C.  BTU Specifications

This product is listed to ANSI standards for “Vented Gas 

Fireplace Heaters” and applicable sections of “Gas Burn-

ing Heating Appliances for Manufactured Homes and 

Recreational Vehicles”, and “Gas Fired Appliances for 

Use at High Altitudes”.

A.  Appliance Certification

NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.  

This appliance is tested and approved as either supplemen-

tal room heat or as a decorative appliance.  It should not be 

factored as primary heat in residential heating calculations.

NOTICE: This installation must conform with local codes. 

In the absence of local codes you must comply with the 

National Fuel Gas Code, ANSI Z223.1-latest edition in 

the U.S.A. and the CAN/CGA B149 Installation Codes in 

Canada.

Product Specific Information 

 

B.  Glass Specifications

This appliance is equipped with 5 mm ceramic glass with 

an anti-reflective coating. Replace glass only with glass 

with identical specifications.  Please contact your dealer 

for replacement glass.

MODELS:  MARQ36IN, MARQ42IN

LABORATORY:  Underwriters Laboratories, Inc. (UL)

TYPE:  Direct Vent Heater

STANDARD: ANSI Z21.88-2014 • CSA 2.33-2014

Models

(U.S. or Canada)

Maximum

Input 

BTU/h

Minimum

Input 

BTU/h

Orifice

Size 

(DMS)

MARQ36IN (NG)

(0-2000 FT)

44,000

25,000

#30

MARQ36IN (LP)

(0-2000 FT)

43,500

24,000

#47

MARQ42IN (NG)

(0-2000 FT)

54,500

30,000

#26

MARQ42IN (LP)

(0-2000 FT)

47,500

23,500

#45

Installation and service of this 

appliance should be performed 

by qualified personnel. Hearth & 

Home Technologies recommends 

NFI certified professionals.

Содержание MARQ36IN

Страница 1: ...dealer with questions regarding installation operation or service DANGER HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS A barrier designed to reduce th...

Страница 2: ...NA ATURAL TURAL GAS GAS MADE MADE IN IN USA USA Minimum Minimum Permissible Permissible Gas Gas Supply Supply for for Purposes Purposes of of Input Input Adjustment Adjustment Approved Approved Minimu...

Страница 3: ...BTU Specifications 6 3 Important Safety and Operating Information A Appliance Safety 7 B General Operating Parts 8 C Fuel Specifications 8 D Good Faith Wall Surface TV Guidelines 9 E Before Lighting...

Страница 4: ...the date of original purchase In the case of new home construction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent...

Страница 5: ...Y EXCLUSIONS This warranty does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may...

Страница 6: ...he National Fuel Gas Code ANSI Z223 1 latest edition in the U S A and the CAN CGA B149 Installation Codes in Canada 2 Product Specific Information B Glass Specifications This appliance is equipped wit...

Страница 7: ...front of the fireplace or block louvers High temperatures may start a fire See Figure 3 1 Avoid placing candles and other heat sensitive objects on mantel or hearth Heat may damage these objects Figur...

Страница 8: ...ecified and approved parts FIXED GLASS ASSEMBLY NOT SHOWN SECTION 4 B 4 C LED REPLACEMENT SECTION 4 C MANTEL CLEAR SPACE SECTION 3 A RATING PLATE GLASS CLIP TOOL LOCATION SECTION 3 B OPERATION DURING...

Страница 9: ...WARNING Risk of Fire or Asphyxiation DO NOT op erate fireplace with fixed glass assembly removed MEASUREMENTS FROM TOP EDGE OF THE OPENING 22 IN 34 IN 40 IN 46 IN 52 IN MIN CEILING 28 IN APPLIANCE FRO...

Страница 10: ...rom model to model actual TV temperatures should be validated at the me of each installa on TVs should not be used in situa ons where the actual TV temperature exceeds the manufacturers maximum allowa...

Страница 11: ...nce Hot while in operation DO NOT touch Keep children clothing furniture gasoline and other liquids having ammable vapors away DO NOT operate the appliance with xed glass assembly removed cracked or b...

Страница 12: ...ction 4 B Clean fixed glass assembly See Section 4 Replace the fixed glass assembly and run continuously on high an additional 12 hours This cures the materials used to manufacture the fire place NOTI...

Страница 13: ...Locate the battery tray and insert four AA cell batteries Battery polarity must be correct or module damage will occur See Figure 3 5 A complete wiring diagram is included in the Electrical section o...

Страница 14: ...omatically shut down the fireplace after 9 hours of continuous operation without receiving a command from the IFT RC400 or IFT RC150 2 If multiple control options are installed the IFT ECM will respon...

Страница 15: ...and during cool down Use care and wear gloves when opening the front and accessing compo nents inside the appliance Be aware the appliance may be HOT use care in accessing the IFT ECM Set the IFT ECM...

Страница 16: ...sess condition of screen and replace as necessary Inspect for scratches dents or other damage and repair as necessary Check that louvers are not blocked Vacuum and dust surfaces Remote Control Frequen...

Страница 17: ...th care Glass is breakable Avoid striking scratching or slamming glass Avoid abrasive cleaners DO NOT clean glass while it is hot NOTICE Use only glass cleaner compatible with ce ramic glass Other typ...

Страница 18: ...emove the ember glass assembly The LED box can be lifted out of the fireplace at this point See replacement parts list for LED part numbers Burner Ignition and Operation Frequency Annually By Qualifie...

Страница 19: ...and adhesives used around the fireplace Film on the glass This is a normal result of the curing process of the paint and logs Glass should be cleaned within 3 to 4 hours of initial burning to remove...

Страница 20: ...ront of it The remote acts as the thermostat Remote is placed in the path of an air draft or vent Move the remote away from the direct path of air flow The remote acts as the thermostat Flame Modulati...

Страница 21: ...witch is in ON or IFT REM position Verify AC power available to junction box Verify AC DC adap tor is plugged into junction box and ECM Verify AC DC adaptor output voltage is between 5 7 6 3 Vdc If ba...

Страница 22: ...valve solenoid Check main valve solenoid resistance nominal is 60 ohms If open or shorted replace valve Verify valve inlet pressure is correct for gas type Pilot and main do not light ECM goes into 5...

Страница 23: ...ls out of reach of children See your dealer if you have questions Optional Heat Zone Gas Kit An optional Heat Zone Kit is available for your appli ance It must be installed by a qualified service tech...

Страница 24: ...SRV2270 702 3 Log 3 SRV2270 703 4 Log 4 SRV2270 704 5 Log 5 SRV2270 706 6 Log 6 SRV2271 705 7 Log 7 SRV2271 707 8 Heat Shield Header Qty 2 req 2280 105 9 Heat Shield Valve 2281 153 10 Junction box 40...

Страница 25: ...2 Log 2 SRV2271 702 3 Log 3 SRV2271 703 4 Log 4 SRV2271 704 5 Log 5 SRV2271 705 6 Log 6 SRV2271 706 7 Log 7 SRV2271 707 8 Heat Shield Header Qty 2 req 2281 105 9 Heat Shield Valve 2281 153 10 Junctio...

Страница 26: ...03 315 5 Y 13 5 Valve NG 2166 302 Y Valve LP 2166 303 Y 13 6 Flex Ball Valve Assembly 12 302 320A Y 13 7 Rocker Switch 2206 299 Y 13 8 Grommet 2118 420 13 9 Wire Battery jumps 10 in 2281 196 Y 13 10 B...

Страница 27: ...714 21 8 Refractory Back SRV2270 715 Refractory Herringbone BRICKMQ36HB 22 1 Refractory Top SRV2270 726 22 2 Refractory Left SRV2270 723 22 3 Refractory Left Base SRV2270 728 22 4 Refractory Left Base...

Страница 28: ...SRV2271 714 21 8 Refractory Back SRV2271 715 Refractory Herringbone BRICKMQ42HB 22 1 Refractory Top SRV2271 726 22 2 Refractory Left SRV2271 723 22 3 Refractory Left Base SRV2271 728 22 4 Refractory...

Страница 29: ...2 req 2146 413 Y Glass Latch Assembly MARQ36 Qty 3 req 2155 045 Y MARQ42 Qty 4 req Kapton Lens Light Orange Qty 2 req 2166 171 Y Lava Rock 4021 296 Mineral Wool 050 721 Nut 1 4 20 Hex Insert 7000 236...

Страница 30: ...eat from the appliance adjacent windows and doors HVAC vents and direct sunlight To use the thermostat function access the main menu screen on your remote and select thermostat Next simply select your...

Страница 31: ...ble venting configurations A Power Vent is a standard accessory on some products and an option on others When a Power Vent is detected a pre purge of 120 seconds is automatically required During this...

Страница 32: ...reminder If the remote 300 hour maintenance message does not clear on the first try repeat above steps INDICATORS Your appliance has been disabled Please contact your dealer and report this issue Call...

Страница 33: ...______________________________________________ ________________________________________________________________________________ ________________________________________________________________________...

Отзывы: