Major tech MTD70T Скачать руководство пользователя страница 5

5

2.1. Meter Descriptions

1  - NCV Test 
2  - Current clamp 
3  - LED Flashlight 
4  - Non-contact AC voltage indicator light 
5  - Clamp trigger 
6  - Rotary Function switch 
7  - SELECTOR mode range button 
8  - Data Hold button 
9  -    REL button for Relative Measurement 
10 - Flashlight and LCD backlight button  
11 - LCD display 
12 - COM input jack 
13 - V 

Ω

 Diode Continuity CAP TEMP Hz% jack 

14 - Battery Cover 

2. Descriptions

2

5

7

1

9

11

12

3

4

6
8
10

13
14

Button

Operation Performed

 

HOLD 

Data Hold

Minus sign  

Negative reading display 

0 to 3999  

Measurement display digits 

NCV  

Non-Contact Voltage  

AUTO  

Auto Range mode 

DC  

Direct Voltage 

AC  

Alternating Current/Voltage 

 

Low battery 

mV or V  

Milli-volts or Volts (Voltage) 

Ω 

 

Ohms (Resistance) 

A  

Amperes (Current) 

F  

Farad (Capacitance)

Hz/%  

Hertz (Frequency)/Percent(duty ratio) 

°C  

Celsius units (Temperature) 

n, m, 

μ

, M, k  

Unit of measure prefixes: nano, milli, micro, mega, and 

kilo 

 

Continuity test 

 

Diode test 

2.2. Display Icons

Содержание MTD70T

Страница 1: ...MTD70T 600A AC TRUE RMS DIGITAL CLAMP METER INSTRUCTION MANUAL...

Страница 2: ...2...

Страница 3: ...ue RMS 7 4 3 DC Voltage 7 4 4 Resistance 7 4 5 Diode and Continuity 8 5 Operation 8 5 1 AC Current Measurements 8 5 2 AC Voltage Measurements 9 5 3 DC Voltage Measurements 9 5 4 Resistance Measurement...

Страница 4: ...he circuit under test 1 4 Cautions Improper use of this meter can cause damage shock injury or death Read and understand this user manual before operating the meter Always remove the test leads before...

Страница 5: ...Battery Cover 2 Descriptions 2 5 7 1 9 11 12 3 4 6 8 10 13 14 Button Operation Performed HOLD Data Hold Minus sign Negative reading display 0 to 3999 Measurement display digits NCV Non Contact Voltag...

Страница 6: ...ge Humidity 80 Operating Altitude 2000meters 7000ft maximum Battery 2 x 1 5V AAA Battery Battery life Approx 30h backlight ON Approx 100h backlight OFF Auto power OFF After approx 15 minutes Dimension...

Страница 7: ...ion 4 3 DC Voltage Accuracy of reading digits Input impedance on 200mV range 40M all other ranges 10M Overload protection 600V DC or RMS of AC Input Protection 250V DC or Peak value of AC Note a On 20...

Страница 8: ...20A for low current readings 3 Press the trigger to open jaw Fully enclose only one conductor For optimum results center the conductor in the jaw 4 The clamp meter LCD will display the reading NOTES...

Страница 9: ...2 Set the function switch to the position 3 Use SELECT Button to select The display icons will change when the SELECT button is pressed 4 Touch the Test Probe tips across the circuit or component unde...

Страница 10: ...ly lit areas Press the button for 3 seconds to turn the Flashlight and LCD backlight on Press once again to turn the Flashlight and backlight off The both work simultaneously 5 10 Range Function Press...

Страница 11: ...the meter from any circuit remove the test leads from the input terminals and turn OFF the meter before opening the case Do not operate the meter with an open case 6 2 Battery Replacement 1 When the...

Страница 12: ...www major tech com www majortech com au sales major tech com info majortech com au MAJOR TECH PTY LTD South Africa Australia...

Отзывы: