![MALTEC GAS-2500Mt Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/maltec/gas-2500mt/gas-2500mt_instruction-manual_3934068015.webp)
Safety Clearance
1. GENERAL INSTRUCTIONS
1.1 The heaters mentioned in this manual must only be used outdoors or in well ventilated
surroundings.
1.2 For every KW it is necessary to have permanent ventilation of 25cm³, equally
distributed between the floor and high level, with a minimum outlet of 250cm³.
1.3 Gas cylinders must be used and kept in accordance with current regulations.
1.4 Never direct the hot air flow towards the cylinder.
1.5 Use only the supplied pressure regulator.
1.6 Never use the heater without its cover.
1.7 Do not exceed 100W/m³ of free room. The minimum volume of the room must be larger
than 100m³.
1.8 Do not obstruct the inlet or outlet sections of the heater.
1.9 If the heater has to work for a long period at its maximum capacity, it’s possible that ice
will form on the cylinder. This is due to excessive vapor withdrawal. Not for this reason,
or for any other, should the cylinder be heated. To avoid this effect, or at least to reduce
it, use a large cylinder or two cylinders linked together (figure1).
1.10 Do not use the heater in cellars, basements or in any room below the ground level.
1.11 In case of malfunction, please contact the technical assistance service.
1.12 After use, turn the gas cylinder tap off.
1.13 The gas bottle must always be replaced following safety rules away from any
possible source of ignition.
1.14 The gas hose must not be twisted or bent.
1.15 The heater must be placed where there is no risk of fire, the hot air outlet must be at
least 3m from any flammable wall or ceiling and must never be directed towards the
gas bottle.
1.16 Only use original gas hose and spare parts.
15/20