8. SPECIFICATIONS
Range
Resolution Accuracy
600.0mV 0.1mV
±0.5% of reading ± 5 digits
6.000V
0.001V
60.00V
0.01V
600.0V
0.1V
1000V
1V
±0.6% of reading ± 6 digits
8.1. DC VOLTAGE
Input Impedance: ±10MΩ.
Maximum Input: 1000V DC or 1000V AC RMS.
Range
Resolution Accuracy
6.000V
0.001V
±0.8% of reading ± 4 digits
60.00V
0.01V
600.0V
0.1V
1000V
1V
±0.8% of reading ± 8 digits
8.2. AC VOLTAGE (AUTO-RANGING)
All AC voltage ranges are specified from 5% of range to 100% of range
Input Impedance: ±10MΩ.
AC Response: 50 Hz to 400Hz
Maximum Input: 1000V DC or 1000V AC RMS.
Range
Resolution
Accuracy
50.0V to 600.0V 0.1V
±4.0% of reading ± 9 digits
8.3. AC VOLTAGE (VFD)
Input Impedance: ±10MΩ.
AC Response: 50 Hz to 400Hz
Maximum Input: 600V DC or 600V AC RMS.