PROGRAMMING 

Enter the Cooling Program

1)  Press the SYSTEM button until the Cool icon appears .

2) Follow 

Enter Heating Program

 instructions for entering

  cooling times and temperatures .

Automatic Schedule

This feature provides a method to program every day with the 

most popular time and temperature settings using one key . 

For this feature to be available, the Auto Schedule options 

(Installer/Configuration menu item 17, 

AS Heat

, or item 18, 

AS Cool

) must be selected 

On

 .

To use Auto Schedule, press 

Run Schedule

 to be sure you 

are in normal operating mode . In SYSTEM Heat mode, use 

the 

 

or   keys to select your “Comfort Temperature” .  

When your “Comfort Temperature” is selected, press 

Auto

 

Schedule

 key. The key will begin to flash indicating that the 

feature is ready to store your selected temperature . Press 

Auto Schedule

 a second time to complete the process . The 

Auto Schedule

 key will disappear to indicate that the Auto 

Schedule command has been accepted .
In Heat mode the thermostat will maintain your “Comfort Tem-

perature” during the Morning, Day and Evening periods and 

setback 6° for the Night . Morning period will begin at 6:30 AM 

and Night period will begin at 10:30 PM . 
To set the Auto Schedule temperature for Cool mode, press 

SYSTEM to change the mode to Cool and repeat setting the 

temperature .  In Cool mode, the thermostat will maintain your 

selected “Comfort Temperature” continuously . 
The “Comfort Temperature” can be temporarily overridden by 

changing the setpoint temperature using the 

 

or   keys . 

Once Auto Schedule has been set and the key has disap-

peared, it can be reset in the Installer/ Configuration menu.

Entering Fan Program

In the Set Schedule mode, the 

FAN

 key is used to select the 

fan operation during a program period . The default state of 

the 

Fan

 key is 

FAN Auto

 (fan runs during a call for cool but 

not on a call for heat) . It can be changed to 

FAN Prog

 (fan 

runs during a program period) . Each press of the FAN key will 

change the mode of the fan between 

Auto

 and 

Prog

 . 

In the Run mode, when a program period that has 

FAN Prog

 

begins, the fan will turn on and stay on during the com-

plete period . The display will show 

FAN On Prog

 . Pressing 

the 

FAN

 key will change 

FAN On Prog 

to

 On 

(fan running 

continuously) or 

Auto

 . To return to

 FAN On Prog

, press 

Run 

Schedule

 .

Programming Tip: Copy Program

When programming your thermostat, you may copy the pro-

gram from one day to another day or group of days using the 

Copy

 key . In 7 day programming mode, a day can be copied 

to another day or all six other days . In 5/1/1 day programming 

mode the weekday (Mon – Fri) program can be copied into 

Sat and Sun or either Sat or Sun .

To copy a program from one day to another:

1)  In Set Schedule mode, enter the program for the day or 

select the day you wish to copy by pressing 

Advance 

Day

 .

2) Press 

Copy

 . The display will show 

“Copy”

 next to the 

SYSTEM key and the day of the week that will be copied .

3) Press 

Advance Day

 . The day being copied will be indi-

cated and the other days will be flashing. 

4)  If you wish to copy to all days skip to next step or press 

Advance Day

 until the day you wish to copy to is flashing.

5) Press 

Copy

 . 

“Copy”

 will disappear, the day you copied 

from will disappear and the day(s) you copied to will be 

on .

6)  If you wish to copy this same program into other days, 

press 

Copy

 and repeat steps 3, 4 and 5 .

7) Press 

Run Schedule

 to return to normal operation .

Fill in the blank schedule on the next page then:

Enter the Heating Program

1)  Press the Menu button and then press Set Schedule . 

  Press SYSTEM button to select either 

"Heat"

 or 

"Cool"

 in 

  the system switch area indicating the active mode being 

  programmed . You can switch to the other mode by 

  pressing the system switch at any time .

2)  The top of the display will show the day(s) being pro-

grammed . The time and set at temperature are also

 displayed . 

"Morning"

 will also be displayed to indicate

  the period .

3) Press   or   key to change the temperature to your

  selected temperature for the 1st heating period (Morning) .

4) Press   or   key to adjust the start time for period .

  The time will change in 15 minute increments .

5) Press 

FAN

 to select 

Auto

 or 

Prog

 .

6)  After you have set the time and the temperature for the  

period to begin, press Set Schedule to advance to the  

next program period .

7)  Repeat steps 2 through 6 until all of the program times

  and temperatures are set for all program periods on 

  that day . 

8)  Press "Advance Day" to change to the next day and

  repeat steps 2 through 8 .

9)  When programming is complete and all of the times and

  temperatures match your desired heating schedule, press 

  Run Schedule . The thermostat will now run your program .

Содержание 1F95-1277

Страница 1: ...d in household trash Do not touch any spilled mercury Wearing non absorbent gloves clean up any spilled mercury and place in a sealed container For proper disposal of a product containing mercury or a sealed container of spilled mercury place it in a suitable shipping container Refer to www thermostat recycle org for location to send the product containing mercury Save these instructions for futur...

Страница 2: ...ing existing mounting holes and the holes drilled are too large and do not allow you to tighten base snugly use plastic screw anchors to secure the base 4 Fasten base snugly to wall using mounting holes shown in Figure 1 and two mounting screws Leveling is for appearance only and will not affect thermostat operation 5 Connect wires to terminal block on base using appropriate wiring schematic see d...

Страница 3: ...rature Limit and Keypad Lockout when limited range is activated and locked Displays only Temperature Limit when limited range is activated 2 Indicates period of day being programmed 3 RUN SCHEDULE run program button 4 SET TIME button or HOLD temperature button 5 Displays Change Filter when the system has run for the programmed filter time period as a reminder to change or clean your filter 6 COPY ...

Страница 4: ...Anticipation cycle rate auxiliary This item is only to appear if HP 1 or HP 2 is selected above 10 10 8 CL OFF On Selects Compressor Lockout 11 11 9 dL On OFF Selects Continuous Display backlight intensity 12 12 10 dL LO HI Selects Backlight Intensity 13 13 11 0 4 LO to 4 HI Selects Adjustable Ambient Temperature Display range 4 LO to 4 HI 14 14 12 F C Selects F C Display temperature units in Fahr...

Страница 5: ...nuously running during the periods of high demand Periods of high demand will nor mally occur during the late afternoon and early evening on the hottest days of the summer As demand lessens the adjustments to setpoint temperature are reversed until setpoint temperature returns to normal and Cool Savings no longer flashes 1 This control can be configured for MS2 Multi Stage System 2 heat 2 cool HP1...

Страница 6: ...etting Heat Off Cool or Auto INSTALLER CONFIGURATION MENU 23 24 Select Fast Second Stage ON or OFF In the run mode with the fast Heat feature enabled FA Heat On if the Heat setpoint temperature is manually raised by 3 F 2 C or more above the actual temperature using the second stage will energize immediately With FA OFF second stage will not energize until the setpoint tempera ture is 1 F or more ...

Страница 7: ...rogram Override period can range from 15 minutes to 7 days Example If you turn up the heat during the morning program it will be automatically lowered later when the temporary hold period ends To cancel the temporary setting at any time and return to the program press Run Schedule If the SYSTEM button is pressed to select AUTO the thermostat will change to Heat or Cool whichever ran last If it swi...

Страница 8: ...an running continuously or Auto To return to FAN On Prog press Run Schedule Programming Tip Copy Program When programming your thermostat you may copy the pro gram from one day to another day or group of days using the Copy key In 7 day programming mode a day can be copied to another day or all six other days In 5 1 1 day programming mode the weekday Mon Fri program can be copied into Sat and Sun ...

Страница 9: ...s with the times and temperatures you want Keep the following guidelines in mind when planning your program In Heating lower temperatures will save energy In Cooling higher temperatures will save energy If you plan on using Auto Changeover do not program the heating higher than the cooling Worksheet for Re Programming 5 1 1 and 7 Day Program Cooling Program Wake Up Leave For Work Return Home Go To...

Страница 10: ...the local sensor is fixed In normal operation of the thermostat the current tempera ture displayed will be the weighted average of the local sensor and the remote sensor using the formula local sensor weight x local sensor temperature remote sensor weight x remote sensor temperature local sensor weight remote sensor weight Example Local sensor temperature is 80 and the remote sensor is 70 If weigh...

Страница 11: ...on or place of purchase for a replacement If the thermostat clicks contact the furnace manufacturer or a HVAC service person to verify the heating is operating correctly No Cool 1 Cooling system requires service or thermostat requires replacement Same as diagnostic for No Heat condition except set the thermostat to COOL and lower the setpoint below the room temperature There may be up to a five mi...

Страница 12: ...h Temtrol Venmar CES and Ventrol CES Group LLC is a subsidiary of Nortek Inc a glob al diversified company whose many market leading brands deliver broad capabilities and a wide array of innovative technology driven products and solutions for lifestyle improvements at home and at work www mammoth inc com CESGroup has a policy of continuous product improvement and reserves the right to change desig...

Отзывы: