background image

 

Introduction 

The Refrigerant Leak Detector detects all CFC refrigerants 

such as R-22, R-124, R-11 and R-12. The ultra-sensitive 

long-life sensor detects the more current, difficult to detect 

HFC refrigerants such as R-134a, R-404A, and new R-22 

replacements, R-410A and R-407C. The Refrigerant Leak 

Detector’s long, slim gooseneck probe design is easy to use 

in close areas and for extending into hard-to-reach areas. It 

is adjustable alarm, easy one-hand operation and impact 

resistance storage case add up to value and convenience 

 

Applications and Features include 

Easily operate the Refrigerant Leak Detector with one hand 

to detect presence of Refrigerants. Audible and visual 

indicators help pinpoint leak source. Adjustable “tic” rate 

helps eliminate background gas concentration in 

contaminated environments.

 

 

high sensitivity to detect.100ppm of R- 134a /R- 22

 

 

Adjustable tick rate to locate leaks quickly and easily

 

 

Visual leak detection by LED indicators

 

 

Precision sensor detects even the smallest leaks

 

 

Includes earphone Jack

 

 

16” gooseneck

 

 

International Symbols 

 

Important Information; see manual 

 

Conforms to European Union directives   

Содержание MT980

Страница 1: ...Instruction Manual MT980 Refrigerant Halogen Leak Detector...

Страница 2: ...mpact resistance storage case add up to value and convenience Applications and Features include Easily operate the Refrigerant Leak Detector with one hand to detect presence of Refrigerants Audible an...

Страница 3: ...frigerant Leak Detector runs through a one minute warm up and self zeroing sequence when it is first turned on in fresh air The alarm of the instrument maybe very loud without detecting any gas That i...

Страница 4: ...or tic through the earphone is very loud If the READY light is off the batteries are low They should be replaced immediately Low batteries will adversely affect the instrument s reliability See the re...

Страница 5: ...he tab at the bottom of the battery cover while lifting it out 3 Remove the batteries using a coin or screwdriver if necessary to pry them out 4 Replace all three batteries with new ones Replacing the...

Страница 6: ...Approx 1 minute Response Time Less than 2 seconds up to 40 LEL Alarm Visible Audible at 10 LEL for all chlorofluorocarbons CFC Power Supply 3 C cell batteries Battery Life 8 hours continuous use typic...

Страница 7: ...C FR 12 R 113 R 13B R 503 ALTERNATIVES R 409A FX 56 Freeze 12 Free Zone GHG X5 GHG HP IKON 12 R 403B R 508A R 508B R 502 R 500 ALTERNATIVES HC REFRIGERANTS not SNAP approved R 402A R 402B R 404A R 407...

Страница 8: ...8...

Отзывы: