Majestic MERCURY MERC32IN Скачать руководство пользователя страница 22

Majestic •  MERC32IN, MERC32IL Owner’s Manual  •  2401-981 Rev. M  •  1/21

22

Service Parts

MERC32

Beginning Manufacturing Date: June 2016 

Ending Manufacturing Date: Active

IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. 

Hearth and 

Home Technologies does not sell directly to consumers

. Provide model number and serial number when 

requesting service parts from your dealer or distributor.

Stocked 

at Depot

ITEM

DESCRIPTION

COMMENTS

PART NUMBER

15.1

Pilot Assembly NG 

2106-169

Y

Pilot Assembly LP

2107-070

Y

Pilot Tube

SRV485-301

Y

15.2

3-Hole Grommet

SRV2118-420

15.3

Valve Bracket 

2118-104

15.4

Flexible Gas Connector  

SRV302-320

Y

15.5

Valve NG 

750-500

Y

Valve LP

750-501

Y

15.6

Thermostat Wire

SRV2118-170

Y

15.7

Module

SRV593-592

Y

15.8

Wire Assembly 

SRV593-590

Y

15.9

Flex Tube Assembly

SRV7000-156

Y

15.10

3 Volt Transformer  

SRV593-593

Y

15.11

Battery Pack 

SRV593-594

Y

15.12

Orifice NG (#45C)

582-845

Y

Orifice LP (#55C)

582-855

Y

15.13

Male Connector

Pkg of 5

303-315/5

Conversion Kit  NG

NGK-3732

Y

Conversion Kit  LP 

LPK-3732

Y

Regulator NG

SRVNGK-DXV

Y

Regulator LP

SRVLPK-DXV

Y

Pilot Orifice NG

SRV593-528

Y

Pilot Orifice LP

SRV593-527

Y

#15 IPI Valve Assembly

15.1

14.13

15.2

15.3

15.4

15.5

15.6

15.7

15.8

15.9

15.10

15.11

15.12

Содержание MERCURY MERC32IN

Страница 1: ...nts for location of additional Commonwealth of Massachusetts requirements Models MERC32IN MERC32IL DO NOT store or use gasoline or other flam mable vapors and liquids in the vicinity of this or any ot...

Страница 2: ...ATURAL TURAL GAS GAS MADE MADE IN IN USA USA Minimum Minimum Permissible Permissible Gas Gas Supply Supply for for Purposes Purposes of of Input Input Adjustment Adjustment Approved Approved Minimum...

Страница 3: ...4 2 Product Specific Information A Appliance Certification 6 B Glass Specifications Tempered 6 C BTU Specifications 6 3 Important Safety and Operating Information A Appliance Safety 7 B General Operat...

Страница 4: ...ed HHT dealer or distributor whichever occurs earlier However the Warranty coverage shall commence no later than 24 months following the date of Product shipment from HHT regardless of the installatio...

Страница 5: ...r handling devices such as exhaust fans or forced air furnaces or other such causes 6 use of fuels other than those specified in the operation instructions 7 installation or use of components not supp...

Страница 6: ...tor to order C BTU Specifications This product is listed to ANSI standards for Vented Gas Fireplace Heaters and applicable sections of Gas Burn ing Heating Appliances for Manufactured Homes and Recrea...

Страница 7: ...models 3 3 Important Safety and Operating Information Clear Space WARNING DO NOT place combustible objects in front of the fireplace or block louvers High temperatures could start a fire See Figure 3...

Страница 8: ...lation site Conversions must be made by a qualified service technician using Hearth Home Technologies specified and approved parts DECORATIVE FRONT SECTION 4 B 6 A FIXED GLASS ASSEMBLY NOT SHOWN SECTI...

Страница 9: ...to model actual TV temperatures should be validated at the me of each installa on TVs should not be used in situa ons where the actual TV temperature exceeds the manufacturers maximum allowable opera...

Страница 10: ...en removed from inside and or underneath the firebox Review proper placement of logs ember material and or other decorative materials Check the wiring Check the air shutter adjustment Ensure that ther...

Страница 11: ...anual 2401 981 Rev M 1 21 F Lighting Instructions Lighting Instructions IPI The IPI system may be operated with two D cell batteries When using batteries unplug the transformer To prolong battery life...

Страница 12: ...burn rate which is controlled by the HI LO knob on the gas valve Therefore the flame height is adjustable The HI LO knob is shown in Figure 3 6 It is located in the control cavity of the appliance Th...

Страница 13: ...battery backup system that supplies power to spark the ignition flame in the event of a power outage IntelliFire is an intermittent pilot ignition which is an electronic system The term Intermittent i...

Страница 14: ...and secure glass latches with the other hand Inspect and operate all glass latches to ensure they move freely and no obstructions are present Reinstall decorative front B Maintenance Tasks Homeowner T...

Страница 15: ...ds Inspect for corrosion or separation Verify weather stripping sealing and flashing remains intact Inspect draft shield to verify it is not damaged or missing C Maintenance Tasks Qualified Service Te...

Страница 16: ...ttery back up IPI systems to prevent premature battery failure or leaking Check for smooth lighting and ignition carryover to all ports Verify that there is no ignition delay Inspect and ensure the li...

Страница 17: ...ld be cleaned within 3 to 4 hours of initial burning to remove deposits left by oils from the manufacturing process A non abrasive cleaner such as gas fireplace glass cleaner may be necessary See your...

Страница 18: ...pilot assembly for shorted sparker wire or cracked insulator around electrode Replace pilot if necessary 2 Pilot won t light there is no noise or spark A No power or transformer installed incorrectly...

Страница 19: ...installed and gas inlet is set to pressure specifications Polish flame sensing rod with fine steel wool to remove any contaminants that may have accumulated on flame sensing rod C Module is not groun...

Страница 20: ...uestions Install approved accessories per instructions included with accessories Contact your dealer for a list of ap proved accessories WARNING Risk of Fire and Electric Shock Use ONLY Hearth Home Te...

Страница 21: ...Log 6 SRV2397 705 7 Burner Assembly 2355 007 Y 8 Base Pan 2355 110 9 Glass Door Assembly GLA 550TR Y 10 Fire Screen Front SRV2401 021 Y 11 Hood 2115 230 12 Drywall Support 2391 119 13 Junction box SR...

Страница 22: ...Y Pilot Tube SRV485 301 Y 15 2 3 Hole Grommet SRV2118 420 15 3 Valve Bracket 2118 104 15 4 Flexible Gas Connector SRV302 320 Y 15 5 Valve NG 750 500 Y Valve LP 750 501 Y 15 6 Thermostat Wire SRV2118 1...

Страница 23: ...MENTS PART NUMBER 16 1 Pilot Assembly NG 2103 010 Y Pilot Assembly LP 2103 011 Y Pilot Tube SRV485 301 Y 16 2 3 Hole Grommet SRV2118 420 16 3 Valve Bracket 2118 104 16 4 Flexible Gas Connector SRV302...

Страница 24: ..._______________________________________ ________________________________________________________________________________ DO NOT DISCARD THIS MANUAL NOTICE Leave this manual with party responsible for...

Отзывы: