background image

20 ENGLISH

Troubleshooting for wireless activation function

Before asking for repairs, conduct your own inspection first. If you find a problem that is not explained in the manual, 

do not attempt to dismantle the tool. Instead, ask Makita Authorized Service Centers, always using Makita replace

-

ment parts for repairs.

State of abnormality

Probable cause (malfunction)

Remedy

The wireless activation lamp does 

not light/blink.

The wireless unit is not installed into 

the tool. 

The wireless unit is improperly installed 

into the tool.

Install the wireless unit correctly.

The terminal of the wireless unit and/or 

the slot is dirty.

Gently wipe off dust and dirt on the terminal of the 

wireless unit and clean the slot.

The wireless activation button on the 

tool has not been pushed.

Push the wireless activation button on the tool 

briefly.

The stand-by switch on the vacuum 

cleaner is not set to "AUTO".

Set the stand-by switch on the vacuum cleaner to 

"AUTO".

No power supply

Supply the power to the tool and the vacuum 

cleaner.

Cannot finish tool registration / can

-

celling tool registration successfully.

The wireless unit is not installed into 

the tool. 

The wireless unit is improperly installed 

into the tool.

Install the wireless unit correctly.

The terminal of the wireless unit and/or 

the slot is dirty.

Gently wipe off dust and dirt on the terminal of the 

wireless unit and clean the slot.

The stand-by switch on the vacuum 

cleaner is not set to "AUTO".

Set the stand-by switch on the vacuum cleaner to 

"AUTO".

No power supply

Supply the power to the tool and the vacuum 

cleaner.

Incorrect operation

Push the wireless activation button briefly and 

perform the tool registration/cancellation procedures 

again.

The tool and vacuum cleaner is away 

from each other (out of the transmission 

range).

Get the tool and vacuum cleaner closer to each 

other. The maximum transmission distance is 

approximately 10 m however it may vary according 

to the circumstances.

Before finishing the tool registration/

cancellation; 

- the switch trigger on the tool is pulled 

or;  

- the power button on the vacuum 

cleaner is turned on.

Push the wireless activation button briefly and 

perform the tool registration/cancellation procedures 

again.

The tool registration procedures for the 

tool or vacuum cleaner has not finished.

Perform the tool registration procedures for both the 

tool and the vacuum cleaner at the same timing.

Radio disturbance by other appliances 

which generate high-intensity radio 

waves.

Keep the tool and vacuum cleaner away from the 

appliances such as Wi-Fi devices and microwave 

ovens.

Содержание DHR400PT2

Страница 1: ...INSTRUCTION MANUAL Cordless Rotary Hammer DHR400 ENGLISH Original instructions Read before use ...

Страница 2: ... their life must be col lected separately and returned to an envi ronmentally compatible recycling facility Intended use The tool is intended for hammer drilling and drilling in brick concrete and stone as well as for chiselling work Noise The typical A weighted noise level determined accord ing to EN60745 Sound pressure level LpA 91 dB A Sound power level LWA 102 dB A Uncertainty K 3 dB A WARNING...

Страница 3: ...r medical devices should contact the maker of their device and or doctor for advice before operating this power tool Personal Safety 1 Stay alert watch what you are doing and use common sense when operating a power tool Do not use a power tool while you are tired or under the influence of drugs alcohol or med ication A moment of inattention while operating power tools may result in serious persona...

Страница 4: ...nother Shorting the battery termi nals together may cause burns or a fire 4 Under abusive conditions liquid may be ejected from the battery avoid contact If con tact accidentally occurs flush with water If liquid contacts eyes additionally seek medical help Liquid ejected from the battery may cause irritation or burns 5 Do not use a battery pack or tool that is dam aged or modified Damaged or modi...

Страница 5: ...battery 10 The contained lithium ion batteries are subject to the Dangerous Goods Legislation require ments For commercial transports e g by third parties forwarding agents special requirement on pack aging and labeling must be observed For preparation of the item being shipped consult ing an expert for hazardous material is required Please also observe possibly more detailed national regulations ...

Страница 6: ...ess unit keep it in the supplied case or a static free container 25 Do not insert any devices other than Makita wireless unit into the slot on the tool 26 Do not use the tool with the lid of the slot dam aged Water dust and dirt come into the slot may cause malfunction 27 Do not pull and or twist the lid of the slot more than necessary Restore the lid if it comes off from the tool 28 Replace the l...

Страница 7: ...he tool automat ically stops without any indication In this situation turn the tool off and stop the application that caused the tool to become overloaded Then turn the tool on to restart Overheat protection When the tool or battery is overheated the tool stops automatically and the lamp blinks In this case let the tool and battery cool before turning the tool on again Overdischarge protection Whe...

Страница 8: ...n under no load Once operation starts with a bit against concrete blows per minute increase and reach the numbers as shown in the table When temperature is low and there is less fluidity in grease the tool may not have this function even with the motor rotating Lighting up the front lamp 1 1 Lamp CAUTION Do not look in the light or see the source of light directly Pull the switch trigger to light ...

Страница 9: ...en under load condition ASSEMBLY CAUTION Always be sure that the tool is switched off and the battery cartridge is removed before carrying out any work on the tool Side handle CAUTION Use the side handle only when chipping scaling or demolishing Do not use it when drilling in concrete masonry etc The tool cannot be held properly with this side handle when drilling 1 2 1 Side handle 2 Clamp nut The...

Страница 10: ...nstalling the drill bit always make sure that the drill bit is securely held in place by trying to pull it out 1 1 Drill bit To remove the drill bit pull the chuck cover down all the way and pull the drill bit out 1 2 1 Drill bit 2 Chuck cover Chisel angle when chipping scaling or demolishing The chisel can be secured at the desired angle To change the chisel angle rotate the action mode chang ing...

Страница 11: ...depth gauge NOTE Make sure that the depth gauge does not touch the main body of the tool when attaching it Dust extractor attachment Optional accessory Installing the dust extractor attachment 1 Loosen the side grip on the tool 2 Install the dust cover so that the claws of the dust cover fit in the grooves between the tool and the side grip 1 2 3 1 Dust cover 2 Claw 3 Groove 3 Tighten the side gri...

Страница 12: ...tack two bellows attach the depth gauge extension to the depth gauge 1 1 Depth gauge extension Dust extractor attachment for hammering only Optional accessory 1 Install the hose holder When the side handle is installed to tool loosen the clamp nut and then remove the hex bolt Install the hose holder with the hex bolt and the clamp nut by tightening the clamp nut firmly 1 2 3 1 Bolt 2 Hose holder 3...

Страница 13: ...ool and then fix the hose to the hose holders 1 2 3 3 1 Dust cover 2 Hose 3 Hose holder 4 Connect the hose to the hose of the vacuum cleaner with the hose joint NOTE If the hose is not included attach the dust cover to the cleaner s joint or attach it to Makita s hose ø28 5 Adjust the distance between the dust cover and the tip of the chisel or bull point The recommended distance is 30 mm to 100 m...

Страница 14: ...of control of the tool and potentially severe injury Set the action mode changing knob to the symbol Position the drill bit at the desired location for the hole then pull the switch trigger Do not force the tool Light pressure gives best results Keep the tool in position and prevent it from slipping away from the hole Do not apply more pressure when the hole becomes clogged with chips or particles...

Страница 15: ...essory CAUTION Place the tool on a flat and stable surface when installing the wireless unit NOTICE Clean the dust and dirt on the tool before installing the wireless unit Dust or dirt may cause malfunction if it comes into the slot of the wireless unit NOTICE To prevent the malfunction caused by static touch a static discharging material such as a metal part of the tool before picking up the wire...

Страница 16: ...itch trigger or turn on the power switch on the vacuum cleaner NOTE Refer to the instruction manual of the vacuum cleaner too If you wish to activate the vacuum cleaner along with the switch operation of the tool finish the tool registra tion beforehand 1 Install the batteries to the vacuum cleaner and the tool 2 Set the stand by switch on the vacuum cleaner to AUTO 1 1 Stand by switch 3 Press the...

Страница 17: ...m cleaner to AUTO 1 1 Stand by switch 4 Push the wireless activation button on the tool briefly The wireless activation lamp will blink in blue 1 2 1 Wireless activation button 2 Wireless activation lamp 5 Pull the switch trigger of the tool Check if the vacuum cleaner runs while the switch trigger is being pulled To stop the wireless activation of the vacuum cleaner push the wireless activation b...

Страница 18: ...uum cleaner is available and the tool is running Tool registration Green 20 seconds Ready for the tool registration Waiting for the registration by the vacuum cleaner 2 seconds The tool registration has been finished The wireless activation lamp will start blinking in blue Cancelling tool registration Red 20 seconds Ready for the cancellation of the tool registration Waiting for the cancellation b...

Страница 19: ...nd then become red After that press the wireless activation button on the tool in the same way 1 2 1 2 1 Wireless activation button 2 Wireless activation lamp If the cancellation is performed successfully the wire less activation lamps will light up in red for 2 seconds and start blinking in blue NOTE The wireless activation lamps finish blinking in red after 20 seconds elapsed Press the wireless ...

Страница 20: ...led into the tool Install the wireless unit correctly The terminal of the wireless unit and or the slot is dirty Gently wipe off dust and dirt on the terminal of the wireless unit and clean the slot The stand by switch on the vacuum cleaner is not set to AUTO Set the stand by switch on the vacuum cleaner to AUTO No power supply Supply the power to the tool and the vacuum cleaner Incorrect operatio...

Страница 21: ...ner away from the appliances such as Wi Fi devices and microwave ovens The vacuum cleaner runs while the tool s switch trigger is not pulled Other users are using the wireless activation of the vacuum cleaner with their tools Turn off the wireless activation button of the other tools or cancel the tool registration of the other tools MAINTENANCE CAUTION Always be sure that the tool is switched off...

Страница 22: ...22 ...

Страница 23: ...23 ...

Страница 24: ...www makita com Makita Europe N V Makita Corporation 3 11 8 Sumiyoshi cho Anjo Aichi 446 8502 Japan Jan Baptist Vinkstraat 2 3070 Kortenberg Belgium 885622 221 EN 20170913 ...

Отзывы: