Mäktig 710135 Скачать руководство пользователя страница 13

13

 

 

 

Front panel view 

1. Display 

Panel

 – Shows present voltage, present current, present 

battery capacity or wrong condition code. 

With AC power input, when unit is not connected to the battery, the 
charger shows that there is no power output with the display panel 
present moving “8”. After connected to the battery, the panel will 
display the battery information according to what you choose. If the 
battery voltage is higher than 13.6±0.2V, the panel will display “FUL”.  
When an error occurs, the panel will show a code.  Error codes and 
solutions are listed in the troubleshooting table.  

2.  Current Indicator

 – Green LED indicator. When the display panel 

indicates the present current, this LED indicator turns on. 

3.  Voltage Indicator

 – Green LED indicator. When the display panel 

indicates the present voltage, the voltage LED indicator turns on.  

4.  Battery level indicator

 – When the display panel indicates the battery 

level, this LED indicator will illuminate. 

 

5.  Automatic charging indicator

 – Indicates the charging rate you 

choose is automatic. 

Code Condition 

LO low 

Battery 

60~90 

Current battery level 

FUL Full 

Battery 

Содержание 710135

Страница 1: ...refully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating Failure to follow the safety rules and other basic safety precautions may damage the equipment or create hazardous condi...

Страница 2: ...16 10 TROUBLESHOOTING FAULT CODES 17 11 MAINTENANCE AND CARE 18 CONVENTIONS USED The following conventions are used in this manual WARNING Warnings identify conditions that could result in personal in...

Страница 3: ...ct connection and reverse connection Includes ring terminal and clamp wiring This manual will explain how to use the charger safely and effectively Please read and follow these instructions and precau...

Страница 4: ...ects associated with the use of this product may expose you to lead Wash hands after handling Read all instructions and cautions printed on the battery charger battery and vehicle or equipment using b...

Страница 5: ...ad acid batteries Avoid touching your eyes while working with a battery Have plenty of fresh water and soap nearby for use in case battery acid contacts your eyes skin or clothing If this happens wash...

Страница 6: ...these guidelines Make sure that the pins on the charger s power cord fit firmly into the extension cord and that the extension cord fits firmly into the receptacle Check that the extension cord is pr...

Страница 7: ...d Clean the battery terminals Be careful to keep corrosion or battery acid from getting in or around your eyes For batteries with removable vent caps if required add distilled water to each cell until...

Страница 8: ...ry charger to a positive POS P ungrounded post of battery Connect the negative black clip to vehicle chassis or engine block away from battery Do not connect clip to carburetor fuel lines or sheet met...

Страница 9: ...ossible and then connect the negative black charger clip to the free end of cable 5 Do not face battery when making final connection 6 Connect charger AC supply cord to electric outlet 7 Charge batter...

Страница 10: ...cted charging voltage V will be displayed The voltage displayed is the charging voltage and usually will be higher than the battery s resting voltage Battery Capacity When selected approximate percent...

Страница 11: ...ON METHODS This charger comes with 2 run connect charging leads for extra versatility standard clamps and ring terminals The battery may be charged using any of the two connection options Warning you...

Страница 12: ...y activate Battery Reconditioning mode indicated by a blinking yellow LED The digital display will show in turns If desulphation is successful normal recharging will resume If the first attempt at des...

Страница 13: ...isplay FUL When an error occurs the panel will show a code Error codes and solutions are listed in the troubleshooting table 2 Current Indicator Green LED indicator When the display panel indicates th...

Страница 14: ...and the voltage is lower than 13V The process cycles every 4 0 5h until the voltage is higher than 13V If it cycles 5 times and the voltage is still lower than 13V there will be a code F01 present on...

Страница 15: ...Start mode 1 Make battery and AC connections as outlined in CHARGING A BATTERY INSTALLED IN A VEHICLE 2 Press the Engine Start button Once the Engine Start button is pressed the charger will begin to...

Страница 16: ...tery Rating A higher rated battery will take longer to charge than a lower rated battery under the same conditions A battery is rated in ampere hours Ah reserve capacity RC and cold cranking amps CCA...

Страница 17: ...3 Charge current is too high A load may be connected to the battery Disconnect the load and attempt to charge again F04 Temperature of the charger is too high High ambient temperature Ensure adequate...

Страница 18: ...d or debris that might have come in contact with the clamps to prevent corrosion Store the power and output cable neatly to prevent damage Occasional cleaning of the battery charger case with a soft c...