background image

Big Blue Universal Thermostat with 

Automatic Heat/Cool Changeover Option

Single Stage, Multi-Stage, Heat Pump

Installation and Operating Instructions for Model:

APPLICATIONS 

1F95-1277 Touchscreen Thermostat

SPECIFICATIONS 

Electrical Rating:

 

Battery Power. . . . . . . . . . . . . . . . . . . . . . . . . .   mV to 30 VAC, NEC Class II, 50/60 Hz or DC

 

Input-Hardwire . . . . . . . . . . . . . . . . . . . . . . . . .   20 to 30 VAC

Terminal Load  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   1.5A per terminal, 2.5A maximum all terminals combined

Setpoint Range . . . . . . . . . . . . . . . . . . . . . . . . . . . .   45 to 99°F (7 to 37°C)

Differential (Single Stage) . . . . . . . . . . . . . . . . . . . .   Heat 0.6°F; Cool 1.2°F

Differential (Multi-Stage) . . . . . . . . . . . . . . . . . . . . .   Heat 0.6°F; Cool 1.2°F

Differential (Heat Pump)  . . . . . . . . . . . . . . . . . . . . .   Heat 1.2°F; Cool 1.5°F

Operating Ambient. . . . . . . . . . . . . . . . . . . . . . . . . .   32°F to +105°F (0 to +41°C)

Operating Humidity . . . . . . . . . . . . . . . . . . . . . . . . .   90% non-condensing max.

Shipping Temperature Range . . . . . . . . . . . . . . . . .   -4 to +150°F (-20 to +65°C)

Dimensions Thermostat. . . . . . . . . . . . . . . . . . . . . .   4-9/16"H x 5-13/16"W x 1-3/16"D

CA UTION

!

To prevent electrical shock and/or equipment damage, 

disconnect electric power to system at main fuse or 

circuit breaker box until installation is complete.

ATTENTION: MERCURY NOTICE

This  product  does  not  contain  mercury.  However,  this 

product may replace a product that contains mercury.
Mercury  and  products  containing  mercury  must  not  be 

discarded  in  household  trash.  Do  not  touch  any  spilled 

mercury.  Wearing  non-absorbent  gloves,  clean  up  any 

spilled mercury and place in a sealed container. For proper 

disposal  of  a  product  containing  mercury  or  a  sealed 

container of spilled mercury, place it in a suitable shipping 

container.  Refer  to 

www.thermostat-recycle.org

  for 

location to send the product containing mercury. 

Save these instructions for future use!

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS 

CAREFULLY BEFORE INSTALLING OR OPERATING THIS 

CONTROL COULD CAUSE PERSONAL INJURY AND/OR 

PROPERTY DAMAGE.

Model

 

Programming Choices

1F95-1277

Non-Programmable 5/1/1 Day

7 Day

THERMOSTAT APPLICATION GUIDE

Description

Heat Pump (No Aux. or Emergency Heat)

Yes

Heat Pump (with Aux. or Emergency Heat)

Yes

Systems with up to 3 Stages Heat, 2 Stages Cool

Yes

Heat Only Systems

Yes

Millivolt Heat Only Systems – Floor or Wall Furnaces

Yes

Cool Only Systems

Yes

Gas or Oil Heat

Yes

Electric Furnace

Yes

Hydronic (Hot Water) Zone Heat – 2 Wires

Yes

Hydronic (Hot Water) Zone Heat – 3 Wires

Yes

Wired Remote Temperature Sensor (Indoor/Outdoor)

Yes

Dual Fuel Feature (Heat Pump Mode)

Yes

Index

Page

Installation

2

Wiring Connections

2

Thermostat Quick Reference

3
4

Operating Your Thermostat

7

Programming

7

Troubleshooting

11

PART NO. 37-6753D

Replaces 37-6753C

1150

www.mammoth-inc.com

Содержание 1F95-1277

Страница 1: ...d in household trash Do not touch any spilled mercury Wearing non absorbent gloves clean up any spilled mercury and place in a sealed container For proper disposal of a product containing mercury or a sealed container of spilled mercury place it in a suitable shipping container Refer to www thermostat recycle org for location to send the product containing mercury Save these instructions for futur...

Страница 2: ...ing existing mounting holes and the holes drilled are too large and do not allow you to tighten base snugly use plastic screw anchors to secure the base 4 Fasten base snugly to wall using mounting holes shown in Figure 1 and two mounting screws Leveling is for appearance only and will not affect thermostat operation 5 Connect wires to terminal block on base using appropriate wiring schematic see d...

Страница 3: ...rature Limit and Keypad Lockout when limited range is activated and locked Displays only Temperature Limit when limited range is activated 2 Indicates period of day being programmed 3 RUN SCHEDULE run program button 4 SET TIME button or HOLD temperature button 5 Displays Change Filter when the system has run for the programmed filter time period as a reminder to change or clean your filter 6 COPY ...

Страница 4: ...Anticipation cycle rate auxiliary This item is only to appear if HP 1 or HP 2 is selected above 10 10 8 CL OFF On Selects Compressor Lockout 11 11 9 dL On OFF Selects Continuous Display backlight intensity 12 12 10 dL LO HI Selects Backlight Intensity 13 13 11 0 4 LO to 4 HI Selects Adjustable Ambient Temperature Display range 4 LO to 4 HI 14 14 12 F C Selects F C Display temperature units in Fahr...

Страница 5: ...nuously running during the periods of high demand Periods of high demand will nor mally occur during the late afternoon and early evening on the hottest days of the summer As demand lessens the adjustments to setpoint temperature are reversed until setpoint temperature returns to normal and Cool Savings no longer flashes 1 This control can be configured for MS2 Multi Stage System 2 heat 2 cool HP1...

Страница 6: ...etting Heat Off Cool or Auto INSTALLER CONFIGURATION MENU 23 24 Select Fast Second Stage ON or OFF In the run mode with the fast Heat feature enabled FA Heat On if the Heat setpoint temperature is manually raised by 3 F 2 C or more above the actual temperature using the second stage will energize immediately With FA OFF second stage will not energize until the setpoint tempera ture is 1 F or more ...

Страница 7: ...rogram Override period can range from 15 minutes to 7 days Example If you turn up the heat during the morning program it will be automatically lowered later when the temporary hold period ends To cancel the temporary setting at any time and return to the program press Run Schedule If the SYSTEM button is pressed to select AUTO the thermostat will change to Heat or Cool whichever ran last If it swi...

Страница 8: ...an running continuously or Auto To return to FAN On Prog press Run Schedule Programming Tip Copy Program When programming your thermostat you may copy the pro gram from one day to another day or group of days using the Copy key In 7 day programming mode a day can be copied to another day or all six other days In 5 1 1 day programming mode the weekday Mon Fri program can be copied into Sat and Sun ...

Страница 9: ...s with the times and temperatures you want Keep the following guidelines in mind when planning your program In Heating lower temperatures will save energy In Cooling higher temperatures will save energy If you plan on using Auto Changeover do not program the heating higher than the cooling Worksheet for Re Programming 5 1 1 and 7 Day Program Cooling Program Wake Up Leave For Work Return Home Go To...

Страница 10: ...the local sensor is fixed In normal operation of the thermostat the current tempera ture displayed will be the weighted average of the local sensor and the remote sensor using the formula local sensor weight x local sensor temperature remote sensor weight x remote sensor temperature local sensor weight remote sensor weight Example Local sensor temperature is 80 and the remote sensor is 70 If weigh...

Страница 11: ...on or place of purchase for a replacement If the thermostat clicks contact the furnace manufacturer or a HVAC service person to verify the heating is operating correctly No Cool 1 Cooling system requires service or thermostat requires replacement Same as diagnostic for No Heat condition except set the thermostat to COOL and lower the setpoint below the room temperature There may be up to a five mi...

Страница 12: ...h Temtrol Venmar CES and Ventrol CES Group LLC is a subsidiary of Nortek Inc a glob al diversified company whose many market leading brands deliver broad capabilities and a wide array of innovative technology driven products and solutions for lifestyle improvements at home and at work www mammoth inc com CESGroup has a policy of continuous product improvement and reserves the right to change desig...

Отзывы: