13
5.3. AC/DC Current Measurement
WARNING:
Observe all safety precautions when working on live circuits.
Measurements in the 10A range should be limited to 30 seconds maximum
every 15 minutes.
1. Insert the black test lead banana plug into the
COM
Input Jack.
2. For current measurements up to
10A
AC/DC, set the rotary function
switch to the
10A
Position and Insert the red test lead into the
10A
Input
Jack.
3. For current measurements up to
400mA
AC/DC, set the rotary function
switch to the
mA
Position and
Insert the red test lead into the
Positive
Input Jack.
4. For current measurements up to
4000μA
AC/DC, set the rotary function
switch to the
μA
Position and
Insert the red test lead into the
Positive
Input Jack.
5. Press the
MODE
Button to select AC or DC current, the
AC
“ ” or
DC
“ ” symbol will be shown on the LCD display.
6. Remove power from the circuit under test, then open up the circuit at the
point where you wish to measure current.
7. Touch the black test probe tip to the neutral side of the circuit; Touch the
red test probe tip to the “hot” side of the circuit.
8. Apply power to the circuit, Read the current on the LCD display.