A. FAQs

If smoke spillage occurs from a fireplace opening when 

the door is open, there is either a leakage in the flue, a 

blockage in the flue, or some condition is affecting draft 

Understanding and differentiating the conditions which 

can cause each of these kinds of spillage problems is 

essential to their solution.

•  Flue Leakage

  Check  for  improperly  connected  flue  joints  or  a 

damaged  flue  joint  in  the  chimney  system.  Such 

leakage would reduce draft (air would be drawn in 

through the leaks rather than through the fireplace). 

The  result  might  be  difficult  start-up  and  smoky 

fires that might spill if other adverse draft conditions 

accompany this problem.

•  Flue Blockage

  The damper should be open.

  Check  for  objects  that  may  have  fallen  down  the 

chimney.

Be sure you have air available for combustion and that 

your firewood is dry and well seasoned. Build your fires 

properly and according to the instructions given in op

-

erating instructions, “Starting a Fire”. Be sure your flue 

system is installed correctly and that it is the proper di

-

ameter and height. Check for the following:

•  All chimney sections are properly installed.

•  The chimney is clean and free of creosote or soot 

buildup.

•  Make sure overhanging trees and branches are cut 

back within ten feet of the top of the chimney and the 

chimney is free of debris from animals.

•  Ensure  the  chimney  cap  is  clean  and  free  of  any 

buildup of soot or creosote if cap is equipped with a 

spark arrestor screen.

•  The wood being used in dry and well seasoned.

If you still suspect you have a low draft problem it may 

be  necessary  to  increase  the  volume  of  air  in  your 

flue system. Since the diameter of your flue system is 

matched with the size of the flue collar and should not 

be changed, then the height of the system must be in

-

creased. Add chimney sections one at a time until the 

draft improves.
In some cases, regardless of what you do, it can still be 

difficult to establish the proper flue draft. This is espe

-

cially evident when using an exterior factory-built chim

-

ney or exterior masonry chimney. Try holding a burning 

rolled up newspaper as close to the flue outlet as pos

-

sible for a few minutes, then light the paper under the 

kindling. The heat generated from the burning rolled up 

newspaper should help get the draft established. 
Still other factors can affect how well your flue system 

performs. Neighboring structures, high winds, tall trees, 

even hillsides can affect air currents around the chim

-

ney. Well designed chimney caps are available that can 

help. Your  fireplace  dealer  is  the  local  expert  in  your 

area.  He  can  usually  make  suggestions  or  discover 

problems  that  can  be  easily  corrected  allowing  your 

fireplace to operate correctly as it has been designed, 

providing safe and economical heat for your home.

Flue  draft  is  measured  as  negative  pressure  in  the 

chimney. The amount of negative pressure determines 

how strong the draft is. The draft is important because 

it draws the combustion air into the fireplace and pulls 

the smoke out of the chimney. 
There are three basic criteria essential in establishing 

and maintaining flue draft:

•  availability of combustion air

•  heat generated from the fire

•  diameter and height of the flue system

These three factors work together as a system to create 

the flue draft. Increasing or decreasing any one of them 

will affect the other two and thus change the amount of 

draft in the entire system.
If the fire is hard to start and smoke spills out of the fire

-

place, or you find it difficult to establish and maintain a 

moderately high burn rate, then the flue draft is too low 

and corrective measures must be taken. 

Hearth & Home Technologies assumes no responsibil

-

ity for the improper performance of the fireplace sys

-

tem caused by inadequate draft due to environmental 

conditions,  down  drafts,  tight  sealing  construction  of 

the structure, or mechanical exhausting devices which 

will create a negative air pressure within the structure 

where the fireplace is located.

Contact your dealer for additional informa-

tion regarding operation and troubleshoot-

ing. Visit www.majesticproducts.com to 

find a dealer.

Majestic Sovereign Series • SA36R/SA42R Owners Manual • 4010-260 • Rev H • 1/2020

Содержание SA36R

Страница 1: ...operation AND cool down Hot glass will cause burns DO NOT touch glass until it is cooled NEVER allow children to touch glass Keep children away CAREFULLY SUPERVISE children in same room as fireplace A...

Страница 2: ...Operating Information A Fireplace Safety 7 1 Clear Space 7 2 Grate 8 3 Refractory 8 4 Firescreen 8 5 Flue Damper 8 6 Glass Doors 8 7 Over Firing Your Fireplace 8 8 Chimney Fire 8 B General Operating...

Страница 3: ...lected is designed to provide the utmost in safety and reliability As the owner of a new fireplace you ll want to read and carefully follow all of the instructions contained in this Owner s Manual Pay...

Страница 4: ...than 24 months following the date of product shipment from HHT regardless of the installa on or occupancy date The warranty period for parts and labor for covered components is produced in the follow...

Страница 5: ...opera on with damaged corroded or failed components accident or improperly incorrectly performed repairs 5 environmental condi ons inadequate ven la on nega ve pressure or dra ing caused by ghtly seal...

Страница 6: ...ion in manufactured homes If installed with a gas log set provisions for the National Fuel Gas Code must be met This fireplace has been tested and listed for use with the optional components specified...

Страница 7: ...adjustment alteration service or maintenance can cause injury or property damage 1 Clear Space Combustible materials must not be stored on the hearth extension Room furnishings such as drapes curtain...

Страница 8: ...grate or one approved by HHT WARNING Risk of Fire Use only the factory sup plied integral grate Keeps logs in place Allows proper air circulation around the fire 3 Refractory The refractory is suppli...

Страница 9: ...adults to hazards of high temperatures High temperatures may ignite clothing or other flammable materials Keep clothing furniture draperies and other flammable materials away HOT SURFACES Glass and ot...

Страница 10: ...LY OPEN INCORRECT FULLY CLOSED CORRECT Figure 3 3 Operating Positions of Bi fold Doors Refer to Figure 3 2 for location and operation of control The outside air kit supplies some combustion air for yo...

Страница 11: ...use the softwood for starting the fire giv ing off quick heat to bring the fireplace up to operating temperature Add the hardwood for slow even heat and longer burn time 2 Moisture content The majori...

Страница 12: ...time it takes to season wood varies from around nine months for soft woods to as long as eighteen months for hardwoods The key to seasoning wood is to be sure it has been split exposing the wet interi...

Страница 13: ...y notice an in dustrial odor the first few fires This is considered normal Use well seasoned wood Open the flue damper to a fully open position Place crumpled or twisted paper under the fireplace grat...

Страница 14: ...ction by qualified technician recommended Check condition of doors surrounds and fronts condition of glass and glass assembly obstructions of combustion and ventilation air obstructions of termination...

Страница 15: ...iner metal shovel fireplace broom WARNING Risk of Fire DO NOT remove ashes until the fire is out and the fireplace is cold Ashes should be placed in metal container with tight fitting lid The closed c...

Страница 16: ...efer to wood fuel section Bed of coals not established before adding wood Start with paper kindling to establish bed of coals refer to starting fire section Flue blockage such as birds nests or leaves...

Страница 17: ...terior factory built chim ney or exterior masonry chimney Try holding a burning rolled up newspaper as close to the flue outlet as pos sible for a few minutes then light the paper under the kindling T...

Страница 18: ...de air closed Overhead fan operating Overhanging tree Bird s nest or leaves in termination cap Structural changes in chimney area Creosote buildup in flue Strong win d s a r o u nd chimney termination...

Страница 19: ...model number and serial number when requesting service parts from your dealer or distributor ITEM DESCRIPTION COMMENTS PART NUMBER 1 Starter Section SRV22069 2 Top Standoff Qty 4 req SRV4044 111 3 Dr...

Страница 20: ...ced SRV19785 Damper Blade 30558 Door Pivot Clip Qty 2 req SRV31527 Firescreen Assembly Qty 2 req 26053 Firescreen Handle Qty 2 req SRV10002 Firescreen Rod Qty 2 req SRV12052 9 Nailing Flange Qty 4 req...

Страница 21: ...erial number when requesting service parts from your dealer or distributor ITEM DESCRIPTION COMMENTS PART NUMBER 1 Starter Section SRV22069 2 Top Standoff Qty 4 req SRV4044 111 3 Drywall Flange 28388...

Страница 22: ...per Blade 30558 Door Pivot Clip Qty 2 req SRV31527 Firescreen Assembly Qty 2 req 29246 Firescreen Handle Qty 2 req SRV10002 Firescreen Rod Qty 2 req SRV4010 102 9 Nailing Flange Qty 4 req 31190 Outsid...

Страница 23: ...Bi fold Glass Doors DM1736 DM1742 Gas Inserts Gas Log Sets Gas Log Lighters Wood burning Inserts Grand Vista Cabinet Style Mesh Door GV36BK GV42BK Majestic Sovereign Series SA36R SA42R Owners Manual...

Страница 24: ...24 This page intentionally left blank Majestic Sovereign Series SA36R SA42R Owners Manual 4010 260 Rev H 1 2020...

Страница 25: ...25 This page intentionally left blank Majestic Sovereign Series SA36R SA42R Owners Manual 4010 260 Rev H 1 2020...

Страница 26: ...1 5941237 5947112 5996575 6006743 6019099 6048195 6053165 6145502 6170481 6237588 6296474 6374822 6413079 6439226 6484712 6543698 6550687 6601579 6672860 6688302 6688302B2 6715724B2 6729551 6736133 67...

Отзывы: