Majestic Vermont Castings ODSHR42 Скачать руководство пользователя страница 10

10

ODSHR Series

20002264

4. Positioning, Safety Strips,

Securing the Fireplace

Slide fireplace into position.

Lift the fireplace front slightly and slide the metal safety
strips under front bottom edge about 1

¹⁄₂

 inches,

allowing the remainder to extend in front of firebox.
Overlap strips at least 1/2 inch to provide a positive
joint. (Flat safety strips are packed with fireplace.)
(Fig. 12)

Safety strips are used to ensure that any combustible
materials in front of the fireplace are protected even
though a noncombustible hearth extension is required.

If fireplace is to be elevated above the floor, a “Z”
shaped metal safety strip must be fabricated and used
to protect combustible surfaces in front of the fireplace.
This “Z” shaped safety strip is not provided but must be
fabricated of metal with each horizontal leg at least 1

¹⁄₂

inches wide and equal in length to the metal strips
provided with the fireplace.

Note:  Safety strips are not required over non-combus-
tible floors where all supports at the base of the fire-
place are noncombustible.

Four (4) nailing flanges are supplied with the fireplace
(found on the fireplace hearth). To level the box and
secure it firmly in place, remove the nailing flanges from
the hearth and install at the sides of the fireplace as
shown in Figure 13.

Installing Outside Air Kit

An outside air damper assembly is installed in all

ODSHR Series Fireplaces. If desired, or if local codes
mandate the use of an air kit, then an AK-MST is
required to complete the installation (from air damper
assembly to the outdoors). If the outside air kit is to be
used, the AK-MST MUST be installed BEFORE the
fireplace is enclosed. Refer to the AK-MST instructions
for field installation.

FP549

Fig. 13  Fasten fireplace in position.

Nail Side-
nailing
Flanges

FP557a

Fig. 12  Safety strip installation.

1¹⁄₂

"

Metal Safety Strips
(1, 2 or 3 pieces)

"Z" Safety
Strip

(not supplied)

Hearth Ext.

Plat-
form

Fire-
place

1/2" Min.
Overlap

Содержание Vermont Castings ODSHR42

Страница 1: ...ies Outdoor Woodburning Fireplace Homeowner s Installation Operating Manual DO NOT DISCARD THIS MANUAL Retain for future use 20002264 2 03 Rev 9 Model ODSHR42 2264 Underwriter s Laboratories Report No...

Страница 2: ...party approval of such component parts or accessory Any such action may possibly cause a fire hazard Consult local building codes to ensure that you are in compliance before installing the fireplace...

Страница 3: ...42 52 44 24 7 13 Dia Rough Opening Width 53 Rough Opening Depth 62 62 87 10 26 35 48 44 12 11 Dia 15 13 7 14 Outside Air Gas Line Access Gas Line Access FP546A Fig 1 ODSHR42 Series specifications and...

Страница 4: ...n FP1001 Fig 3 Freestanding installation Chase Installation Insulation methods shown are optional for cold climate not a requirement for unit operation FP554A Fig 2 Fireplace and chase parts identific...

Страница 5: ...e chimney is measured from the hearth to the chimney exit ODSHR42 Maximum 90 Minimum Without Elbows 14 6 With 2 Elbows 15 6 With 4 Elbows 21 0 B Do not use more than 4 elbows per chimney Attach the st...

Страница 6: ...e a fireplace will be set and how the chimney system will be run Mounting the Fireplace A fireplace may only be mounted on the following surfaces 1 A flat combustible surface 2 A raised wooden platfor...

Страница 7: ...for Cold Climates If you live in a cold climate it is not required but highly recommended that you insulate fireplace enclosure to eliminate cold air penetration as much as possible Insulate base of f...

Страница 8: ...ECIFICALLY CHECK THE END CONNECTION OF CHIMNEY SECTIONS AND ELBOWS Note ODSHR Series Fireplaces must use Vermont Castings Majestic Products model 11CF 11 inch 2 wall chimney systems The installation p...

Страница 9: ...spacer model num bers The inside dimension of the frame must be the same as the hole size selected from Figure 10 in order to provide the required 2 inches of air space between the outside diameter of...

Страница 10: ...he metal strips provided with the fireplace Note Safety strips are not required over non combus tible floors where all supports at the base of the fire place are noncombustible Four 4 nailing flanges...

Страница 11: ...ide minimum required air space to chimney pipe for ceiling thickness up to eight 8 inches When combined thickness of ceiling material ceiling joists and flooring material exceeds eight 8 inches adjust...

Страница 12: ...re must be a 2 inch air space between outermost portion of chimney sections and any adjacent combus tible surfaces Combustible surfaces include burnable materials such as ceiling members joists floori...

Страница 13: ...rances to combustibles Air Space Clearances Combustible framing material MUST NOT penetrate AIR SPACE shaded areas Standoff 2 Air Space to Sides Firestop Front View Side View Wall Shield Air Space to...

Страница 14: ...f adding protection to side walls and can be used in place of the SP40 with the same wall clearances specified for the SP40 Rt must 1 85 minimum Examples of wall shield insulation 1 Manville CERAFORM...

Страница 15: ...K thermal conductivity Non combustible material with a lower R value may be used provided thickness of material is sufficiently greater to maintain an equivalent total thermal resis tance Rt Example o...

Страница 16: ...ch at Ledge Brackets Fig 18 Hearth Extension Hearth Extension Insulation Molding used to Fasten Hearth Extension in Place Majestic Safety Strips Must be Overlapped 1 2 Min Seal Crack Between Fireplace...

Страница 17: ...e only when 1 incorporating an automatic shutoff device and 2 complying with the Standard for Decorative Gas Appliances for Installation in Vented Fireplaces ANSI Z21 60 or CSA draft requirements for...

Страница 18: ...8 10 9a b 13 Ref Description Part Number 1 Damper Blade 3990185 2 Damper Handle 20001418 3 Screen Rail 20002262 4 Screen Rod 20002222 5 Screen two per fireplace 20002223 6 Screen Pull two per firepla...

Страница 19: ...for fuel conbustion in the firebox This accessory must be installed before fireplace is installed Located on the floor in front of fireplace to protect the floor from heat hot embers ashes etc Used t...

Страница 20: ...CF30 2 11 30 flue S20BR BT BW S20UB Upper Baffle 20002673 Contact the Vermont Castings Majestic Products with questions concerning prices and policies covering replacement parts Parts may be ordered t...

Страница 21: ...mer of Vermont Castings Majestic Products then current list price FOB Vermont Castings Majestic Products factory or pay to the consumer the then current wholesale price of such defective part This war...

Страница 22: ...DSHR Series 20002264 Vermont Castings Majestic Products 410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 905 670 7777 www majesticproducts com www vermontcastings com Vermont Castings Majestic Prod...

Отзывы: