background image

 

 

15 

Operation stops with 

alarm: 

Display shows 

 

Over Voltage 

 

- Verify that the running buffer is correct. 

- Verify the all cables are attached correctly 

-  Turn  the  Power  switch  off  and  on  again; 

restart application. 

- If you cannot restart the instrument, turn off 

the  power,  disconnect  the  power  cord  from 

the outlet, and contact Technical Service.

 

Operation stops with 

alarm: 

Display shows 

 

Ground leak detected 

during run

 

Check the electrophoresis system for 

improper grounding. Restart the power supply 

by turning the Power switch off and on. 

Operation stops with 

alarm: 

Display shows 

 

 

Power supply is 

overheating 

 

- Turn off power supply. Check for sufficient 

airflow around the power supply fan. After 

cooling down, restart the power supply by 

turning the Power switch to the on position. 

- If you cannot restart the instrument, turn off 

the power, disconnect the power cord from  

the outlet, and contact Technical Service.

 

Operation stops with 

alarm: 

Display shows 

 

Bad connections for 

terminal connectors or 

damaged wires or 

damaged platinum wires 

Check all the connections to terminators, 

cables, wires, and gel tanks 

Operation stops with 

alarm: 

Display shows 

  and 

countdown 

Power supply is getting 

restart ON 

- Verify that the electrophoresis condition and 

system is correct. 

- Pay attention to the own safety. 

 

Encountering Problems 

1. Check the troubleshooting section. 

2. Call Technical Service or e-mail to 

[email protected]

 

3. If the unit must be shipped back for repair, contact Major Science or the 

distributor for a Return Authorization Number and shipping instructions. The  

unit will be repaired as quickly as possible and returned to you. 

 

Содержание MP-250V

Страница 1: ...MS 250V MS 300V Power Supply Instruction Manual Catalog Nos MP 250V MP 300V www majorsci com service majorsci com Version 01A October 20 2009...

Страница 2: ...Cord 1 x MS 250V MS 300V Power Supply Instruction Manual Major Science is liable for all missing or damaged parts accessories within 7 days after customer received this instrument package Please conta...

Страница 3: ...MP 250V or MP 300V 1 x MP 250V or MP 300V 1 x US Plug Power Cord or 1 x Euro Plug Power Cord or 1 x UK Plug Power Cord or 1 x Israel Plug Power Cord 1 x MS 250V MS 300V Power Supply Instruction Manua...

Страница 4: ...ning 4 Safety Information 5 Product Specifications 7 Product Description 8 Introduction Overview Controls and Features 9 9 10 Installation Instructions 11 Operation Instructions 12 Troubleshooting Gui...

Страница 5: ...equipment is operated 1 Read and follow carefully the manual instructions 2 Do not alter the power supply series Failure adhered to these directions could result in personal and or laboratory hazards...

Страница 6: ...emperature Avoiding Electrical Shock Follow the guidelines below to ensure safe operation of the unit MS 250V MS 300V power supply series has been designed to use with shielded wires thus minimizing a...

Страница 7: ...ds other than manufacturer s recommendation users should check with the manufacturer s instruction to confirm if the proposed method will not damage the equipment Equipment Operation Follow the guidel...

Страница 8: ...rs Timer 1 999 mins with alarm continuous Safety Device No Load detection Leakage detection Over temperature protection Over load protection Shrouded plugs and sockets Sudden load change detection Cro...

Страница 9: ...ave bench top space Major Science MS 250V power supply and MS 300V power supply both provide Constant Voltage or Constant Current to instruments used in electrophoresis 4 pairs of terminator and the m...

Страница 10: ...four pairs of terminator compact size RoHS and CE compliance for safety concerns can deliver accurate and reliable experimental results from one experiment to another Both of them are perfectly design...

Страница 11: ...age for the location of the following controls and features MS 250V Power Supply Cat No MP 250V MS 300V Power Supply Cat No MP 300V Front Control Panel 1 Key to increase either Voltage or Current or T...

Страница 12: ...the timer 5 Key to select Voltage value 6 Key to select Current value 7 Key to set or select Timer mode Installation Instructions Major Science MS 250V MS 300V Power Supply series is actually an alrea...

Страница 13: ...the electrophoresis unit insert the red lead into the red output jack and the black lead into the black output jack 5 Press Key and then press Key or Key to select the suitable voltage 6 Press Key an...

Страница 14: ...he LED is flashing Press Key to restart the run 11 Press Key again to stop the unit at any time if necessary 12 When the run is completed operation stops with alarm and the screen shows Press Key to t...

Страница 15: ...ot connected to the power supply or to the electrophoresis unit s or there is a broken circuit in the electrophoresis cell Check the connections to the power supply and on your electrophoresis cell to...

Страница 16: ...e power supply by turning the Power switch to the on position If you cannot restart the instrument turn off the power disconnect the power cord from the outlet and contact Technical Service Operation...

Страница 17: ...inserting a small flat blade screwdriver into the slot below the ON OFF switch Turn the screwdriver to gently pry open the fuse compartment Note The fuse compartment will not open with the power cord...

Страница 18: ...ecalibration under normal use The housing may be cleaned with a dry cloth If the unit must be returned for repair contact our SERVICE DEPARTMENT or your local distributor for shipping instruction Orde...

Страница 19: ...is embraced within the terms of the warranty All claims made under this warranty must be presented to Major Science within two years following the date of delivery of the product to the customer Manuf...

Страница 20: ...19 MEMO...

Отзывы: