7. Wiring Diagram

9. Trouble Shooting

Y

D

E

M

E

R

E

S

U

A

C

Y

D

E

M

E

R

 

E

S

U

A

C

 

N

O

I

T

C

N

U

F

L

A

M

The fixture does not light up

The fixture is always on

Check detection area setting

The fixture is on when it should not

Incorrect daylight threshold setting

Continued movement in the detection zone 
Sudden change in temperature due to weather (wind, rain, snow) or air 
expelled from fans, open windows

Detection zone not targeted

Faulty fixture

No power supply

Adjust daylight threshold setting
Replace fixture

Check power to sensor

Check detection area setting

Adjust zone, change installation site

Description of the 
Button Functions 
(remote control 99 190 27)

8. 

99 190 27

6

8

10

11

12

13

14

2

4

1

3

7

9

5

Permanent ON/OFF [               ]

Press button      to select permanent ON or permanent OFF mode.
 * Press button     /     to resume automatic operation. 

Semi-auto Mode [ button     &     ]

Power output [ button 

   

 ]

Press button     , the light output shifts between 80% and 100%.
Note: the function of “Sensor off” and “Twilight” are disabled.          

Ambient daylight threshold [ button 

    

 ]

Detection range [ zone     ] 

Press buttons in zone 

   

  to set HF detection range at 100% / 75% / 

50% / 10%.

Stand-by time [ zone     ]

Press buttons in zone     to set the stand-by time at 0s / 10s / 1min / 
5min / 10min / 30min / 1h / +∞. 
Note: “0s” means on/off control; “+∞” means bi-level control, 100% 
          on when motion detected, and remains at the stand-by 
          dimming level when no presence after hold-time.

Daylight threshold [ zone 

   

  ]          

Press buttons in zone     to set the daylight sensor at 50Lux / 100Lux 
/ 300Lux / 500Lux or Disable as threshold / target Lux level.
Note: 2Lux / 10Lux are disabled.
         To set daylight sensor at 100Lux / 300 Lux / 500Lux, press 
         button     Shift at first.

button 

Auto Mode [ button     ]

Brig/- [ button     ]

Press button     to adjust light brightness to reset the target lux level. 

Scene prog. [ zone      ] (One-key-commissioning)

1. Press button     Shift, the red LED flashes for indication. 
2. Press button 

    

, the ambient lux level is sampled and set as  

    daylight threshold / target Lux level.

Hold time [ zone     ]

Press buttons in zone     to set the hold time at 2s / 30s / 1min / 
5min / 10min / 15min / 20min / 30min.
Note: 1.To set hold-time at 30s / 5min / 15min / 30min, press button 
                Shift at first.
         2. 2s is for test purpose only, stand-by time and daylight     
             sensor settings are disabled in this mode.
* To exit from Test mode, press button     or any button in zone     .    

Stand-by dimming level [ zone      ]

Press buttons in zone     to set the stand-by dimming level at 10% / 
20% / 30% / 50%.

 Dual tech & RF mode [ zone     ]

 1. Press buttons in zone     to select sensor technology.
     HF+PIR: Light is on when both HF and PIR sensors are activated.
     HF/PIR: Light is on when HF or PIR sensors are activated.
 2. Learn / Erase, Transmit, RX100% and RX STBY% are disabled.

Shift [ button 

    

 ]

RESET [ button     ]

Press button     , all settings go back to the rotary switch settings.
Sensor mode return to DIP switch settings.

Press button     to initiate automatic mode. The sensor starts working
and all settings remain as before the light was switched ON/OFF.

1. Press button “Start” to program.
2. Select the buttons in      “Detection range”,     /     “Daylight threshold”, 
        “Hold time”,      “Stand-by time”,      “Stand-by dimming level” to   
    set all parameters.
3. Press button “Memory” to save all the settings programmed in the 
    remote control.
4. Press button “Apply” to set the settings to each sensor unit(s).     
    For example, to pre-set detection range 100%, daylight threshold
    Disable, hold time 5min, stand-by time +∞, stand-by dimming level 
    30%, steps should be:
    Press button     Start, button     100%,     Disable,     Shift,     5min,        
         Shift,     +∞ ,     30%,     Memory. By pointing to the sensor unit(s)   
    and pressing      Apply, all settings are passed on the sensor(s).

Press button     , the LED on the top left corner flashes for indication.    
All values / settings in RED are in valid for 20 seconds. 

1. Press button     Shift (the red LED flashes for indication), 
2. press button     to initiate semi-auto mode. The fixture is manually on 
    by push-switch and automatically off in semi-auto mode.

1

8

3

3

2

9

10

11

12

13

14

14

13

12

11

11

10

9

8

2

2

3

3

3

3

4

4

4

5

6

7

7

7

7

3

3

8

8

9 10

10

11

13

12

11

12

13

6

5

4

1

2

4

3

Detection Pattern

7. 

HF walking towards 10m

PIR walking across 8m

6. Wiring Diagram

SYNC P N L

DA+  DA-

DA-  DA+

- + L N

LED

99 190 23

SYNC P N L

L
N

DA+  DA-

99 190 23

LED driver

DA-  DA+

- + L N

LED

LED driver

DA-  DA+

- + L N

LED

LED driver

Max. 20pcs

Max. 20pcs

DA-  DA+

- + L N

LED

LED driver

Malmbergs Elektriska AB  |  PO Box 144, SE-692 23 Kumla, SWEDEN  |  Phone: +46 19 58 77 00  |  Fax: +46 19 57 11 77  |  [email protected]  |  www.malmbergs.com