Battery life (ACA, continuous, no load, with R03) 

 

: approx. 170 hours

● 

Dimension, Weight : 204(L)×81(W)×36(D)mm, approx. 220g 

 

(including batteries) 

● 

Accessories :

 

Test leads Model 7066A 

1set  

 

Battery R03(AAA) 

2pcs 

 

Instruction manual 

1pce 

 

Carrying case Model 9079 

1pce

3. ACA Measurement

● 

Disconnect the test leads from the instrument when performing a 

 

test.

● 

Do not exceed the rated voltage (600V) and the category ratings 

 

of the instrument.

● 

Keep your fingers and hands behind the barrier during 

 

measurement.

DANGER

(1)    Set the Function switch to AC A position.
(2)    Press the trigger to open the Current Sensor and clamp the 
 

  one conductor (Dia. 33mm max.) under test.

Measurement accuracy is guaranteed when the measured object is 
placed at the center of the Current Sensor.

NOTE

4. ACV/DCV Measurement

(1) Set the Function switch to AC V or DC V position.
(2) Firmly connect the test leads to V/Ω and COM terminals.

ACV

DCV

If the connection is reversed, the LCD indicates the “ 

 “ mark 

(DCV measurement).

NOTE

● 

Before starting a measurement, ensure that the Function switch is 

 

set to the appropriate position.

● 

Do not exceed the rated voltage (600V) and the category ratings 

 

of the instrument.

● 

Keep your fingers and hands behind the barrier during 

 

measurement.

DANGER

Power off the circuit under test before making measurements with this 
instrument.

WARNING

5. Resistance(Continuity)Measurement

(1) Set the Function switch to resistance or continuity position.
(2) Firmly connect the test leads to V/Ω and COM terminals.

Resistance

Continuity

Beeps less than 90Ω

LCD indicates “OL” when the test leads are open.

NOTE

6. Other Functions

● 

Data Hold

 

Press the Hold key. The LCD shows “      ” mark and the reading   

 

will be held.

 

Press the Data Hold Key again 

 

to release the display.

● 

Low battery indication

 

The LCD shows “         ” mark when the batteries fall below the 

 

normal operating voltage.

 

 

 Replace the batteries 

 

 

with new ones when 

 

 

this mark appears.

● 

Sleep Function

 

Automatically powers off the instrument in about 10 min after the  

 

last switch or key operation. Buzzer beeps five times one minute 

 

before entering into the Sleep mode, and also one time just 

 

before entering into the mode. To exit from the Sleep mode, 

 

rotate the Function switch or press Hold key.

 

To disable the Sleep function, 

 

press the HOLD key and 

 

power on the instrument. 

 

Confirm that the LCD shows 

 

” about 1 sec. 

HOLD

H

BATT

H

BATT

7. Battery Replacement

WARNING

●   Do not mix old and new batteries. Brand and type of the batteries 
 

to be used should be harmonized.

●   Install batteries in correct polarity as indicated in the Battery 
 

Compartment.

CAUTION

(1)   Set the Function Switch to "OFF" position.
(2)  Unscrew and remove the Battery Compartment Cover on the 
 

instrument.

(3)  Replace the batteries observing correct polarity. Use new two AAA 
 

1.5V batteries.

(4)  Install the Battery Compartment Cover and tighten the screw.

●   Replace the batteries when a Low Battery Voltage warning "       "  
 

mark is indicated on the LCD. Otherwise, precise measurement 

 

cannot be made.

 

If batteries are completely exhausted, the LCD goes blank without 

 

showing "       " mark.

●   Do not try to replace the batteries if the surface of the instrument 
 

is wet.

●   Disconnect the test leads from the object under test and power 
 

off the instrument before opening the Battery Compartment 

 

Cover for battery replacement.

BATT

BATT

MAJOR TECH

(PTY) LTD

T9 Industrial Village,  Sam Green Road, 

Tunney Ext. 9,

 Elandsfontein

South Africa
P.O. Box 888, Isando 1600, 
South Africa

Telephone: +27 11 8 2 

7 5500

National Contact Number: 08 61 62 5678
Sales Facsimile: +27 11 822 2806

 

Admin Facsimile: +27 11 822 1411
E-mail: [email protected]

www.major-tech.com

Отзывы: