HEAT CALIBRATION 

The sensors of MT 150 SET Room Controls are very sensitive in comparison to domestic 
thermometers. If you would like to refer to your domestic thermometer, please calibrate your room 
control.  

-

 

When the unit is off, please press  “

” for 3 seconds. 

 

Please adjust temprature difference by using + and – buttons in order to calibrate the device. 
This value can be set between -8 and +8.  

 

Press “

” 4 times to exit the menu 

Warning:

 Recommended heat calibration value is  “

 

 

IN TRODUCTION OF ROOM CONTROL TO THE RECEIVER  

Each room control is defined with its own receiver. In case of a loss of signal, you can make an 
introduction by following the below steps. Do not attempt this unless needed. 

-

 

 Open the cover on the receiver. 

 

After energy is provided to the receiver, press IP_SET button on the receiver. 

 

When wireless room control is in OFF position, press 

 button for 3 seconds. The menu for 

heat calibration settings will appear. If 

 is pressed again, the serial number of room 

control will appear.   

 

Next, press “+” or “-“. The flashing green led on the receiver will be constant and there will 
be a warning sound from the receiver. 

 

Now the room control and the receiver are introduced to each other. 

 

Press “

” 4 times to exit the menu 

 

DIMENSIONS  

Thermostat dimension : 80 mm×80 mm×25 mm 

 

Receiver dimension. 86 mm × 86 mm × 23 mm 

 