Major tech MT22 Скачать руководство пользователя страница 4

4

1. SAFETY INFORMATION

The following safety information must be observed to insure maximum 
personal safety during the operation at this meter:

 

Ÿ

Do not use the meter if the meter or test leads look damaged, or if you 

suspect that the meter is not operating properly.

 

Ÿ

Never earth yourself when taking electrical measurements. Do not 

touch exposed metal pipes, outlets, fixtures, etc., which might be at 
earth potential. Keep your body isolated from earth by using dry 
clothing, rubber shoes, rubber mats, or any approved insulating 
material.

 

Ÿ

Turn off power to the circuit under test before cutting, unsoldering, or 

breaking the circuit. Small amounts of current can be dangerous.

 

Ÿ

Use caution when working above 60V DC or 30V AC RMS. Such 

voltages pose a shock hazard.

 

Ÿ

When using the probes, keep your fingers behind the finger guards on 

the probes.

 

Ÿ

Measuring voltage which exceeds the limits of the multimeter may 

damage the meter and expose the operator to a shock hazard. Always 
recognise the meter voltage limits as stated on the front of the meter.

 

Ÿ

Never apply voltage or current to the meter that exceeds the specified 

maximum:

This symbol adjacent to another symbol, terminal or 
operating device indicates that the operator must refer to an 
explanation in the Operating Instructions to avoid personal 
injury or damage to the meter.
This WARNING symbol indicates a potentially hazardous 
situation, which if not avoided, could result in death or 
serious injury.
This CAUTION symbol indicates a potentially hazardous 
situation, which if not avoided, may result damage to the 
product.
This symbol advises the user that the terminal(s) so marked 
must not be connected to a circuit point at which the voltage 
with respect to earth ground exceeds (in this case) 500 VAC 
or VDC.
This symbol adjacent to one or more terminals identifies 
them as being associated with ranges that may, in normal 
use, be subjected to particularly hazardous voltages. For 
maximum safety, the meter and its test leads should not be 
handled when these terminals are energized.

 

 

MAX  
500V

 

 

2. SAFETY SYMBOLS

Содержание MT22

Страница 1: ...INSTRUCTION MANUAL 1000V AC DC MULTIMETER MT22...

Страница 2: ...2...

Страница 3: ...AC Current 8 5 7 Resistance Auto Ranging 9 5 8 Temperature 9 5 9 Diode Test 9 6 Operation 9 6 1 Mode Button 10 6 2 Range Button 10 6 3 Data Hold Button 10 6 4 Max Hold Button 10 6 5 DC Voltage Measur...

Страница 4: ...the operator to a shock hazard Always recognise the meter voltage limits as stated on the front of the meter Never apply voltage or current to the meter that exceeds the specified maximum This symbol...

Страница 5: ...10A DC or AC measurements 6 Mode push button selection Continuity Diode AC DC Temperature C F 7 Range push button 8 Data Hold push button 9 MAX Hold push button Input Limits Function Maximum Input V D...

Страница 6: ...es per second nominal Auto power off Meter automatically shuts down after approx 15 minutes of inactivity Operating environment 0 C to 50 C 32 F to 122 F at 70 relative humidity Storage temperature 20...

Страница 7: ...20 00V 10mV 1 5 of rdg 3 dgts 200 0V 100mV 600V CAT III 1V 2 0 of rdg 4 dgts 1000V CAT II 2 0 of rdg 8 dgts 5 2 AC Voltage Auto ranging except 200mV Input Impedance 10M Frequency Range 50 to 60Hz Max...

Страница 8: ...1 0 of rdg 3dgts 2000A 1A meter only Clamp on Adaptor accuracy not included 5 5 Clamp on Adaptors DC Current Sensor Clamp on Adaptor Note not provided 200A Range Input Sensitivity 1mV A 2000A Range I...

Страница 9: ...racy 200 0 0 1 1 2 of rdg 4 dgts 2 000k 1 1 0 of rdg 2 dgts 20 00k 10 200 0k 100 1 2 of rdg 2 dgts 2 000M 1k 20 00M 10k 2 0 of rdg 3 dgts 5 7 Resistance Auto ranging Input Protection 500V DC or 500V A...

Страница 10: ...D BUTTON The Data Hold function allows the meter to freeze a measurement for later reference 1 Press the DATA HOLD button to freeze the reading on the indicator The indicator HOLD will be appear in th...

Страница 11: ...sert the black test lead banana plug into the negative COM jack 2 For current measurements up to 2000 A DC set the function switch to the A position and insert the red test lead banana plug into the A...

Страница 12: ...e positive side of the circuit 8 Apply power to the circuit 9 Read the current in the display The display will indicate the proper decimal point value and symbol 6 8 AC CURRENT MEASUREMENTS CAUTION Do...

Страница 13: ...jack and the red test lead banana plug into the positive jack 3 Touch the test probe tips across the circuit or part under test It is best to disconnect one side of the part under test so the rest of...

Страница 14: ...urement 1 When the batteries become drained or drop below the operating voltage BAT will appear in the right hand side of the LCD display The battery should be replaced 2 Follow instructions for insta...

Страница 15: ...r 3 Remove the old fuse from its holder by gently pulling it out 3 Install the new fuse into the holder 4 Always use a fuse of the proper size and value 10A 250V fast blow for the 10A range 1 Put the...

Страница 16: ...www major tech com www majortech com au sales major tech com info majortech com au MAJOR TECH PTY LTD South Africa Australia...

Отзывы: