TROUBLESHOOTING
PROBLEM
CAUSE
SOLUTION
Pump does not dispense fluid or does not
prime.
1.
Pump is drawing in air, instead of fluid.
1.
Tighten suction tube with the pump inlet and
check the seals for leaks. Tighten fasteners and
replace seals, if needed.
2.
Suction tube inlet is clogged
2.
Clean suction tube inlet
Handle difficult or impossible to move.
1.
Pump has not been used for a long time
1.
Inspect for deposits on components. Clean or
replace parts. Flush pump with the media being
used if pump has not been in use for a long
period of time.