P 7 / 7

High Voltage Countries and Areas
where Noise Suppression is Not Required

Fig. 16

W

iring diagram

[3] Handle Portion of Motor Housing

Pilot lamp

Noise suppressor (if used)

Switch

Line filter (if used)

Rib

Be careful not to route the lead wires (black)
of Noise suppressor over the ribs.

Fix lead wire (clear) of Noise suppressor
with the lead wire holders.

Lead wire holder

Fix the  two lead wires
from Support complete
with the lead wire holder,
and be sure that they are
are tight in this portion.

Terminal block

Содержание UT2204

Страница 1: ...f tool holder portion Double insulation Net weight kg lbs Power supply cord m ft No load speed min 1 rpm Max blade diameter mm 550 Yes M12 220 Europe 4 0 13 1 Other countries 2 5 8 2 3 7 8 2 Wrench 13...

Страница 2: ...gear housing and tap the shaft portion with a plastic hammer Fig 1 4 Fix Gear housing in vise and remove Bearing retainer 22 36 by turning clockwise with Adjustable bearing retainer wrench No 1R316 F...

Страница 3: ...d unscrew four 5x40 Tapping screws that fasten Gear housing to Motor housing 3 Separate Gear housing from Gear housing cover complete Fig 1 4 From Motor housing separate Gear housing cover complete to...

Страница 4: ...Orange Clear Heat shrink tube Fig 10 Fig 11 Circuit diagram Wiring diagram Heat shrink tube Insert Heat shrink tube polyolefin tube through the lead wire clear and connect Earth terminal with the lead...

Страница 5: ...be Lead Wire clear Noise Suppressor Earth terminal Field Terminal block Choke Coil Pilot lamp Lead wire holder Earth terminal Motor Housing Rib Switch Be careful not to route the lead wires black of N...

Страница 6: ...agram As illustrated in Fig 15 route the two lead wires white from Support complete through Line filter before connecting to Switch and Terminal block Line filter Noise suppressor is not used for some...

Страница 7: ...suppressor if used Switch Line filter if used Rib Be careful not to route the lead wires black of Noise suppressor over the ribs Fix lead wire clear of Noise suppressor with the lead wire holders Lea...

Отзывы: