.6 DOMESTIC HOT WATER NTC SENSOR

When a sensor failure occurs in hot water system, H2 warning code appears on LCD screen.

7

.7 CENTRAL HEATING NTC SENSOR

When a sensor failure occurs in central heating system.H1 warning code appears on the LCD 

screen

7

.8 HIGH WATER PRESSURE PROTECTION

When there is over pressure in the heating system, the 3 bar safety valve discharges water 

and decreases the pressure.

7

.9 PRECAUTION AGAINST PUMP LOCK

When the boiler is in the OFF position, the pump is operated in every 24 hours by the control 

card for a certain period of time to prevent locking and jamming of the pump.

7

.10 MOTORISED VALVE SAFETY

When the boiler is in the OFF position, the 3-way valve is operated in every 24 hours by the 

control card for a certain period of time. The motorized valve returns to its previous position 

after a certain period of time after changing the position.

7

.11 AUTOMATIC BY-PASS

If there is thermostatic valve one each radiator, even when all thermostatic valves are switched 

off, there is an automatic by-pass system in order to provide of passing of minimum water flow 

in order to prevent rapid over heating of the boiler.

8.

MAINTENANCE

We recommend that the following controls are made by authorised service once a year.

1-Check for leaks in the water circuit and, if necessary, replace the joints to ensure water

tightness.

2-Check the status of the device visually.

3-Check the safety system of the heating system if it is working properly. Heat limit and safety

thermostats artificially and check that they are functioning.

4-Check all electricity connections of the device. Fasten any loosened cables.

5-Check the operation of resistances with required measurement  equipment.

6-Check the hot water production efficiency as flow and temperature.

7-Check the general operation of the device.

CAUTION!:

 Especially during winter, when the ambiant temperature decreases below 0°C 

there is a risk of freezing and the system water must be drained if the electrical connection of 

the device is interrupted during these periods.

WARNING! : 

Make sure to cut off the electricity from the short circuit relay before making 

any maintenance or repair on the boiler.

16

Содержание Omega 6

Страница 1: ...rev no 01 05 2018...

Страница 2: ...NS 10 3 7 FILLING WATER TO THE SYSTEM 11 3 8 STARTING UP 11 3 8 1 PRE CONTROLS BEFORE STARTING UP 11 3 8 2 FIRST OPERATION 11 3 8 3 CIRCULATION PUMP PRESSURE CURVE 12 4 FEATURES OF OMEGA ELECTRIC BOIL...

Страница 3: ...d this guide carefully This guide is an important source of installation and technical features that you can benefit from It is very important for you autorized services in terms of the information it...

Страница 4: ...ation Damage to the furniture or floor or animals resulted from falling objects from device because of vibration Do not climb on the device Personel injury as a result of falling down with device or f...

Страница 5: ...ators connected to the system and provides hot water by heat exchanger Installation and services must be in accordance with recent standarts and announced directives Our company is not responsible for...

Страница 6: ...2 2 COMPONENTS OF THE BOILER 5...

Страница 7: ...ere is no hot water production even when the hot water tap is opened TEST Mode of adjustment by AUTORISED SERVICE during first installation or maintance Users should not use this position during opera...

Страница 8: ...rgy cable dimensions should be chosen from the technical specifications table in this manual and must be connected by a qualified electrician WARNING Do not operate the boiler before venting the air f...

Страница 9: ...ace must be left around the for the authorized service to intervene in the event of a technical breakdown or maintenance You can find the minimum spaces required for installation in the below diagram...

Страница 10: ...e above the capacity of the pump must be avoided You can see the pump capacities from the pump pressure curve When there is a pressure increase at heating system the security ventile operates in order...

Страница 11: ...OLS BEFORE STARTING UP A Make sure all air is vented from the system radiators and the boiler and all air vents are closed B Check the system pressure from the manometer Must be 1 2 1 5 bars C Remove...

Страница 12: ...ega Boiler Circulation pump has 3 speed options You can choose the required pump speed according to the resistance of your installation You can use the below diagram for deciding the pump speed Water...

Страница 13: ...an quickly enter the regime and heat the house Protection against high pressures with 3 bar safety valve Manometer 3 stage circulation pump 1 bar set safety switch protection againts running without w...

Страница 14: ...5 TECHNICAL TABLE 13...

Страница 15: ...6 ELECTRICITY CONNECTION DIAGRAM 14...

Страница 16: ...r the boiler will not operate and the H3 warning code will appear on the digital display preventing damage which causes from running without water What to Do The heating system pressure is increased b...

Страница 17: ...ves are switched off there is an automatic by pass system in order to provide of passing of minimum water flow in order to prevent rapid over heating of the boiler 8 MAINTENANCE We recommend that the...

Страница 18: ...ansport 7 Damages caused by the use of lime water in hot water circulation ideal water hardness will be 15 20 French hardness 8 First operation and interventions by people other than the authorized se...

Страница 19: ......

Отзывы: