29
Time setting
LED mode setting
Standby, Load and
LED status
Impulse, Load and
LED status
Whether Impulse is
controlled by Lux
No test mode
Load OFF.
LED flashes
in turn.
Load ON.
W
LEDs all OFF.
Yes
Walk test
The purpose of the walk test is to select a proper installation place and gain the desired detection
coverage. Turn Meter knob to “ + “, Time knob to “ Test “, then conducting a walk test referring to
step “Knob setting” (See Fig.18).
Fig. 18
Fig. 18-A
Fig. 18-B
Fig. 18-C
NOTE
It takes approx. 60 sec to warm up after power is supplied, then enters into normal
operation mode.
Start
Start
Start
Finish
Finish
Finish
•
Test procedure
1. Switch power on.
2. User must be within the detection coverage.
3. After the warming up period, walk from outside across to the detection pattern until LED turns
on for approx. 2 sec .
4. Rotating sensor head to change the detection direction (See Fig. 13-A, Fig. 13-B & Fig. 15-A,
Fig. 15-B).
5. Adjust Meter knob to change detection range.
6. Adjust Time knob to change the delay time for light.
7. Refer to section “Usage of lens shield“
to use the lens mask for minimize the detection zone.
8. Repeat step 5 - 6 until meets user’s demands.
9. Be aware of the walk direction (See Fig. 4).