![Majestic JADE32IN-B Скачать руководство пользователя страница 15](http://html2.mh-extra.com/html/majestic/jade32in-b/jade32in-b_owners-manual_4092264015.webp)
15
Majestic • JADE32IN-B, JADE42IN-B, JADE42IL-B Owner Manual • 2619-987 Rev. B • 10/19
H. Appliance Break-In
Follow the initial break-in procedure below to cure the
materials used to manufacture the fireplace and the
finishing materials around it.
• The fireplace should be run three to four hours
continuously on high.
• Turn the fireplace off and allow it to cool completely.
• Remove fixed glass assembly. See Section 4.B.
• Clean fixed glass assembly. See Section 4.B.
• Replace the fixed glass assembly and run continuously
on high an additional 6-12 hours.
Note:
Some IPI systems have a safety feature that
automatically shuts down the fireplace after 9 hours of
continuous operation without receiving a command from
the remote control. If this occurs, restart the appliance.
NOTICE!
Open windows for air circulation during fire
-
place break-in.
• Some people may be sensitive to smoke and odors.
• Smoke detectors may activate.
Optional Heat-Zone
®
-Gas Kit
The HEAT-ZONE
®
-GAS heat management option is avail-
able for use with the JADE32IN-B/JADE42IN-B/JADE-
42IL-B appliances and must be used in conjunction with
the IFT-RC400 control. The Heat-Zone Kit draws heat
from your fireplace to an adjacent room in your home, up
to 20 feet away.
Optional Heat-Out-Gas Kit
The HEAT-OUT-GAS heat management option is available
for use with the JADE32IN-B/JADE42IN-B/JADE42IL-B
appliances
and is operated with a wall switch. The Heat-
Out-Gas kit draws heat from your fireplace and directs it
outside, up to 25 feet away.
Optional Smart-Wall™ TV Kit
The Smart-Wall™ TV Kit heat management option is
available for use with the JADE32IN-B/JADE42IN-B/
JADE42IL-B appliances. Safely place a TV 12 inches
above the fireplace. The Smart-Wall™ TV kit must be
used in conjunction with the IFT-RC400 remote control.
The Smart-Wall™ TV kit is not compatible with a power
vent, fan or passive heat.
Optional Passive Heat Kit (PH-FRT/PH-SIDE)
The Passive Heat heat management option is available
for use with the JADE32IN-B/JADE42IN-B/JADE42IL-
B appliances. The Passive Heat Kit allows the heat to
be vented into the room through one front discharge, two
side discharges or an open top discharge while the fire
-
place is in operation. Passive Heat can be used in con-
junction with HEAT-ZONE
®
-GAS or HEAT-OUT-GAS
kit.
Passive Heat is not compatible with optional fan kit.
I. Heat Management
Heat Output
• Change hi/lo setting on valve
• Change fan speed
Burn Rate
The JADE32IN-B/JADE42IN-B/JADE42IL-B models
have a variable burn rate which is controlled by the
remote control. Therefore the flame height is adjustable.
The flame height may be adjusted as desired by locating
the flame option on the remote control and adjusting up or
down to desired flame height.
An optional heat management system, which allows the
heat from the appliance to be redirected as desired, may
be installed with this appliance. It may be either a Heat-
Zone
®
-Gas, which diverts heat into an adjacent room,
and/or a HEAT-OUT-GAS which will divert heat outside
the home/building, a Smart-Wall™ TV Kit, which allows
you to bring the warmth from your fireplace to the rest
of your home, up to 20 feet away, and/or a Passive Heat
kit which disperses the heat into the same room as the
fireplace.
Refer to Section 6 of the appliance installation manual to
confirm which of the heat management systems may be
installed together. All heat management systems must
be installed by a qualified service technician at the time of
appliance installation.
Optional Heat Management Systems