CAUTION 

 

Repair the machine in accordance with "Instruction manual" or "Safety instructions". 

Follow the instructions described below in advance before repairing: 

 

Wear ESD Anti-static electronics gloves. 

 

In order to avoid wrong reassembly, draw or write down where and how the parts are assembled, and what the parts are. 

It is also recommended to have boxes ready to keep disassembled parts by group. 

 

Handle the disassembled parts carefully. Clean and wash them properly. 

 

Remove Battery, except when it is necessary to check the operation of machine. 

 

 

This model is part-replaceable only for Window frame (Lens), Keypad (Switch), Screws, Labels and DC Jack cover. 

 

If all lasers do not light up, you may be able to repair with a switch-change, but you will not be able to repair if some 

lasers do not light up. Prior to repair, understand the symptom of the trouble and determine whether the REPAIR is 

feasible or not. 

 

The label covering the head of the screw holes is stuck. Arrange the label for repair. 

 

Model SK106D and SK106GD are laser adjustable. Refer to the dedicated manual for the laser adjustment method. 

 

The screws are shipped in units of 10 pcs. 

 

Window frame (Lens) contains Screws (4 pcs) and Label. 

 
 

3

 

NECESSARY REPAIRING TOOLS 

 

Description 

Use for 

T8 Hexalobular driver 

assembling Main housing 

T6 Hexalobular driver 

assembling Window frame (Lens) and Battery holder 

Slotted screwdriver 

removing Label 

 
 

4

 

TIGHTENING TORQUE SPECIFICATIONS 

 

Fastener 

Tightening torque (N∙m) 

T6 Tapping screw 

0.3±0.03 

T8 Tapping screw 

0.4±0.03 

Содержание SK105D

Страница 1: ...December 2019 Ver 1 OFFICIAL USE For ASC CORDLESS CROSS LINE LASER SK105D SK105GD SK106D SK106GD REPAIR MANUAL...

Страница 2: ...5 1 Window frame section 4 5 1 1 Disassembling Assembling of Window frame 4 5 2 DC Jack cover 5 5 2 1 Disassembling Assembling of DC Jack cover 5 5 3 Housing section 5 5 3 1 Disassembling Assembling o...

Страница 3: ...f all lasers do not light up you may be able to repair with a switch change but you will not be able to repair if some lasers do not light up Prior to repair understand the symptom of the trouble and...

Страница 4: ...move Front label indicated by the red circle then remove Screw 2 Remove the adhesive residue and stick a new Front label when assembling Fig 2 3 Remove 2x8 Tapping screws 4 pcs with T6 screwdriver 4 T...

Страница 5: ...en assembling 5 3 Housing section 5 3 1 Disassembling Assembling of Battery terminal Fig 5 1 Remove 2x8 Tapping screws 2 pcs with T6 screwdriver 2 Tighten them with a torque of 0 3 N m when assembling...

Страница 6: ...s time be careful not to cut Keypad cable indicated with the arrow 6 One side of Keypad cable is integrated with Keypad Switch that is glued on Main housing and the other is connected Control board 7...

Страница 7: ...board beforehand and then replace Keypad switch 2 Keypad Switch is peeled off because it is glued with an adhesive 3 Remove the adhesive when assembling Keypad Switch 4 When assembling Keypad Switch p...

Отзывы: