![MakerBot Replicator 2X Скачать руководство пользователя страница 3](http://html2.mh-extra.com/html/makerbot/replicator-2x/replicator-2x_how-to-replace_3820397003.webp)
bot.
Push the cable connectors into the body of the bot through the hole in the corner of the bottom
panel. Slide the cables underneath the nearby metal clip.
11. Turn the Replicator 2X upright again.
12. Attach the jumper cable to the Xaxis motor cable.
Your motor cable should be hanging from a metal clip. Attach the male end of the jumper cable
to the motor cable.
13. Attach the jumper cable ends of the new XAxis endstop and motor cable sections to
the frame and gantry.
Find the Xaxis sections of both cables, with the jumper cables attached, inside the front right
corner of the Replicator 2X. Route the cables up through the cable clips. Slide the cables into
the slot at the side of the gantry so that it routes from back to front.
14.
Plug in the jumper cable end of the Xaxis section of the endstop cable.
Push the cable connector on the jumper cable through the rectangular hole in the side of the
gantry and plug it into the endstop.
15. Plug in the jumper cable end of the Xaxis motor cable to the Xaxis motor.
Push the cable connector on the jumper cable through the rectangular hole in the side of the
gantry and plug it into the bottom of the Xaxis motor.
16. Maximize slack on the Xaxis sections of the cables.
Gently tug on the Xaxis sections of the cables where they exits the gantry slot toward the back
of your box. Make sure there is no excess cable between the gantry slot and the endstop/motor.
Then return the metal dowel to the gantry slot. Make sure the slit in the side of the dowel faces
out, away from the cables in the slot, and push the dowel into place with a hex wrench.
17. Route the Y and Zaxis sections of the cable through their cable clips.
Find the Y and Zaxis sections of the cable at the back right corner of the Replicator 2X. Route
the cables up through the cable clips in the back right corner.
18. Plug the Zaxis endstop cable connector into the Zaxis endstop.