5. OPERATING PROCEDURES
−
11
−
ENGLISH
(1) Make sure that the
AC circuit breaker
is off.
(2) Turn the fuel cock to the vertical
(open) position
(3) Turn the key switch to the
"
START
"
position.
If the engine won't start, turn the
switch back to
"RUN"
position and then
wait for approximately 10 seconds to
try it again.
NOTE :
■
You might have to keep the starter
running for at least 3 to 5 seconds,
since the engine incorporates the
mechanism in it where the ignition
circuit is activated by the increase of
hydraulic pressure.
■
In the following occasion, two or three
trials may be required for starting the
engine :
a. The very first starting of a new
generator.
b. After the refueling of the engine
which has been stopped due to fuel
shortage.
c. Starting after the oil filter change.
d. Warm the engine up for a minute or
two. Longer time would be needed in
cold weather.
START
RUN
START
STOP
RUN
STOP
STARTING
CLOSE
CLOSE
OPEN
■
Check the oil level before each operations. (See page 6)
■
Perform the specified Daily Inspection to see if it is in normal condition.
[
CAUTION
]
ON
OFF
G12000R(CSA)̲GU2044 05.1.20 1:29 PM ページ11