Majestic MARQ42STIN Скачать руководство пользователя страница 30

Majestic  •  MARQ42STIN Owner Manual  •  2272-981 Rev. J •  7/18 

30

HOT

This indicates that the appliance is still hot, when the 
appliance is off.

Remote Control 
Battery

Remote control battery life indicator. If the batteries on 

your  remote  are  low,  a  notification  will  display  on  the 

screen asking you to ‘replace remote batteries’.

Refer to Replace Remote Batteries Section.  

Backup Battery

The battery life indicator is for a backup power source 
located inside your appliance.  It is intended to operate 
the appliance in the event of a power failure.  Consult 
your owner’s manual for your appliance on how to utilize 
this feature.

Batteries  should only be used as an appliance power 
source in the event of a power outage. Batteries should 
not be used as a primary long-term power source. 

Note:

  Battery backup is not available if a Power Vent is 

installed.

INDICATORS

Cold Climate

This function turns on a small pilot flame and keeps the 

air inside your appliance warm while not in use. It is a 
useful feature in colder weather to minimize condensa-
tion on the appliance glass.  

Note:

  This feature is disabled when a Power Vent is 

installed on the appliance.

Temperature Display

You can toggle the temperature display between °F and 

°C by tapping on the Room Temperature area.

Lights*

If your appliance is equipped with lighting features, use 
this function to adjust them to your desired intensity.  The 

lights can be adjusted whether the flame is on or off.

* = Optional Feature

Power Vent*

Power Vent technology makes it possible to install a gas 
appliance virtually anywhere.  The Power Vent is a fan 
powered accessory that pulls exhaust from the appliance 

providing longer and more flexible venting configurations. 

A Power Vent is a standard accessory on some products 
and an option on others.  When a Power Vent is detected, 

a  pre-purge  of  120  seconds  is  automatically  required.  

During this time, the power icon is temporarily replaced 

with 2MIN, 90s, 60s, and 30s, denoting the countdown 

until the appliance turns on.  All other functions, except 
for TURN FLAME OFF are disabled during this time.

  

The Power Vent is always ON when the flame is ON.  
When  the  flame  is  turned  off,  a  post-purge  time  of 

approximately 20 minutes will occur.

 
Cold-climate function and battery backup are disabled if 
a Power Vent is used.

FUNCTIONS

Fan Speed*

If your appliance is equipped with the fan feature, use 
this function to increase or decrease the amount of heat 
released into your room.  A built-in delay timer will turn 
the fan on three minutes after your appliance has been 
running to prevent cool air from being pushed into the 

room. If the flame is turned off with the fan ON, the fan 

will continue to run for 12 minutes then shutdown as long 

as the flame stays off. 

Your appliance will remember the previous fan speed 

setting and automatically adjust to that level 10 seconds 

after start-up.

Diagnostics Menu

Tap anywhere in the gray indicator bar area to display all 
functions below.  When red, it indicates an error has been 
detected.

Timer

For your convenience a timer can be set up to 180 min

-

utes to turn off your appliance. The timer will turn the 

flame off automatically at the selected preset time.  

 
To use the timer function, press “Timer” on the main 
screen, select time by using up and down arrows, then 
press “on”.  To turn the timer off , select timer from main 
screen and select “off”.

Child Lock

A child lock is available underneath the battery cover.  When 
the lock is enabled, the screen will lock and no functions can 
be selected.  The lock icon will appear on the remote control.

Содержание MARQ42STIN

Страница 1: ...licensed plumber or gas fitter See appliance installation manual for additional Commonwealth of Massachusetts requirements DANGER HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLO...

Страница 2: ...TURAL TURAL GAS GAS MADE MADE IN IN USA USA Minimum Minimum Permissible Permissible Gas Gas Supply Supply for for Purposes Purposes of of Input Input Adjustment Adjustment Approved Approved Minimum Mi...

Страница 3: ...ety and Operating Information A Appliance Safety 7 B General Operating Parts 8 C Fuel Specifications 8 D Good Faith Wall Surface TV Guidelines 8 E Before Lighting Appliance 10 F Lighting Instructions...

Страница 4: ...date of original purchase In the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent aut...

Страница 5: ...CLUSIONS This warranty does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occ...

Страница 6: ...ble sections of Gas Burn ing Heating Appliances for Manufactured Homes and Recreational Vehicles and Gas Fired Appliances for Use at High Altitudes MODELS MARQ42STIN LABORATORY Underwriters Laboratori...

Страница 7: ...h children to NEVER touch the fireplace Consider not using the fireplace when children will be present Contact your dealer for more information or visit www hpba org Product Info Fireplace Stove Heate...

Страница 8: ...e sure the appliance is compatible with gas type selected for installation site Conversions must be made by a qualified service technician using Hearth Home Technologies specified and approved parts F...

Страница 9: ...odel to model actual TV temperatures should be validated at the me of each installa on TVs should not be used in situa ons where the actual TV temperature exceeds the manufacturers maximum allowable o...

Страница 10: ...emoved from inside and or underneath the firebox Review proper placement of logs ember material and or other decorative materials Check the wiring Check the air shutter adjustment Ensure that there ar...

Страница 11: ...mmediately call your gas supplier from a neighbor s phone Follow the gas sup plier s instructions C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push...

Страница 12: ...y See Section 4 B Clean fixed glass assembly See Section 4 B Replace the fixed glass assembly and run continuously on high an additional 12 hours NOTICE In some cases residue may appear on the top fib...

Страница 13: ...ttery tray and insert four AA cell batteries Battery polarity must be correct or module damage will occur See Figure 3 5 A complete wiring diagram is included in the Electrical section of the applianc...

Страница 14: ...setting No adjustment in flame height is possible Remote Position The remote position allows operation of the appliance from a wired wall switch IFT RC400 or IFT RC150 remote controls The IFT ECM swi...

Страница 15: ...ON Risk of burns Appliance surfaces are hot when operating and during cool down Use care and wear gloves when opening the front and accessing com ponents inside the appliance Be aware the appliance ma...

Страница 16: ...frequent cleaning may be required due to excessive lint from carpeting bedding material et cetera It is im perative that control compartments burners and circulat ing air passageways of the appliance...

Страница 17: ...not using your fireplace for an extended period of time summer months vacations trips etc to prevent unin tended operation Remove batteries from remote controls Unplug 6 volt adapter plug on IPI mode...

Страница 18: ...ean glass with a non abrasive commercially available cleaner Light deposits Use a soft cloth with soap and water Heavy deposits Use commercial fireplace glass cleaner consult with your dealer Carefull...

Страница 19: ...ize pieces DO NOT block ports or obstruct lighting paths Refer to appliance installation manual for proper ember placement Verify batteries have been removed from battery back up IPI systems to preven...

Страница 20: ...ating duct This noise does not affect the operation or longevity of the fireplace Is it normal to see the pilot flame burn continually In an intermittent pilot ignition system IPI the pilot flame shou...

Страница 21: ...of it The remote acts as the thermostat Remote is placed in the path of an air draft or vent Move the remote away from the direct path of air flow The remote acts as the thermostat Flame Modulation Th...

Страница 22: ...h is in ON or IFT REM position Verify AC power available to junction box Verify AC DC adap tor is plugged into junction box and ECM Verify AC DC adaptor output voltage is between 5 7 6 3 Vdc If batter...

Страница 23: ...ve solenoid Check main valve solenoid resistance nominal is 60 ohms If open or shorted replace valve Verify valve inlet pressure is correct for gas type Pilot and main do not light ECM goes into 5 Red...

Страница 24: ...Keep remote controls out of reach of children See your dealer if you have questions Optional Heat Zone Gas Kit After a qualified service technician has installed the Heat Zone Gas Kit follow the instr...

Страница 25: ...ce Parts Beginning Manufacturing Date Oct 2016 Ending Manufacturing Date Active MARQ42STIN 1 2 3 4 5 6 7 8 9 10 11 Marquis 42 See Through Gas Fireplace DV Log Set Assembly Part number list on followin...

Страница 26: ...RV2272 707 9 Log Replacement SRV2272 708 10 Log Replacement SRV2272 708 11 Log Replacement SRV2272 709 12 Light Box Mesh Assembly Qty 2 req 2146 016 13 Non combustible Board Qty 2 req 2146 051 14 Fini...

Страница 27: ...Y 23 3 Valve Bracket 2146 192 23 4 Wire Harness SRV2326 132 Y 23 5 Side Panel Bracket 2146 150 23 6 Grommet SRV2118 420 23 7 Pilot Assembly NG 2457 020 Y Pilot Assembly Propane Convert 2457 020 with S...

Страница 28: ...ell directly to consumers Provide model number and serial number when requesting service parts from your dealer or distributor Stocked at Depot ITEM DESCRIPTION COMMENTS PART NUMBER 24 Refractory Kit...

Страница 29: ...from the appliance adjacent windows and doors HVAC vents and direct sunlight To use the thermostat function access the main menu screen on your remote and select thermostat Next simply select your des...

Страница 30: ...venting configurations A Power Vent is a standard accessory on some products and an option on others When a Power Vent is detected a pre purge of 120 seconds is automatically required During this time...

Страница 31: ...nder If the remote 300 hour maintenance message does not clear on the first try repeat above steps INDICATORS Your appliance has been disabled Please contact your dealer and report this issue Call Dea...

Страница 32: ...______________________________________ ________________________________________________________________________________ ________________________________________________________________________________...

Отзывы: