P
3
/
10
R
epair
Air cleaner cover
Refueling winding
1. Remove Air cleaner cover by unscrewing M5x14 Pan head screw.
Then remove Refueling winding from Carburetor.
2. While sliding down Sheath of Refueling winding
to expose the inner cable, remove the stopper from
Refueling handle group along the curve.
M5x14 Pan head screw
3. Remove Pan head screw and separate Refueling handle group
from Handle.
Sheath of Refueling winding
Stopper of Refueling winding
Refueling handle group
Refueling handle
group
Curve
(2) Remove Refueling winding from Refueling handle group and from Carburetor as drawn in
Fig. 2
.
Fig. 2
Refueling winding
[3] DISASSEMBLY/ASSEMBLY
[3] -1. Pump Section (cont.)
DISASSEMBLING
Pan head screw