background image

WARNING:

 Disconnect the test leads from any source of voltage

before removing the back cover or the battery/fuse door. Do not operate
your meter until the rear housing is in place and fastened
securely.

10

4.8. Iceo (LEAKAGE CURRENT) TEST

1. Insert the test leads into COM (Black lead) and "+" socket (Red lead).
2. Set the function switch to X10 (15mA) for small size transistor, or to X1 

(150mA) for big size transistor.

3. Short the test leads and turn on adjusting knob to set the pointer to 

the zero position.

4. Making Measurement:

A. For NPN transistor, the "N" terminal of the tester is connected to the 

COLLECTOR (C) of the transistor, the "P" terminal is connected to the 
EMITTER (E) of the transistor.

B. For PNP transistor, reverse the connection of NPN transistor connect.

5. For the lceo range, if the pointer is not within the LEAK zone or the 

pointer moves up near to the full scale, it means that the transistor is 
not good. Otherwise, it is a good transistor.

4.9. hFE (DC AMPLIFICATION) TEST

1. Insert the test leads into COM (Black lead) and "+" socket (Red lead).
2. Set the function switch to X10.
3. Short the test leads and turn on 0

Ω

 adjusting knob to set the pointer to 

zero position.

4. Making Measurement:

A. For NPN FE transistor.                                                                 

ii. Plug the hFE connector into "N" terminal and connect its red clip 
to the collector and the black one to the base of the transistor.

B. For the PNP transistor,                                                                 

i. Connect the "N" terminal of the tester to the emitter of the 
transistor.                                                                                    
ii. Plug the hFE connector into the "P" terminal and connect the clips 
in the same way as NPN transistor connection.

5. Read the hFE scale. The value of the reading is lc/lb, which is the DC 

amplication degree of the transistor.

5. BATTERY REPLACEMENT

1. Take out the plastic protection cover first
2. Remove Philips head screw and lift off the rear housing of the meter.
3. Replace old battery with fresh 9V and AA type battery.
4. Replace the rear cover and secure the screw.

Содержание MT832

Страница 1: ...INSTRUCTION MANUAL ANALOGUE MULTIMETER MT832...

Страница 2: ...2...

Страница 3: ...Specifications 6 3 Meter Description 7 4 Operation 7 4 1 Resistance Test 8 4 2 Continuity Test Buzz and LED 8 4 3 DCV Test 8 4 4 ACV Test 9 4 5 Decibel 9 4 6 DCA Test 9 4 7 ACV Test on Output Termina...

Страница 4: ...tance test Transistor test and hFE test 1 READ and UNDERSTAND all of the instructions and safety information in this manual before operating or servicing this instrument 2 Keep this instruction manual...

Страница 5: ...l lceo hFE B 10 B 50 B 250 B 10 B 50 B 250 B 10 C 10 B 50 B 250 B 10 B 50 B 250 B 250 B 250 A A A A A G G G E E D Test Range Position Scale to Read Multiplyer x0 01 x0 01 x0 01 x1 x1 x1 x100 x1 x1 x1...

Страница 6: ...5mA 0 25A x1 0 2 up to 2k Mid scale at 20 x10 2 up to 20k Mid scale at 200 x100 20 up to 200k Mid scale at 2k x1k 200 up to 2M Mid scale at 20k x10k 2k up to 20M Mid scale at 200k 150 A 1 5mA 15mA 150...

Страница 7: ...erminal COM COMMON 8 Measuring Terminal 9 Plastic Protection Cover 3 METER DESCRIPTION 4 OPERATION WARNING 1 Before using this instrument please adjust the ZERO by Zero Corrector 2 When measuring the...

Страница 8: ...cket Red lead 2 Set the range function switch to BZ CONT Y position apply the test lead pins to two points to be tested While tested circuit is continuous it should indicate to you as below A Buzz and...

Страница 9: ...from the circuit under test then open up the circuit at the point where you wish to measure current Fig 04 4 Read the DCV A scale converted with the reference table Reset the function switch to succe...

Страница 10: ...the full scale it means that the transistor is not good Otherwise it is a good transistor 4 9 hFE DC AMPLIFICATION TEST 1 Insert the test leads into COM Black lead and socket Red lead 2 Set the functi...

Страница 11: ......

Страница 12: ...www major tech com www majortech com au sales major tech com info majortech com au MAJOR TECH PTY LTD South Africa Australia...

Отзывы: