7
Range
Resolution Accuracy
6.000V
1mV
+1.2% of rdg + 3 dgts
60.00V
10mV
+1.5% of rdg + 3 dgts
600.0V
100mV
1000V
1V
+2.0% of rdg + 4 dgts
5.2. AC VOLTAGE
Input Impedance: 7.8M
Ω
.
Frequency Range: 50 to 60Hz
Maximum Input: 1000V DC or 1000V AC RMS.
Range
Resolution Accuracy
6A
1mA
+2.5% of rdg + 5 dgts
10A
10mA
5.3. DC CURRENT
Overload Protection: 10A / 250V Fuse.
Maximum Input: 10A DC or AC RMS on 10A DC range.
Range
Resolution Accuracy
6A
1mA
+3.0% of rdg + 5 dgts
10A
10mA
5.4. AC CURRENT
Overload Protection: 10A / 250V Fuse.
Frequency Range: 50 to 60Hz
Maximum Input: 10A DC or AC RMS on 10A AC range.
Range
Resolution Accuracy
600.0
Ω
0.1
Ω
+1.2% of rdg + 4 dgts
6.000k
Ω
1
Ω
+1.0% of rdg + 2 dgts
60.00k
Ω
10
Ω
+1.2% of rdg + 2 dgts
600.0k
Ω
100
Ω
6.000M
Ω
1k
Ω
+2.0% of rdg + 2 dgts
60.00M
Ω
10k
Ω
+5.0% of rdg + 10 dgts
5.5. RESISTANCE
Maximum Input: 600V DC or 600V AC RMS.