Introduction
Application
The MAKESafe Power Tool Brake is a
safety device that provides accidental
restart protection, motor braking, and
emergency stop functions to stationary
power tools and machinery.
Compatibility
This safety device is not compatible with all
power tools. Please complete the included
compatibility checklist below before
installing this device.
Glossary
●
Power Tool
- the tool or machinery that
you intend to use this brake with.
●
Brake (noun)
- The MAKESafe Power
Tool Brake.
●
Brake (verb)
- The act of decelerating a
power tool.
●
Control Panel
- The provided remote
enclosure with start, stop, and e-stop
buttons.
●
Business End
- The part of the power
tool that performs an operation on a work
piece (i.e. saw blade, grinding wheel,
etc.).
Specifications
PTB-V120-P1
PTB-V240-P1
PTB-V240-P3
Rated Input Voltage
120 VAC
1 PH, 60Hz
(50 Hz options available)
240 VAC
1 PH, 60Hz
(50 Hz options available)
240 VAC
3 PH, 60Hz
(50 Hz options available)
Rated Horsepower (UL508)
1.5 HP
3.0 HP
5.0 HP
Rated Current (UL508)
20 A
17 A
15 A
Approvals
UL508: Industrial Control Devices
CSA #14-13: Industrial Control Equipment
LISTING NUMBER: E114885
Control Voltage
5 VDC
Control Current
< 100mA
Dimensions
(main enclosure)
7.25” L x 5.0” W x 2.22" H
(185 mm x 127 mm x 57 mm)
Dimensions
(standard control panel)
4.1” x 2.2” x 0.9” in.
(105 mm x 57 mm x 23 mm)
Weight
3 lbs
(1.4 kg)
3.3 lbs
(1.5 kg)
Rated Output Voltage (motoring)
120VAC
240VAC
240VAC
Rated Output Voltages (braking)
0 - 90 VDC
0 - 180 VDC
0 - 240 VDC
Plug & Receptacle Type
NEMA 5-15
(custom and international
options available)
NEMA 6-15
(custom and international
options available)
NEMA L15-20
(custom and international
options available)
Notes:
1. This device is only compatible with direct-powered induction motor tools. To verify
compatibility, see included compatibility guide
2. Suitable for connection in the field to a branch circuit rated not more than 20 amperes and
capable of delivering not more than 5,000 rms symmetrical amperes.