To avoid personal injury or property damage, the product described by this brochure must be installed, operated and maintained in strict compliance with the instructions packaged with the product and all applicable

building or fire codes. Contact local building or fire officials about restrictions and installation inspection requirements. All photographs and drawings on this brochure are for illustrative purposes only and are

not intended for, nor should they be used as a substitute for the instructions packaged with the unit. Appearance and specifications of the product are subject to change without notice. 12/10 ver.1

HPBA

Hearth, Patio&BarbecueAssociation

MADE IN U.S.A.

A Brand of Monessen Hearth Systems Co.

149 Cleveland Drive, Paris, Kentucky 40361

www.majesticproducts.com

P RO D U C T S PE C I F I C AT I O N S

CDVR33SC7 Direct Vent

T E C H N I C A L S P E C I F I C AT I O N S

BTU Input:

18,000 Max, 13,000 Min. (Nat) / 18,000 Max, 13,000

Min. (LP)

Ignition System:

Signature Command System (AC w/ battery back up)

Gas Type:

Natural Gas or Liquid Propane

Gas Line:

18” (473 mm) Flex line w/ shut off 1/2” (12.7 mm) FPT

Flue Type:

4 x 7 Twist Lock, Flex Vent*

Termination:

Dedicated Rear Vent

Horizontal Vent:

Maximum 20” (508 mm) straight off rear of unit

Low Voltage Wall Switch Wire:

15' (4.5 m) wire with wall switch

and cover

Design Certified:

CSA

C L E A R A N C E T O F L U E

Horizontal:

3” (26 mm) Top, 1” (25 mm) Bottom and sides**

Vertical:

1” (25 mm) on all sides

C L E A R A N C E T O C O M B U S T I B L E S

Fireplace:

0” Clearance to stand offs all sides

Floor of unit to Ceiling:

72” (1.83 m) to Combustibles

Firebox Opening to Wall:

6” (152 mm) to Combustibles

Hearth Requirement:

0” Clearance

E F F I C I E N C Y D ATA

Thermal Efficiency:

Up to 80% Nat / 80% LP

AFUE Efficiency:

61.2% Nat / 66.3% LP

P4 Canada Efficiency:

57.6% Nat / 64.3% LP

*Simpson Dura-Vent, Selkirk Metalbestos and Metalfab are also approved for vent ap-

plications (requires adapter).

**When vertical rise is 7-1/2 feet (2.29 m) or higher from base of unit, the horizontal

vent clearance to combustibles is 1" (25 mm) all sides.

12” (305 mm)

8” (203 mm)
6” (152 mm)

2-1/2” (64 mm)

14” (356 mm)
11” (279 mm)

10” (254 mm)
  8” (203 mm)

Finish Wall

Header

Stud

Standoff

Top of Heat 

Exhaust Vent

FP2285b

Side View

Front View

6

(152 mm)

5

(127 mm)

3

(76 mm)

45°

1

(25 mm)

2-1/2” (64 mm)

1-1/2” (38 mm)

3-1/2” (89 mm)

4-1/2” (114 mm)

Side of Fireplace 

Opening

Stud

Wall

FP2286

Combustible 

Material Area

M A N T E L C L E A R A N C E S

NOTE:

The combustible area above the facing must not protrude
more than 3/4” (19 mm) from the facing. If it does, it is consid-
ered a mantel and must meet the mantel requirements listed
here.