3.Installation & Usage of Detector 

3.1 Installing guide to avoid false alarm 

       

A

. Avoid sunshine or strong light 

B

. Using high-pow ered alkaline battery 

C

. Avoid the floating subject, e.g. clothes or curtain, strong w ind may cause false alarming. 

D

. Avoid facing heating unit, such as air conditioner, refrigerator, fan and so on. 

3.2 Installing 

Use screw  to fix the bracket on the w all, about 2.1m to 2.8m from the ground. (PIC3A or PIC3B)  

3.3 Working Mode 

        Detecting Indicator

Detected someone w ithin detecting range, red LED w ill be flashing. 

        Signal transmitting indicator

When transmitting, Green LED w ill be on for. 

        Low  Voltage

When the voltage of battery is low, the Blue LED w ill be alw ays on (indicating: time to 

replace battery). 

        Check when power on

Every time pow er on, detector w ill enter 1 min self-check mode, and the 

Red LED w ill be flashing. If w ithout being triggered, it w ill enter testing mode. 

Code learning mode

Under testing or w orking mode, press code learning sw itch, the Green LED 

w ill be on for 3sec., then enter code learning mode, enter testing mode after 3sec. (PIC5A or PIC4B) 

Selecting working time for detector

Pull to 180S

detector w ill send signal every 180sec. That is 

saving pow er. Pull to 10s

detector w ill send signal every 10sec. That is for installing test.   

3.4 Walk to test 

        Walk into detect range, it should flash once, start transmitting w ireless alarm signal. 

3.5 Code learning 

Firstly, enter code learning status, long press code learning sw itch (PIC5A or PIC4B), Green 

indicator w ill be alw ays on. When mainframe received that signal, it w ill sound to indicating code learning 

finish. If not, please repeat the above operating. 

3.6 EXT Power for AL-413W 

It is able to connect w ith 12V DC Pow er. Please check PIC4A for pow er socket

Default is 

unavailable, unless required by user

 

 

 

 

Содержание AL-2016A

Страница 1: ...1...

Страница 2: ...ic Configure 01 2 Words Explain 02 3 Attention before using 03 4 Feature Function 04 5 Main part instruction 04 6 Setting Operation 10 7 Receive the Alarming phone 19 8 Remote Control Function 21 9 Sy...

Страница 3: ...f Siren Warning time of Siren User Password Password for Disarm or remote control 3 Attention before using 1 Make sure all theArming zones are on duty 2 Avoid heavy impact and unnecessary disassembly...

Страница 4: ...o selectw ired w ireless PIR sensor Door Sensor Gas Smoke Detector and so on 14 12V output port forwired accessories 5 Main part instruction 1 Main unit front 1 Pow er indicator Always on On duty Off...

Страница 5: ...ire directly connect with mainf rame If more than two before connect with mainf rame please connect the detectors in series Wired 3 zone wiring same as above Wired 2 zone wiring same as above Wired 1...

Страница 6: ...ult is 1 when f orgot password please open the cover of mainf rame pull the switchf rom 1 to ON then power off power on after 2sec pull it to be 1 again Password restored to be 000000 1 OFF 2 ON ON Se...

Страница 7: ...7 6 System Setting and Operation Pow er on LCDw ill be on then operating as below NORMAL 1 PHONE 2 CMS 3 P ASSWORD 4 TIME DATE ADVANCED...

Страница 8: ...8 1 LEARN CODE 2 REMOVE...

Страница 9: ...9 3 SETTING 4 SELF CHECK 5 ALARM LOG 6 AUTOARM DISARM...

Страница 10: ...nw ill be warning in any status Except the above two vocal alarming situation If under mute alarm status the sirenw ill notwarn 2 Phone Alarm When alarming the systemw ill dial in order If not being s...

Страница 11: ...r Press 0 key Disarm Sound Bi Bi once Press 1 key ARM Sound Bi once Press 3 key Monitor Local Sound Bi once 9 System Installing 1 Before using allw ireless should learn code Security zone need to be u...

Страница 12: ...12 AL 2016A AL 2016A GSM...

Страница 13: ...0 5sec 13 Security Zone Wireless 80 Wired 4 11 Normal Fault Solution Fault The possible reasons Solution Power LED is OFF LCD screen does notwork Backup batter run out or power is cut Charge the batte...

Страница 14: ...always on Working Method PIC2A Magnetic Stripe abuts against Door Sensor closely and then takes magnetic stripe away more than 20mm LED1 will f lash once sending warning signal Technology Parameter B...

Страница 15: ...3 92MHz Transmitting Distance 200m openv iew place PIR Detector Diagram View PIC2A Sensor Germany Hayman Sensor Detecting angle horizontal 100 Vertical 70 Detecting range 6 12m Size 10 7 5 8 4 7cm Wor...

Страница 16: ...check mode and the Red LEDw ill be flashing If without being triggered it w ill enter testing mode Code learning mode Under testing or working mode press code learning switch the Green LED will be on...

Страница 17: ...7 4 NOTE A Avoid to drop or impacts orw ill cause damage B Avoid touching sensor to keep mirror surface clean C After testing please set to normally work mode D Do regularly checking for better status...

Страница 18: ...18...

Отзывы: