Programming Options

- 6 -

0

#

0

2

0

1

0

Auxiliary options

“Sound Options” will be displayed. If the user wishes, the user could adjust any one of the following by 
entering the corresponding keys: 

0

#

0

3

0

1

0

Setting System Time & Date

” will be displayed. Indicating that the current time must 

be entered. 

The user must enter the time in a 24 hour format

 

with hour first followed by the minute. 

Set Time

If the user enters an invalid time, “ERROR” will be displayed 
and no changes will be made.

Once the user enters the Date the unit then saves the date and the 
operation is complete. 

M

M

H H

M

Y

D D

Y

M

After setting the time the user will be required to set the date. 

Enter Date

” will be displayed. Indicating that the current Date 

must be entered. 

The user must enter the Date in the following 

format DD/MM/YY.

 

If the user enters an invalid Date, “ERROR” will be displayed 
and no changes will be made.

Buzzer option

0

#

0

2

0

1

0

1

“Buzzer” will be displayed. The user may then enter 1 or 0 to 
toggle the buzzer on or off respectively. 

1

0

BUZZER ON

BUZZER OFF

Save Changes

#

Once the user is done the user will press the hash “#” key to 
save the settings.

Schedule Bypass

0

#

0

2

0

1

0

2

“Schedule Bypass” will be displayed. The user may then enter 
1 or 0 to toggle the Schedules on or off respectively. Schedules 
will be bypassed for only one day.

1

0

Schedule Bypass ON

Schedule Bypass OFF

Save Changes

#

Once the user is done the user will press the hash “#” key to 
save the settings.

NOTE: Schedule bypass option only bypasses the Schedule 
for 1 day, to disable the schedule follow instructions under 
setting schedules.

0

#

0

5

0

1

0

Transmitter Code

Enter the Transmitter code in decimal format. This code will be 
transmitted on trigger. To send a test code press the 4 and 6 button

Once the user enters the code the user then enters the hash key 
saving the code. 

Save Changes

#

3

4

1 2

NOTE:  THE HOME GUARD WILL ONLY 
TRANSMIT MAMI SMART 16BIT ON 403.55 

!

Содержание HomeGuard 32

Страница 1: ...X00383 November 2012 Portable_HomeGuard_32_instr_v01 cdr Portable Monitor for wireless outdoor and indoor sensors MAMI Prelim inary issue MAMI MANUFACTURING AND MINOR INVENTIONS HomeGuard 32...

Страница 2: ...OPTIONS INTERNAL BUZZER SCHEDULE BYPASS SETTING THE SYSTEM TIME DATE SETTING THE TRANSMITTER CODE NAMING OF ZONES SETTING LEVELS CHANGING USER CODE SELF LEARNING DETECTORS SELF LEARNING REMOTE S NAMIN...

Страница 3: ...3 entries Optional External Antenna On Board wireless receiver and Transmitter Receiver frequency at 433MHz Transmitter at 403MHz 6 External triggers through transmitter Supports MAMI Silentron and O...

Страница 4: ...ARMED DISARMED Suppose the unit is armed and power is switched off and on the unit will remain armed after it switches back ON Warn Chime mode The HomeGuard32 is capable of going into a Warn Chime mo...

Страница 5: ...isarm Arms to Level A only Pg 5 Setting Transmitter code Pg 6 0 0 5 0 1 0 0 1 1 0 1 0 Change User Code Pg 7 0 2 2 0 1 0 Clear All Remote Controls Pg 10 0 2 1 0 1 0 Deleting Devices Pg 9 Warning Mode L...

Страница 6: ...d a tamper signal the user must turn bit 8 of the dip switch off a tamper signal will then be sent to resend press the tamper button If the user wishes to leave the tamper active the user must leave b...

Страница 7: ...nters the time the user then enters the hash key saving the time corresponding to the time the unit will automatically arm SCHEDULE 1 DISARM time will be displayed Indicating that the time for schedul...

Страница 8: ...nd no changes will be made Buzzer option 0 0 2 0 1 0 1 Buzzer will be displayed The user may then enter 1 or 0 to toggle the buzzer on or off respectively 1 0 BUZZER ON BUZZER OFF Save Changes Once th...

Страница 9: ...o exit Continue with zone Z keyed in Naming Renaming of Zones Z 2 ABC Exit Z 0 0 A 0 1 0 Setting Level The user must key in the user code followed by 0 then the level A B C or D the user must select a...

Страница 10: ...star to continue and hash to save and Exit Remote Added Trigger Remote Trigger Device EXIT Continue EXIT Continue The user is then prompted to either replace an existing device or add as new Replace E...

Страница 11: ...roll Next A Scroll Previous D Save Changes B Back space 2 ABC 0 Space or 0 If the user entered the C key the user has to trigger the device to rename if the code is not in the system error will be dis...

Страница 12: ...RN or Chime mode In this mode the unit will not trigger an alarm but sound a chime when any detector in the level has been triggered To set warn Level A D The User simply Holds down desired Key A D an...

Страница 13: ...ll alarm and arming or disarming the unit are logged on to the units EEPROM a maximum of 80 different alarms can be logged Each log displays the time date type of alarm and Zone information in the cas...

Страница 14: ...e name or the zone number together with the device either the device name or the device number BattLow LOUNGE WINDOW BATTERY LOW ON SENSORS ALERT BattLow Zone 5 Device 1 In the case that any of the se...

Страница 15: ...e the battery EXTERNAL BUZZER When the unit is wall mounted with a power source plugged in 12V dc is available at the buzzer Output EXTERNAL LED The external Led Output will supply 12volts DC to the L...

Страница 16: ...YSTEM 1000 2 9 RESET ENTIRE UNIT TO DEFAULT 1000 3 3 VIEW DEVICE LOG PANIC PANIC ACTIVATION NOTES A A Means Press and hold the A key until it beeps A A Means Press and hold the and the A keys until it...