5. REGULATOR FUNCTIONS.
The regulator is equipped with a number of functions that, together with the possibility of creating
your own program, enable adjusting the regulator's work to the individual needs of the user. Some
of the functions listed below are activated after the appropriate programming of the regulator
(
see section and section 9.
).
1.
Continuous temperature measurement function
, regardless of whether the regulator is on
(it must be connected to the power supply)
–
parameter
d1
is set to 1.
2.
The function of controlling the refrigeration system (chiller)
, depending on the measured
temperature
–
parameter
C9
is set to the value 0.
3.
Light signaling function for switching on the cooling / heating operation
–
blue LED is on.
4.
Control function of the heating system
, depending on the measured temperature
–
parameter
C9
is set to 1.
5.
The stirrer or ventilator control function
, enabling the implementation of the following variants
of this control
–
depending on the
F0
parameter settings:
a.
automatic operation:
−
cyclic operation of the stirrer / ventilator, independent of the operating condition of the
chiller (unit) / heating system,
−
stirrer operates continuously during the operation of the chiller (unit), when the chiller
is switched off, the stirrer goes into cyclic operation,
−
stirrer / ventilator operates only when the chiller / heating system is switched on,
−
continuous stirrer / ventilator operation while the regulator's operation is on (main
application in dryers),
−
switched off stirrer / ventilator operation,
b.
operation triggered manually:
−
switching on continuous stirrer / ventilator operation, regardless of whether the control
operation of the regulator is switched on; in order to end the stirrer operation, press
the button
[3]
,
−
switching on the stirrer / ventilator operation for a strictly defined time, regardless
of whether the control work of the regulator is switched on.
6.
Blocking function of the stirrer and the chiller (unit) when the flap of the milk cooler tank
opens
(actuation of the limit switch)
–
parameter
AF
. In dryers it can be used to turn off the
ventilator, e.g. when the door is opened.
7.
Defining the operation of the limit switch as negative or positive
–
parameter
UU
.
8.
The chiller (unit) operation supervision function
, consisting in the possibility of setting
the maximum and minimum operation time of the chiller (unit), as well as its minimum standstill
time
–
parameters
E1
and
E2
.
9.
The function of registering the maximum and minimum temperature values throughout
the regulator's working cycle
. This function is connected with the possibility of temporally