834 LE302 / E0836 LE202
Starter type
Bosch
Rated voltage
V
24
Rated output
kW
4
Permitted battery capacity
1)
Ah
66
88
110
Starter short circuit current
A
at 20
_
C with a feed cable of 1m
W
/m
940
1050
1100
Required starter cable cross-section
(copper)
mm
2
Recommended starter cable lengths in meters
(valid for the cables to and from, voltage loss: max. 4% based on
0.5 x starter short circuit current)
50
70
95
120
140 (2 x 70)
5.7
7.9
10.8
13.6
15.9
5.0
7.1
9.6
12.2
14.2
4.8
6.8
9.2
11.6
13.6
Control cable between starter switch
and starter terminal 50
mm
2
Max. permitted line length in meters
2.5
4.0
6.0
9.8
15.7
23.6
1) Batteries according to DIN 72 311. The largest capacity listed for each starter must not be exceed to
prevent damage to the starter and starter ring gear.