background image

MT750

 

 

INSTRUCTION MANUAL

 

 

DIGITAL CLAMP METER

 

 

MT750 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

Barrier 

It  is  a  part  providing  protection  against  electrical 
shock  and  ensuring  the  minimum  required  air  and 
creep age distances. 

 
 

 

 

 

 

 

 

 
 

1. Specification 

 

Accuracy guaranteed 

100% Or less of range 
Temperature 23 ± 5°C 
Humidity 45 

-

 75% 

 
 

 
ACA

 (Auto Range) 

 

Range 

Accuracy 

40A 

0.00, 0.03

-

41.99A 

±

1.4 %rdg

±

6dgt 

(50/60Hz) 

±

1.6 %rdg

±

6dgt 

(45

-

65Hz) 

400A 

32.0

-

419.9A 

1000A 

320

-

1049A 

Input protective current 

AC1200A 

 

 

ACV

 (Auto Range) 

 

Range 

Accuracy 

4V 

0.000, 0.005

-

4.199V 

±

1.8 %rdg

±

7dgt 

(45

-

65Hz) 

±

2.3 %rdg

±

8dgt 

(65

-

500Hz) 

40V 

3.20

-

41.99V 

400V  32.0

-

419.9V 

600V  320

-

629V 

 

 

DCV 

(Auto Range) 

 

Range 

Accuracy 

400mV 

±

0.0

-

±

419.9mV 

*1 

4V 

±

0.320

-

±

4.199V 

±

1.0%rdg

±

3dgt 

40V 

±

3.20

-

±

41.99V 

400V 

±

32.0

-

±

419.9V 

600V 

±

320

-

±

629V 

 
*1 :    Accuracy is not guaranteed 

 
ACV/DCV / input impedance 

>100M

Ω (400mV Range) 

11M

Ω (4V Range) 

10M

Ω (40/400/600V Range) 

 

Resistance

Auto Range

 

Continuity 

 

Range 

Accuracy 

400

Ω 

0.0

-

419.9

Ω 

±

2.0%rdg

±

4dgt 

4k

Ω 

0.320

-

4.199 k

Ω 

40k

Ω 

3.20

-

41.99 k

Ω 

400k

Ω 

32.0

-

419.9 k

Ω 

4M

Ω 

0.320

-

4.199 M

Ω 

±

4.0%rdg

±

4dgt 

40M

Ω 

3.20

-

41.99 M

Ω 

±

8.0%rdg

±

4dgt 

Cont. 

0.0

-

419.9

Ω 

Bz threshold value 

50

±

30

Ω 

 
Open-loop voltage 

<3.4V (400

Ω / Cont Range) 

  :

0.7V typ (4k

Ω Range) 

0.47V typ (40k 

40M

Ω Range) 

 

Input protective voltage 

AC/DC600V / 10 sec 

 

Measuring method    2 Dual integration 

 

Over-range indication    OL 

 

Measurement cycle / 2.5 times per second 

  0       

Applicable Standards 

    IEC/EN 61010-1/ 61010-2-032/ 61010-031       
    /61010-2-030 
    2 / Pollution degree 2 

Indoor use 
Altitude up to 2000m 
Current measurement section CAT.III 600V 
Voltage measurement section   
CAT.II 600V / CAT.III 300V 

 

EN61326 (EMC) 

    RF 3V/m 5 
    In the radio-frequency electromagnetic field of         
    3V/m, accuracy is within five times the rated       
    accuracy. 
 

Withstand voltage 

    AC5320Vrms 5 

AC3540Vrms 5 
AC5320Vrms 5sec between current sensor and         
enclosure 

    AC3540Vrms 5sec between circuit and enclosure 
 

Insulation resistance >100M

Ω / 

between enclosure and electrical circuit 
 

0

40°C 85% 

Operating Temperature and humidity range 
0 to

 

40°C 85%RH or less (no condensation) 

 

-20

60°C 85% 

Storage Temperature and humidity range 
-20 to 60°C 85%RH or less (no condensation) 
 

Power source 

    DC3V

4

×

2 / R03/LR03 (AAA) 

×

 

Current consumption < 3mA 

 

Battery life 350 (ACA / Approx. 350 hours (ACA,         

    continuous, no load) 
 

Dimension, Weight 190(L)

×

68(W)

×

20(D)mm 

    approx. 120g / including batteries

 

 

Accessories 
Test leads Model 7107A 

1set 

    Battery R03(AAA) 

2pcs 

    Instruction manual 

1pce 

Carrying case Model 9160 

1pce 

 
 

2. Other Function 

 

Data Hold 

    Press the Data Hold Key to freeze the reading. 

Press the Data Hold Key again to release the   
freezing display. 

 

 
 

         

  LCD 

         

  / indicated 

“      ” on LCD 

 

 

Low battery indication 

 

2.3

±

0.15V LCD 

“      ”   

indicated 

“      ” on LCD at 2.3

±

0.15V or less 

 

Sleep Function

 

10

ON LCD "            " 2 

 
Automatically powered off in about 10min after. 
To disable the sleep function, power the   
instrument on with the Data Hold Key pressed. 

(indicated "            " for about 2 seconds on LCD) 

 

3. ACA / Measurement 

 

DANGER

 

Never  measure  current  while  the  test  leads  are 
inserted into the V/

Ω and/or COM Terminals.

 

 
 

Function Switch

 

Current Sensor

 

 
Mode Key 

 
Data Hold Key

 

LCD

 

V/

Ω Terminal

 

COM Terminal

 

 
Trigger

 

Snap Band

 

Cap 

 

Barrier of Test Leads 

 

Barrier

 

 

 

WARNING 

Read through and understand the 
instructions contained in this manual 
before using the instrument.

 

Отзывы: