INRUSH Button

INRUSH current measurement function, is in the manual measurement mode. The 
need for the operator to predict the value of the inrush current and then select 
the appropriate measuring range, to ensure the accuracy of the measurement.

Ÿ

 Press the "

INRUSH

" key to enter "

INRUSH

" measurement mode, LCD screen 

displays "----", at this time the instrument is preset in the 3000A range. 

Ÿ

 After entering the 

INRUSH

 measurement mode, hold down the "

INRUSH

key, it will then convert to a 30A measurement range; hold down again, it will 
then convert to a 300A measurement range; hold down again, it will then 
convert to 3000A measurement range.

Ÿ

 The preset range, starting with electrical equipment, inrush current value will 

remain on the LCD screen. If you want to measure again, you need to re-enter 
the measurement model.

Ÿ

 Enter the "INRUSH" mode, and then press the "

INRUSH

" key, you can exit 

the measurement model.

Press the 

LOG

 key, the meter will display    and will begin to record the current 

changes in the known period of time data, and store it on the meter for the 
Mobile APP to read and analyze. Hold down the    key to enter Bluetooth mode, 
the meter will display   , the data will be sent to the Mobile APP in immediately. 
With Bluetooth active, hold down the 

LOG

 key, the meter will display "

SEND

", 

you can send the data stored in the data to the Mobile APP, select send the 
complete automatic return to the measurement mode.

Note: Bluetooth Connect:

1.  Turn on the Bluetooth function on the instrument using Menu Button
2.  Turn on the Bluetooth of the Smartphone, press the 

Meterbox Pro

 icon and 

enter into the home interface. Then press 

Connect Device

 icon on the home 

interface, Bluetooth device name will appear.

3.  Touch the device name listed in Bluetooth devices list to connect the meter.

Meterbox Pro for Android & iOS: 

 Please search in the app stores with 

keyword Meterbox Pro, download and run.

LOG Button

Ÿ

  Remove the Phillips head screw that secures the rear battery door.

Ÿ

  Open the battery compartment and replace the two 1.5V AAA batteries.

Ÿ

  Secure the battery compartment.

Maintenance

Cleaning and Storage

Wipe the case with a damp cloth and mild detergent; do not use abrasives or 
solvents. If the meter is not going to be used for more than 60 days, remove 
the battery.

Battery Replacement