Majestic ASH42 Скачать руководство пользователя страница 18

18

A. FAQs

If smoke spillage occurs from a fireplace opening when 

the door is open, there is either a leakage in the flue, a 

blockage in the flue, or some condition is affecting draft 

Understanding and differentiating the conditions which 

can cause each of these kinds of spillage problems is 

essential to their solution.

•  Flue Leakage

  Check  for  improperly  connected  flue  joints  or  a 

damaged  flue  joint  in  the  chimney  system.  Such 

leakage would reduce draft (air would be drawn in 

through the leaks rather than through the fireplace). 

The  result  might  be  difficult  start-up  and  smoky 

fires that might spill if other adverse draft conditions 

accompany this problem.

•  Flue Blockage

  The damper should be open.

  Check  for  objects  that  may  have  fallen  down  the 

chimney.

erating instructions, “Starting a Fire”. Be sure your flue 

system is installed correctly and that it is the proper di

-

ameter and height. Check for the following:

•  All chimney sections are properly installed.

•  The chimney is clean and free of creosote or soot 

buildup.

•  Make sure overhanging trees and branches are cut 

back within ten feet of the top of the chimney and the 

chimney is free of debris from animals.

•  Ensure  the  chimney  cap  is  clean  and  free  of  any 

buildup of soot or creosote if cap is equipped with a 

spark arrestor screen.

•  The wood being used in dry and well seasoned.

If you still suspect you have a low draft problem it may 

be  necessary  to  increase  the  volume  of  air  in  your 

flue system. Since the diameter of your flue system is 

matched with the size of the flue collar and should not 

be changed, then the height of the system must be in

-

creased. Add chimney sections one at a time until the 

draft improves.
In some cases, regardless of what you do, it can still be 

difficult to establish the proper flue draft. This is espe

-

cially evident when using an exterior factory-built chim

-

ney or exterior masonry chimney. Try holding a burning 

rolled up newspaper as close to the flue outlet as pos

-

sible for a few minutes, then light the paper under the 

kindling. The heat generated from the burning rolled up 

newspaper should help get the draft established. 
Still other factors can affect how well your flue system 

performs. Neighboring structures, high winds, tall trees, 

even hillsides can affect air currents around the chim

-

ney. Well designed chimney caps are available that can 

help. Your  fireplace  dealer  is  the  local  expert  in  your 

area.  He  can  usually  make  suggestions  or  discover 

problems  that  can  be  easily  corrected  allowing  your 

fireplace to operate correctly as it has been designed, 

providing safe and economical heat for your home.

Flue  draft  is  measured  as  negative  pressure  in  the 

chimney. The amount of negative pressure determines 

how strong the draft is. The draft is important because 

it draws the combustion air into the fireplace and pulls 

the smoke out of the chimney. 
There are three basic criteria essential in establishing 

and maintaining flue draft:

•  availability of combustion air

•  heat generated from the fire

•  diameter and height of the flue system

These three factors work together as a system to create 

the flue draft. Increasing or decreasing any one of them 

will affect the other two and thus change the amount of 

draft in the entire system.
If the fire is hard to start and smoke spills out of the fire

-

place, or you find it difficult to establish and maintain a 

moderately high burn rate, then the flue draft is too low 

and corrective measures must be taken. 
Be sure you have air available for combustion and that 

your firewood is dry and well seasoned. Build your fires 

properly and according to the instructions given in op

-

Hearth & Home Technologies assumes no responsibil

-

ity for the improper performance of the fireplace sys

-

tem caused by inadequate draft due to environmental 

conditions,  down  drafts,  tight  sealing  construction  of 

the structure, or mechanical exhausting devices which 

will create a negative air pressure within the structure 

where the fireplace is located.

Contact your dealer for additional informa-

tion regarding operation and troubleshoot-

ing. Visit www.vermontcastingsgroup.com 

to find a dealer.

Majestic Ashland Series • ASH42  OWNERS MANUAL • 4059-916 • Rev E • 01/2020

Содержание ASH42

Страница 1: ...glass Keep children away CAREFULLY SUPERVISE children in same room as fireplace Alert children and adults to hazards of high temperatures High temperatures may ignite clothing or other flammable mater...

Страница 2: ...Important Safety and Operating Information A Fireplace Safety 7 1 Clear Space 7 2 Grate 8 3 Molded Brick Panel 8 4 Firescreen 8 5 Flue Damper 8 6 Glass Doors 8 7 Over Firing Your Fireplace 8 8 Chimney...

Страница 3: ...______________________________________ ____________________________________________________________ Phone _____________________________________________________________ E mail _________________________...

Страница 4: ...ter than 24 months following the date of product shipment from HHT regardless of the installa on or occupancy date The warranty period for parts and labor for covered components is produced in the fol...

Страница 5: ...ued opera on with damaged corroded or failed components accident or improperly incorrectly performed repairs 5 environmental condi ons inadequate ven la on nega ve pressure or dra ing caused by ghtly...

Страница 6: ...eparately and in stalled at a later date An outside air kit gas log set gas insert or gas log lighter should be installed at the time of fireplace installation This fireplace system has been tested an...

Страница 7: ...curtains chairs or other combustibles must be at least 4 ft 1219 mm from the front of the fireplace Combustible materials are materials made of or sur faced with any of the following materials Wood Co...

Страница 8: ...integral grate Keeps logs in place Allows proper air circulation around the fire 3 Molded Brick Panel The molded brick panel is shipped separately but required to contain heat and provide an attracti...

Страница 9: ...d NEVER allow children to touch glass Keep children away CAREFULLY SUPERVISE children in same room as fireplace Alert children and adults to hazards of high temperatures High temperatures may ignite c...

Страница 10: ...Figure 3 3 Operating Positions of Bi fold Doors 2 Outside Air Refer to Figure 3 2 for location and operation of control The outside air kit supplies some combustion air for your fireplace It may help...

Страница 11: ...can use the softwood for starting the fire giv ing off quick heat to bring the fireplace up to operating temperature Add the hardwood for slow even heat and longer burn time 2 Moisture content The maj...

Страница 12: ...The time it takes to season wood varies from around nine months for soft woods to as long as eighteen months for hardwoods The key to seasoning wood is to be sure it has been split exposing the wet in...

Страница 13: ...u may notice an industrial odor the first few fires This is considered normal Use well seasoned wood Open the flue damper to a fully open position Place crumpled or twisted paper under the fireplace g...

Страница 14: ...Sweep Confirm that termination cap remains clear and unobstructed Inspect for blockages such as bird nests leaves etc Inspect for corrosion or separation Inspect for creosote and remove as needed at l...

Страница 15: ...ignited this creosote makes an extremely hot fire Remove all ash from the firebox and extinguish all hot embers before disposal Allow the fireplace to cool completely Close the door tightly Remove th...

Страница 16: ...ntil the fire is out and the fireplace is cold Ashes should be placed in metal container with tight fitting lid The closed container of ashes should be placed on a noncombustible floor or on the groun...

Страница 17: ...on Bed of coals not established before adding wood Start with paper kindling to establish bed of coals refer to starting fire section Flue blockage such as birds nests or leaves in termination cap Hav...

Страница 18: ...light the paper under the kindling The heat generated from the burning rolled up newspaper should help get the draft established Still other factors can affect how well your flue system performs Neigh...

Страница 19: ...utside air closed Overhead fan operating Overhanging tree Bird s nest or leaves in termination cap Structural changes in chimney area Creosote buildup in flue Strong win d s a r o u nd chimney termina...

Страница 20: ...m your dealer or distributor ITEM DESCRIPTION COMMENTS PART NUMBER 1 Transition Assembly 4059 044 2 Outer Transiton Assembly 24377 3 Inner Transiton Collar 4059 148 4 Damper Blade Assembly 4059 030 5...

Страница 21: ...060 Mortar 10 Lb Bucket MMMORTR Outside Air Hood Qty 2 req SRV4059 051 Strip Protector SRV18320 Owners Manual 4059 916 Installation Manual 4059 915 Traditional Refractory AMMTB42 13 Left Panel SRV405...

Страница 22: ...as Inserts 3 Gas Log Sets 4 Gas Log Lighters 5 Wood burning Inserts DFG4042 Series Glass Bi fold Doors optional DFS4042 Series Mesh Cabinet Style Doors optional Majestic Ashland Series ASH42 OWNERS MA...

Страница 23: ...23 This page intentionally left blank Majestic Ashland Series ASH42 OWNERS MANUAL 4059 916 Rev E 01 2020...

Страница 24: ...1661 5941237 5947112 5996575 6006743 6019099 6048195 6053165 6145502 6170481 6237588 6296474 6374822 6413079 6439226 6484712 6543698 6550687 6601579 6672860 6688302 6688302B2 6715724B2 6729551 6736133...

Отзывы: