background image

13 ENGLISH

Wall mount for cordless cleaner

Optional accessory

NOTE:

 The screw to mount the holder is not included. 

Prepare a screw which fits with the material to screw 

into.

Attach the wall mount for cordless cleaner to a hard 

wooden wall, beam or column, where the wall mount 

for cordless cleaner can be firmly secured. Always be 

sure that the wall mount for cordless cleaner is securely 

attached before hanging the cleaner.

1

►    

1.

 Wall mount for cordless cleaner

CAUTION:

 

Do not hang the cleaner to the wall 

mount violently or hang other appliances than the 

cleaner.

Troubleshooting

Before asking for repairs, check the following points.

Symptom

Area to be investigated

Fixing method

Weak suction power

Is the capsule full of dust?

Empty the capsule of dust.

Is the filter clogged?

Clean or wash the filter.

Is the battery cartridge discharged?

Charge the battery cartridge.

Not working

Is the battery cartridge discharged?

Charge the battery cartridge.

CAUTION:

 

Do not attempt to repair the cleaner by yourself.

OPTIONAL 

ACCESSORIES

CAUTION:

 

These accessories or attachments 

are recommended for use with your Makita tool 

specified in this manual.

 The use of any other 

accessories or attachments might present a risk of 

injury to persons. Only use accessory or attachment 

for its stated purpose.

If you need any assistance for more details regard-

ing these accessories, ask your local Makita Service 

Center.
• 

Extension wand (Straight pipe)

• Nozzle
• 

Nozzle for carpet

• 

Shelf brush

• 

Corner nozzle

• 

Round brush

• 

Flexible hose

• Filter

• 

Prefilter

• 

High performance filter

• 

HEPA filter

• 

Free nozzle

• 

Seat nozzle

• 

Crevice nozzle

• 

Wall mount for cordless cleaner

• 

Cyclone attachment

• 

Tool bag

• 

Makita genuine battery and charger

NOTE:

 Some items in the list may be included in the 

tool package as standard accessories. They may 

differ from country to country.

Содержание CL001GZ04

Страница 1: ...INSTRUCTION MANUAL Cordless Cleaner CL001G ENGLISH Original instructions Read before use ...

Страница 2: ... min Overall length with battery BL4025 1 066 mm Rated voltage D C 36 V 40 V max Net weight 1 7 2 3 kg Due to our continuing program of research and development the specifications herein are subject to change without notice Specifications may differ from country to country The weight does not include accessories but battery cartridge s The lightest and heaviest combination weight of the appliance ...

Страница 3: ... use in areas where they may be present 11 Use only the charger supplied by the manufac turer to recharge 12 Do not pick up anything that is burning or smok ing such as cigarettes matches or hot ashes 13 Do not use without dust bag and or filters in place 14 Do not charge the battery outdoors 15 Recharge only with the charger specified by the manufacturer A charger that is suitable for one type of...

Страница 4: ...Please also observe possibly more detailed national regulations Tape or mask off open contacts and pack up the battery in such a manner that it cannot move around in the packaging 11 When disposing the battery cartridge remove it from the tool and dispose of it in a safe place Follow your local regulations relating to disposal of battery 12 Use the batteries only with the products specified by Mak...

Страница 5: ...locked completely CAUTION Always install the battery cartridge fully until the red indicator cannot be seen If not it may accidentally fall out of the tool causing injury to you or someone around you CAUTION Do not install the battery cartridge forcibly If the cartridge does not slide in easily it is not being inserted correctly Battery protection system The tool is equipped with a tool battery pr...

Страница 6: ...OTE You can change the suction power before turning on the cleaner NOTE The cleaner starts the operation with the same suction power as the last operation Lighting up the lamp CAUTION Do not look in the light or see the source of light directly To turn on the lamp push the suction power change button The lamp goes off in approximately 10 seconds While the cleaner is running the lamp turns on The l...

Страница 7: ...rmance filter with the stay 1 1 Stay Disposing of dust CAUTION Empty the cleaner before it becomes too full or the suction force weakens CAUTION Be sure to empty the inside of the cleaner itself of dust Failure to do so may cause the filter to be clogged or the motor to be damaged In order to drop dust sticking on the filter in the capsule tap the capsule 4 or 5 times with your hand 2 1 1 Capsule ...

Страница 8: ...ck that high perfor mance filter is loaded correctly prior to using cleaner If they are not loaded correctly dust will get into the motor housing and cause motor failure If the problem as described later occurs high per formance filter is not loaded correctly Reload them correctly to rectify problem Attach the capsule Align the mark on capsule with the mark on the handle and then firmly twist caps...

Страница 9: ...ce filter on the HEPA filter and twist it to secure To remove follow the instal lation procedure in reverse 1 2 1 HEPA filter 2 Prefilter 1 2 1 HEPA filter 2 High performance filter OPERATION CAUTION Do not move your face close to the air vent when operating the cleaner If foreign objects are blown into eyes it may result in personal injury Installing or removing the cleaner attachment CAUTION Aft...

Страница 10: ...to secure the connection during use To disconnect the attachment twist and extract it also in direction of the arrow If the attachment is twisted in the opposite direction the capsule may become loose Cleaning Suction Nozzle Attach the nozzle to clean off tables desks furniture etc The nozzle slips on easily 1 1 Nozzle Nozzle Extension wand Straight pipe The extension wand fits in between the nozz...

Страница 11: ...e You can pick up powder and dust without nozzle For picking up dust on a floor in a standing position it is convenient to attach the extension wand to the cleaner 1 1 Extension wand MAINTENANCE CAUTION Always be sure that the tool is switched off and the battery cartridge is removed before attempting to perform inspection or maintenance To maintain product SAFETY and RELIABILITY repairs any other...

Страница 12: ...rmance filter Wash the filter in soapy water when it is clogged with dust and the cleaner power becomes weak Dry it out thoroughly before use HEPA filter Optional accessory NOTICE Do not rub or scratch the HEPA filter with hard objects such as a brush and a paddle Clogged HEPA filter cause poor suction performance Clean out the filter from time to time Occasionally wash the HEPA filter in water ri...

Страница 13: ...battery cartridge discharged Charge the battery cartridge Not working Is the battery cartridge discharged Charge the battery cartridge CAUTION Do not attempt to repair the cleaner by yourself OPTIONAL ACCESSORIES CAUTION These accessories or attachments are recommended for use with your Makita tool specified in this manual The use of any other accessories or attachments might present a risk of inj...

Страница 14: ...d NOTICE Always use the cleaner with the filters installed even when using the cyclone attach ment Using the cleaner without the filters installed may result in a motor malfunction NOTE Check that the cyclone attachment cleaner and straight pipe are locked properly before use NOTE Empty the dust case of the cyclone attach ment and the capsule of the cleaner when dust has accumulated Continued use ...

Страница 15: ...is clogged remove and wash them with water Refer to Disposing of dust for the removal procedure Dry the parts thoroughly before reinstallation and use 2 1 1 Dust case 2 Mesh filter When the mesh filter gets dirty badly clean it in the following procedures 1 Turn the mesh filter counterclockwise and remove it while the hooks are unlocked 1 2 1 Mesh filter 2 Hook 2 Remove the dust on the mesh filter...

Страница 16: ...www makita com Makita Europe N V Makita Corporation 3 11 8 Sumiyoshi cho Anjo Aichi 446 8502 Japan Jan Baptist Vinkstraat 2 3070 Kortenberg Belgium 885886 227 EN 20210113 ...

Отзывы: