Major tech MT760 Скачать руководство пользователя страница 12

the circuit-under-test is conductive (

10Ω), buzzer makes sound 

continuously. When measure voltage or current outrange, buzzer will 
"Beep" to warn outrange, function status is as below:

 

a) When AC, DC voltage

 <

600V, buzzer beeps

 

b) 100A AC and DC gear: current >maximum range, buzzer beeps.

•   Low-voltage detect: when battery voltage is lower than 2.5V, battery 

under-voltage symbol if       appears, measurement accuracy may be 
lower once this symbol shows, replace battery timely; if it is lower 
than 2.2V, only battery under-voltage symbol shows after starting up, 
it can't work.

•   When battery supply voltage lowers to 2.6V, LCD backlight will be in 

weak or non-start state; but measurement functions still work.

12. Technical index

Accuracy: ±(a% b word count), warranty period is 1 year.
Environment temperature: 23°C ±5°C (73.4°F ±9°F) relative humidity

     

 75%

     Input resistance is about 10MΩ. (as input resistance is high, when

200mV range open circuit, there may be instable digital display,
but measurement can be stabilized once the measured source with
internal resistance lower than 10MΩ is connected, but the impact
of internal resistance of measured source on measurement reading
should be considered)
Maximum input voltage: ±600V

Resolution

200.0mV  

0.1mV  

±(0.7%+5)

2.000V  

1mV

20.00V  

10mV 

±(0.7%+3)

200.0V  

100mV

600V  

1V

Range

1. DC Voltage Measurements

Accuracy

Resolution

2.000V  

1mV 

± (1.0%+3)

20.00V  

10mV

200.0V  

100mV 

±(1.0%+3)  V.F.C. mode:± (4.0%+3)

600V  

1V 

±(1.2%+3)  V.F.C. mode:± (4.0%+3)

Range

2. AC voltage measurement

Accuracy

12

Содержание MT760

Страница 1: ...MT760 100A AC DC TRMS MINI CLAMP METER INSTRUCTION MANUAL II...

Страница 2: ...2...

Страница 3: ...tions 4 4 Electrical Symbol 5 5 General Standard 6 6 Product Panel Figure 7 7 LCD Full View Figure 8 8 Operation Instructions 9 9 AC DC Current Measurement 10 10 NCV Non contact Field Measurement 11 1...

Страница 4: ...II 600V CAT III 300V and Double Insulation standards Conforms to UL STD 61010 1 61010 2 032 61010 2 033 Certified to CSA STD C22 2 NO 61010 1 IEC STD 61010 2 032 6101 0 2 033 CAT II Applicable to test...

Страница 5: ...k 10 Probe assemblies used for MAINS measurements CAT II 600V CAT III 300V according to IEC 61010 031 If you want to replace the probe assemblies and they need the same level CAT II 600V CAT III 300V...

Страница 6: ...approx 175 x 60 x 33 5mm maximum clamp head size is 17mm 9 Weight approx 170g including battery 6 Product panel figure 1 Clamp head 2 Protective barrier 3 Clamp head trigger pull the trigger to open...

Страница 7: ...tance on off capacitance diode red meter pen inserts into this jack 11 lnput jack at COM terminal when measure voltage resistance on off capacitance diode black meter pen inserts into this jack 12 lnd...

Страница 8: ...ative reading Diode measurement prompt Circuit on off measurement prompt Data hold prompt Resistance unit 0 kO MO Frequency unit Hz kHz MHz Voltage unit mV V Current unit mA A Capacitance unit nF F mF...

Страница 9: ...sure voltage maximum input voltage is 600V AC DC do not exceed this limitation otherwise it may cause electric shock or damage to the meter 2 Resistance circuit on off diode capacitance Insert red met...

Страница 10: ...several times until the reading is zero Note as the product is highly sensitive to ensure correct measurement data direction of meter during measurement should be the same as when it is in zero as muc...

Страница 11: ...easuring if the rotary button has not been moved for 15 minutes the instrument will automatically power off to save energy In automatic power off mode turn rotary button to OFF and restart the machine...

Страница 12: ...tart state but measurement functions still work 12 Technical index Accuracy a reading b word count warranty period is 1 year Environment temperature 23 C 5 C 73 4 F 9 F relative humidity 75 Input resi...

Страница 13: ...value measurement display value meter pen short circuit value Open circuit voltage is about 1V Overload protection 600V RMS Resolution Resistance value for circuit disconnect 150 buzzer makes no soun...

Страница 14: ...ion of meter during measurement should be the same as when it is in zero as much as possible Resolution 2 000A 1mA 3 10 V F C mode 4 0 10 20 00A 10mA 2 5 8 V F C mode 4 0 10 100 0A 100mA 2 5 5 V F C m...

Страница 15: ...qualified professional serviceman or designated maintenance department 2 Replace battery see Figure 8 When LCD displays under voltage a prompt replace built in battery immediately otherwise it will af...

Страница 16: ...www major tech com www majortech com au sales major tech com info majortech com au MAJOR TECH PTY LTD South Africa Australia...

Отзывы: