26
Majestic • PEARL36STIN, PEARL36PRIN Installation Manual • 2478-980 Rev. C • 3/17
Figure 4.17
4. Center the exhaust restrictor in the open end of the
exhaust outlet and secure through the slots on the
exhaust restrictor with the 2-1/4 in. self-tapping screws
provided in the appliance manual bag.
5. Reinstall the exhaust baf
fl
e and the refractory panel.
3. Use Table 4.1 to match the amount of vertical you have
in the system to
fi
nd the appropriate position to set the
exhaust restrictor. See Figure 4.17.
1 2 3 4 5
SETTINGS
1 2 3 4 5
Vertical
TOP VENT
REAR VENT
NG
LP
NG
LP
10 ft.
1-1
1-1
1-1
1-1
20 ft.
2-2
2-2
2-2
2-2
30 ft.
2-2
2-2
2-2
2-2
40 ft.
3-3
3-3
3-3
3-3
50 ft.
3-3
3-3
3-3
3-3
60 ft.
3-3
3-3
3-3
3-3
Note
: If the DVP-2SL and DVP-SLP24 adapter and SLP
pipe is used, you MUST subtract one number from the
table above.
Example:
Top vent 60 ft vertical with DVP pipe = 3-3
Top vent 60 ft vertical with SLP pipe = 2-2
Figure 4.16 Exhaust Restrictor
2. Break the exhaust restrictor into two pieces. Do this
by bending the part back and forth until it breaks (see
Figure 4.16).
BREAK
HERE
Table 4.1