LIMITED WARRANTY

 

 
 

In  order  to  take  advantage  of  the  MAKINEX  limited  warranty,  you  must  have 
maintenance  performed  according  to 

the  schedule  (contained  in  relevant  owner’s 

manual supplied with this product), by an authorised MAKINEX dealer or MAKINEX 
service  technician.  You  are  free  to  have  your  MAKINEX  product  serviced  by  any 
suitably qualified mechanic or electrician (depending on the mechanical or electrical 
requirement) and this will not affect your statutory warranties, however, failure by the 
owner  to  have  the  recommended  servicing  carried  out  by  an  authorised  MAKINEX 
dealer/service  technician  means  that  you  cannot  take  advantage  of  the  MAKINEX 
limited warranty. 
 
In  order  to  ensure  your  safety,  we  strongly  recommend  that  you  only  use  an 
authorised  MAKINEX  dealer  for  servicing.  Only  authorised  MAKINEX  dealers  have 
access  to  all  the  special  tools,  technical  information,  parts  and  training  required  to 
maintain your MAKINEX product in peak operating condition. 

MAKINEX  warrants  each  new  Generator  to  be  free  from  defects  in  material  and 
workmanship  under  normal  domestic  and  industrial  use  and  service  for  the  period 
specified  below,  conditional  to  the  limitations  and  exclusions  printed  on  this  page. 
This warranty applies only to new MAKINEX generator distributed by us and by our 
authorised MAKINEX dealers. 

 

WARRANTY: (Ex-factory/ Reseller premise) 

MAKINEX warrants to the original purchaser: 

o

  Frame and all Electrical components will be free of defects in material 

and workmanship for a period of one (1) year from the original date of 
purchase.  

o

  Honda GX Engine is subject to (3) years warranty. Please see 

www.hondapowerequipment.com for details. 

o

  3 years warranty on RFL alternators 

o

  1 year warranty for electrical components 

o

  6 months warranty for battery 

 

WARRANTY EXCLUSIONS 

This warranty does not cover the following repairs and equipment: 

NORMAL WEAR 

Generator needs periodic parts and service to perform well. This warranty does not 
cover repair when normal use has exhausted the life of a part or the equipment as a 
whole. 

Содержание GEN-16P-US-208

Страница 1: ...Page 1 of 26 OPERATOR S MANUAL Makinex 16kW 3 Phase Generator Model GEN 16P US 208 GEN 16P US 240 GEN 16P US 480 Rev 1117...

Страница 2: ...X50A 2X30A 2X20A OUTLET WITH GFCI PROTECTION 11 FEATURES 11 OVERALL MACHINE DIMENSIONS 12 ALTERNATOR SPECIFICATIONS 12 OPERATION 14 BEFORE USE 14 ADDING FUEL 15 OPERATING GENERATOR 16 CONNECTING ELECT...

Страница 3: ...rt of this publication may be reproduced in any form or by any means electronic or mechanical including photocopying without express written permission from MAKINEX Any type of reproduction or distrib...

Страница 4: ...ful attention CAUTION CAUTION indicates a potential hazardous situation which if not avoided may result in minor or moderate injury WARNING WARNING indicates a potentially hazardous situation which if...

Страница 5: ...INFORMATION WARNING Read this manual thoroughly before operating your generator Failure to follow instructions could result in serious injury or death WARNING MAKINEX GEN 16P USA Generator designed fo...

Страница 6: ...r explosion can cause severe burns or death ALWAYS switch the engine OFF when refuelling ALWAYS refuel away from any source of heat ALWAYS refuel in a well ventilated area NEVER overfill fill the tank...

Страница 7: ...nents could result in serious burns During operation touch only the control surfaces of generator Keep children away from the generator at all times They may not be able to recognise the hazards of th...

Страница 8: ...d be bolted securely onto an appropriate ground source Portable generators are inherently more dangerous than fixed generators as they are not permanently earthed Therefore appropriate measures must b...

Страница 9: ...cords 2 Use extension cords with a 3 hole receptacle and a 3 prong plug on opposite ends to maintain earth protection from the generator to the appliance We strongly recommend that all applicable fede...

Страница 10: ...Page 10 of 26 SAFETY DECAL May vary by model...

Страница 11: ...s with GFCI protection OR 1x30A 2x20A outlets with GFCI protection 480V WEIGHT 155 kg 344 lbs NOISE LEVEL 7M NO LOAD 72dB 50 LOAD 76dB 100 LOAD 78dB RATED POWER FACTOR 0 8 ENGINE TYPE TWIN CYLINDER AI...

Страница 12: ...Page 12 of 26 OVERALL MACHINE DIMENSIONS ALTERNATOR SPECIFICATIONS 120 208V...

Страница 13: ...Page 13 of 26 120 240V 240 480V...

Страница 14: ...d let it idle for 1 or 2 minutes Stop the engine and wait for 2 or 3 minutes 2 Remove the oil level dipstick and wipe it clean 3 Fully insert the oil level dipstick then remove it to check the oil lev...

Страница 15: ...ADDING FUEL TO GENERATOR OBSERVE THE FOLLOWING STEPS 2 0 Always ensure that fuel tanks are filled outdoors 2 1 Turn generator OFF and let it cool for at least two minutes before removing fuel cap 2 2...

Страница 16: ...ngine switch allowing it to return to the ON position 6 Once the engine has warmed up set the choke lever to the OPEN position CONNECTING ELECTRICAL DEVICES The generator can supply 120V AC through 2...

Страница 17: ...meter is installed on the machine to help with tracking operation hours Refer to Honda GX690 user manual provided at sale for engine related maintenance Should you have questions about replacing compo...

Страница 18: ...flammable and explosive Fire or explosion from misuse of fuel can cause severe burns and even death To protect against rust formation during storage oil the cylinder bore 1 Remove spark plugs and pou...

Страница 19: ...intain your MAKINEX product in peak operating condition MAKINEX warrants each new Generator to be free from defects in material and workmanship under normal domestic and industrial use and service for...

Страница 20: ...etc Accessory parts such as starting batteries and storage covers Failures due to acts of God and other force majeure events beyond the manufacturer s control Problems cause by parts that are not orig...

Страница 21: ...territories only e g Australian units will be delivered within Australian territory USA units will be delivered within USA territory and European units will be delivered within its designated country...

Страница 22: ...ina Avenue Suite 1310 Redondo Beach CA 90277 USA TEL 855 625 4639 EMAIL service makinex com EUROPE TEL 31 0 6 24881203 or 31 0 6 50841849 EMAIL info mtools eu ADDRESS Rietdijk 4 3994 AJ Houten The Net...

Страница 23: ...POSSIBLE MINOR BURNS FROM MAINS ELECTRICAL CONNECTIONS ON GENERATOR 3 UNLIKELY 1 FATALITY 2 HIGH ENSURE THAT NO PART OF BODY IS IN CONTACT WITH TERMINALS WHEN STARTING USING GENERATOR 3 0 ERGONOMIC IN...

Страница 24: ...Page 24 of 26 APPENDIX B WIRING DIAGRAMS 208V WIRING DIAGRAM...

Страница 25: ...Page 25 of 26 480V WIRING DIAGRAM...

Страница 26: ...Page 26 of 26...

Отзывы: